| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| M83726/28-1501S | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 013342496 | A03300 | 32512 | X | 1 | A | N | A | 0 | 17 Feb 1991 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YE01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | 2 | 3 | ZZ | M83726/28-1501S | 81349 | | ||||||
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
USA
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 6 | 17 Feb 1991 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TD |
Aerospace Integration Corp, 5555 John Givens Rd. Crestview, FL 32539û7019
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| APNP | Duty Type | CONTINUOUS |
| CSQJ | Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APCN | Coil Quantity | 1 |
| ADZC | Environmental Protection | HERMETIC |
| CBBL | Features Provided | POLARIZED |
| CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
| AXHR | Mounting Facility Type And Quantity | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| ABTD | Mounting Slot Width | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CRPQ | Nominal Operating Current Rating And Type | 150.0 MILLIAMPERES DC SINGLE WINDING |
| CRNG | Nonpile-Up Main Contact Arrangement | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 200.0 AC AND 28.0 DC |
| ABKW | Overall Height | 1.310 INCHES MAXIMUM |
| ABHP | Overall Length | 1.718 INCHES MAXIMUM |
| ABMK | Overall Width | 1.025 INCHES MAXIMUM |
| CRXH | Time Delay | 1.50 SECONDS MAXIMUM FIXED OPERATE TIME |
| AKDX | Winding Quantity | 1 |
| ZZZK | Specification/Standard Data | 81349-MIL-R-83726/28 GOVERNMENT SPECIFICATION |
| TTQY | Terminal Type And Quantity | 8 WIRE HOOK ALL FUNCTIONS |
| TEST | Test Data Document | 81349-MIL-R-83726 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |