| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 0661630005 | 3 - Design Control Reference | 2 - Production Item | RIIMIC, LLC | 12338 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 014775531 | A03300 | 32512 | X | 4 | 6 | A | N | A | C | 0 | 11 Aug 2000 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item contains combination of two or more precious metals (silver, gold, platinum).
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZW01 | 1 Jan 2002 | |||||||||||||||||||||||||||||
| YB01 | 1 Dec 2002 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 4 | 9Z | D | 0661630005 | 12338 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 11 Aug 2000 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZT |
Norway
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| APNP | Duty Type | CONTINUOUS |
| ADZC | Environmental Protection | HERMETIC |
| AJSS | Frequency In Hertz | 60.0 MINIMUM AND 400.0 MAXIMUM |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 0.5 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 115.0 AC AND 30.0 DC |
| PMLC | Precious Material And Location | CONTACTS GOLD AND CONTACTS SILVER |
| FEAT | Special Features | HERMETICALLY SEALED; TOTAL SUBMERSIBILITY; INSULATION RESISTANCE 1000.0 MEGOHMS MIN. AT 500 VDC; BREAKDOWN VOLTAGE 500.0 VOLTS RMS 60.0 HERTZ BETWEEN ALL MUTUALLY INSULATED POINTS; TEMP. RANGE MINUS 55.0 TO PLUS 71.0 DEG. C; RATED LIFE 100000 OPERATIONS MIN. AT MAX. RATED LOAD; TERMINALS 0.030 IN. DIA. LOCATED ON 0.200 IN. GRID PATTERN; CONFIGURATION 2 FORM C, DOUBLE POLE DOUBLE THROW; CONTACT RESISTANCE 50.0 MILLIOHMS MAX. INITIAL MEASURED AT MAX. RATED LOAD; SENSITIVITY OF 350.0 MILLIWATTS NOMINAL AT PLUS 25.0 DEG. C; NOMINAL POWER 660.0 MILLIWATTS AT PLUS 25.0 DEG. C; 24 VOLT COIL; WEIGHT IS 0.035 OUNCES |
| CRXH | Time Delay | 0.0003 SECONDS MAXIMUM FIXED RELEASE TIME |
| CRXH | Time Delay | 0.0004 SECONDS MAXIMUM FIXED OPERATE TIME |