| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 1350-S759 | 3 - Design Control Reference | 9 - No Longer Used | HI-G CO INC | 02289 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 011416697 | A03300 | 32512 | X | 4 | 6 | A | N | U | 3 Nov 1982 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| YA01 | 1 Oct 2000 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 9 | 2 | 9Z | D | 1350-S759 | 02289 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 3 Nov 1982 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZF |
France
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CRNG | Nonpile-Up Main Contact Arrangement | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 30.0 DC |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 1.0 AMPERES DC RESISTIVE LOAD |
| TTQY | Terminal Type And Quantity | 4 WIRE HOOK ALL FUNCTIONS |
| ABHP | Overall Length | 1.750 INCHES NOMINAL |
| ABMK | Overall Width | 1.250 INCHES NOMINAL |
| ABKW | Overall Height | 2.625 INCHES NOMINAL |
| AXHR | Mounting Facility Type And Quantity | 4 THREADED STUD SINGLE MOUNTING FACILITY |
| CQYJ | Mounting Facility Pattern | RECTANGULAR SINGLE MOUNTING FACILITY |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| THSD | Thread Series Designator | UNC SINGLE MOUNTING FACILITY |
| CQJX | Nominal Thread Size | 0.138 INCHES SINGLE MOUNTING FACILITY |
| AAJD | Thread Class | 2A SINGLE MOUNTING FACILITY |
| AASA | Thread Length | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AAJF | Thread Direction | RIGHT-HAND SINGLE MOUNTING FACILITY |