Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
10125211 | 3 - Design Control Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5950 | 000435220 | A058B0 | 32496 | X | 1 | A | P | U | 26 Dec 1969 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
YB01 | 1 Sep 2008 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 10125211 | 18876 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 24 Nov 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BD | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | JC | X | EC | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
No requirement
ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 3.360 INCHES MINIMUM AND 3.390 INCHES MAXIMUM |
ADAT | Body Width | 3.922 INCHES MINIMUM AND 3.952 INCHES MAXIMUM |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | Frequency Rating | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
AXGY | Mounting Method | THREADED STUD SINGLE GROUP |
CQJX | Nominal Thread Size | 0.190 INCHES SINGLE GROUP |
AKNA | Inclosure Type | HERMETICALLY SEALED |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AARG | Reliability Indicator | NOT ESTABLISHED |
FEAT | Special Features | 1PRIMARY WINDING; 5,SECONDARY WINDINGS |
ABHP | Overall Length | 5.935 INCHES MINIMUM AND 5.965 INCHES MAXIMUM |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CRBZ | Winding Operating Current | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | Winding Operating Current | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | Winding Operating Voltage | 127.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | Winding Operating Voltage | 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | Winding Operating Voltage | 90.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | Winding Operating Voltage | 90.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
ACZX | Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
TTQY | Terminal Type And Quantity | 14 TURRET |
THSD | Thread Series Designator | UNF SINGLE GROUP |