5950-00-027-8211

TRANSFORMER,POWER


5950-00-027-8211 (5950000278211, 000278211)
Part Numbers (3 listings): 240-001-918 | GEA107 | FL6355 |
Summary

FSG 59 / FSC 5950

DEMIL: B

DEMIL INT: 3

HMIC: P

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-027-8211 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
240-001-9183 - Design Control Reference2 - Production ItemU S DEPT OF TRANSPORTATION  08125    CAGE 08125  
GEA1075 - Replaced / Discontinued2 - Production ItemGOODRICH LIGHTING SYSTEMS, INC.  55438      
240-001-9185 - Replaced / Discontinued9 - No Longer UsedSHERJOR INC  75138      
FL6355C - Advisory Reference1 - Incomplete Part NumberCROUSE-HINDS CO  15235    CAGE 15235  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-027-8211 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950000278211A058B032496N1BPU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

000278211

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-027-8211

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-027-8211 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
B4811H1 Nov 2000
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.


FLIS - SEG C - REFERENCE NUMBER | NSN 5950-00-027-8211 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ240-001-918  08125   CAGE/08125
52548GEA107  55438  
359548B240-001-918  75138  
C1948AHFL6355  15235   CAGE/15235
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-027-8211 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX017 Jul 1967
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Jul 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-027-8211 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-00-027-8211 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
GEG69GU1EA0
Code Definitions

G69

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Department of Transportation, Federal Aviation Administration, ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082, Oklahoma City, OK 73125-0082

G

Acquisition Advice Code (AAC_2507)


GENERAL SERVICES ADMINISTRATION (GSA)/CIVIL AGENCY INTEGRATED MATERIEL MANAGED, STOCKED AND ISSUED Identifies GSA/Civil Agency-managed items available from GSA/Civil Agency supply distribution facilities. Requisitions and fund citations will be submitted in accordance with GSA/Civil Agency/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

GE

Service / Agency Code (MOE_CD_2833)


Federal Aviation Administration


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-027-8211 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height3.750 INCHES NOMINAL
ADAQBody Length7.750 INCHES NOMINAL
ADATBody Width3.875 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length6.750 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.844 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
AGAVEnd Item IdentificationAIR TRAFFIC CONTROL TOWER (MISC ITEMS)
AKPVMounting Facility Quantity4 SINGLE GROUP
AXGYMounting MethodFLANGE SINGLE GROUP AND SLOT SINGLE GROUP
ABTDMounting Slot Width0.281 INCHES NOMINAL SINGLE GROUP
AKNAInclosure TypeFULLY INCLOSED
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
ABKWOverall Height3.562 INCHES NOMINAL
ABHPOverall Length7.812 INCHES NOMINAL
BPLCWinding Function And Quantity1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current6.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
CWJSWinding Operating Voltage120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CWJSWinding Operating Voltage8.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
CRMJWinding Power Rating100.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
TTQYTerminal Type And Quantity2 CONNECTOR, RECEPTACLE AND 2 LINE CORD


Back to Top