5945-01-142-2180

RELAY,ELECTROMAGNETIC


5945-01-142-2180 (5945011422180, 011422180)
Part Number (1 listing): 7012PCL
Summary

FSG 59 / FSC 5945

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 13 Nov 1982

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5945-01-142-2180 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7012PCL3 - Design Control Reference2 - Production ItemTYCO ELECTRONICS/AGASTAT RELAYS  89020    CAGE 89020  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5945-01-142-2180 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595945011422180A0330032512X1ANU13 Nov 1982
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5945

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Relays and Solenoids

011422180

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5945-01-142-2180

A03300

Federal Item Identification Guide (FIIG_4065)

32512

Item Naming Code (INC_4080)

13 Nov 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5945-01-142-2180 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5945-01-142-2180 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ETX7012PCL  89020   CAGE/89020
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5945-01-142-2180 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597613 Nov 1982
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

13 Nov 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5945-01-142-2180 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
YK
Code Definitions

YK

Originating Activity Code (ORIG_ACTY_CD_4210)


Kuwait

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5945-01-142-2180 Submit RFQ
MRCDecoded RequirementClear Text Reply
APNPDuty TypeCONTINUOUS
APNQArc Quenching MethodAIR
CWGMAuxiliary Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD
CSQCAuxiliary Contact Maximum Voltage Rating In Volts480.0 AC
ADTVCase MaterialPLASTIC
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.750 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.500 INCHES NOMINAL SECOND MOUNTING FACILITY
AEBWCenter To Center Distance Between Mounting Facilities Parallel To Height0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.880 INCHES NOMINAL FIRST MOUNTING FACILITY
APCNCoil Quantity1
CWJBEnergizing Element Power Rating8.0 WATTS
ADZCEnvironmental ProtectionDUSTPROOF
AFJNFragility FactorMODERATELY RUGGED
CBMECubic Measure62.565 CUBIC INCHES
CQYJMounting Facility PatternRECTANGULAR FIRST MOUNTING FACILITY
CQYJMounting Facility PatternRECTANGULAR SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity4 THREADED HOLE SECOND MOUNTING FACILITY
AXHRMounting Facility Type And Quantity6 UNTHREADED HOLE FIRST MOUNTING FACILITY
CQJXNominal Thread Size0.164 INCHES SECOND MOUNTING FACILITY
CRNGNonpile-Up Main Contact Arrangement2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSKPNonpile-Up Auxiliary Contact Arrangement1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CSXFOperating Voltage Rating And Type At Specified Temp125.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CTDLMain Contact Load Current Rating At Maximum Rated Voltage10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD
CWABMain Contact Maximum Voltage Rating In Volts240.0 AC AND 30.0 DC
AKSLPurpose For Which DesignedGENERAL
ABKWOverall Height6.230 INCHES MAXIMUM
ABHPOverall Length3.250 INCHES MAXIMUM
ABMKOverall Width3.090 INCHES MAXIMUM
CRXHTime Delay1.50 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 15.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME
AEBVUnthreaded Mounting Hole Diameter0.199 INCHES NOMINAL FIRST MOUNTING FACILITY
AKDXWinding Quantity1
BBRGStorage TypeGENERAL PURPOSE WAREHOUSE
TTQYTerminal Type And Quantity11 SCREW ALL FUNCTIONS
AAJDThread Class2B SECOND MOUNTING FACILITY
AAJFThread DirectionRIGHT-HAND SECOND MOUNTING FACILITY
THSDThread Series DesignatorUNC SECOND MOUNTING FACILITY
CMLPThread Quantity Per Inch32 SECOND MOUNTING FACILITY


Back to Top
Back to Top