| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| M83536/15-013M | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | |
| MIL-PRF-83536/15 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
| 57912800-01 | E - Replace Reference Number | 8 - Replacement NSN | GENERAL DYNAMICS INFORMATION SYSTEMS | 27963 | |
| 021-001061 | E - Replace Reference Number | 8 - Replacement NSN | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26916 | |
| E410-1311 | E - Replace Reference Number | 8 - Replacement NSN | DRI RELAYS INC. | 99699 | |
| BR230-78B2-12V | E - Replace Reference Number | 8 - Replacement NSN | MICROSEMI CORP.-POWER MANAGEMENT | 56623 | |
| BR30-72B2-12V | E - Replace Reference Number | 8 - Replacement NSN | MICROSEMI CORP.-POWER MANAGEMENT | 56623 | |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5945 | 014821975 | A03300 | 32512 | Y | 1 | A | N | A | A | 0 | 13 Feb 2001 |
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FXGX | FXTX | 1 | T | Z | SX | TG | 1 Nov 2005 | |||||||||||||||||||||||
| MC49 | MC13 | 1 | T | Z | PA | 1 Nov 2005 | ||||||||||||||||||||||||
| N9BN | 1 | T | Z | GH | GG | 1 Dec 2013 | ||||||||||||||||||||||||
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Warner-Robins Air Logistics Center, Robins AFB, GA 31098-5609
Naval Inventory Control Point, Philadelphia, PA 19111û5098
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | 2 | E | ZZ | M83536/15-013M | 81349 | | ||||||
| 4 | 1 | E | ZZ | MIL-PRF-83536/15 | 81349 | | ||||||
| E | 8 | 5 | TX | E410-1311 | 99699 | | ||||||
| E | 8 | A | TX | 021-001061 | 26916 | | ||||||
| E | 8 | A | TX | 57912800-01 | 27963 | | ||||||
| E | 8 | E | ZZ | BR230-78B2-12V | 56623 | | ||||||
| E | 8 | E | TX | BR30-72B2-12V | 56623 | | ||||||
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 1 | TX | 0 | 3 | TX | 1 | 25 Jul 2004 | 5945011894086 | 22 Feb 2001 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | P | 72D | Z | 9 | A | H | Z | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 41 | 1 | AAA | 0.2 lbs | 0.037 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | 00 | NA | X | D3 | DO | ZZ | Q | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| APNP | Duty Type | CONTINUOUS |
| APNQ | Arc Quenching Method | AIR |
| ADTV | Case Material | METAL |
| CSQJ | Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APCN | Coil Quantity | 1 |
| CRTL | Criticality Code Justification | FEAT |
| CQYJ | Mounting Facility Pattern | TRIANGLE SINGLE MOUNTING FACILITY |
| AXHR | Mounting Facility Type And Quantity | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| ABTD | Mounting Slot Width | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CRNG | Nonpile-Up Main Contact Arrangement | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSXF | Operating Voltage Rating And Type At Specified Temp | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 10.0 AMPERES DC RESISTIVE LOAD AND 10.0 AMPERES AC RESISTIVE LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 2.0 AMPERES DC LAMP LOAD AND 2.0 AMPERES AC LAMP LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 4.0 AMPERES DC MOTOR LOAD AND 4.0 AMPERES AC MOTOR LOAD |
| CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 8.0 AMPERES DC INDUCTIVE LOAD AND 8.0 AMPERES AC INDUCTIVE LOAD |
| CWAB | Main Contact Maximum Voltage Rating In Volts | 200.0 AC AND 28.0 DC |
| ABKW | Overall Height | 1.010 INCHES MAXIMUM |
| ABHP | Overall Length | 1.718 INCHES MAXIMUM |
| ABMK | Overall Width | 1.025 INCHES MAXIMUM |
| FEAT | Special Features | FAILURE RATE LEVEL 0.1 PERCENT |
| APNA | Winding Dc Resistance Rating | 70.0 OHMS MINIMUM SINGLE WINDING |
| AKDX | Winding Quantity | 1 |
| ZZZK | Specification/Standard Data | 81349-MIL-PRF-83536/15/013M GOVERNMENT SPECIFICATION |
| TTQY | Terminal Type And Quantity | 14 WIRE HOOK ALL FUNCTIONS |
| TEST | Test Data Document | 81349-MIL-PRF-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |