5950-00-059-5920

COIL,RADIO FREQUENCY


5950-00-059-5920 (5950000595920, 000595920)
Part Numbers (32 listings): SM-C-523309-3 | SM-B-650699-3 | 0681036 | 99048416 | 1025-20 | 331-113-020 | 09-00269-005 | 11253178-11 | 10-101 | 696017-100 | 5L5053-003-11 | 134761-0013 | 212035008 | 212091000 | 368474-14 | 4585367 | LD4585367 | LD0672863 | 494507 | P3H011611-03 | 161291-011 | 419451-11 | 538291-13 | 9140-0158 | SM-A-595835-109 | 711572 | 2029742-0715 | 1A1002M | 4426-6K | 09-4426-6K | 40-001032-13 | 0246-9-2033-2 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1961

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.003 cu ft

Replacement NSN:

5950-01-193-0262

Replacement Date: 22 May 1998

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-059-5920 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SM-C-523309-33 - Design Control Reference2 - Production ItemUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
SM-B-650699-35 - Replaced / Discontinued2 - Production ItemUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
06810365 - Replaced / Discontinued2 - Production ItemSAFRAN  F6151    CAGE F6151  
990484165 - Replaced / Discontinued2 - Production ItemTHALES  F6481    CAGE F6481  
990484165 - Replaced / Discontinued2 - Production ItemTHALES DEFENCE & SECURITY  D2416    CAGE D2416  
1025-205 - Replaced / Discontinued2 - Production ItemBECKER FLUGFUNKWERK GMBH  D2356    CAGE D2356  
331-113-0205 - Replaced / Discontinued2 - Production ItemINTERSTATE ELECTRONICS CORPORATION  07421    CAGE 07421  
09-00269-0055 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  00724    CAGE 00724  
1025-205 - Replaced / Discontinued2 - Production ItemDELAVAN INC  71895    CAGE 71895  
11253178-115 - Replaced / Discontinued2 - Production ItemBALLISTIC MISSILE DEFENSE SYSTEMS  17773    CAGE 17773  
10-1015 - Replaced / Discontinued2 - Production ItemGOWANDA ELECTRONICS CORP.  24226    CAGE 24226  
696017-1005 - Replaced / Discontinued2 - Production ItemBAE SYSTEMS NATIONAL SECURITY  12436    CAGE 12436  
5L5053-003-115 - Replaced / Discontinued2 - Production ItemEADS DEUTSCHLAND GMBH  D1901    CAGE D1901  
134761-00135 - Replaced / Discontinued2 - Production ItemTHALES DEFENSE & SECURITY, INC.  65597    CAGE 65597  
2120350085 - Replaced / Discontinued2 - Production ItemZODIAC DATA SYSTEMS  F7078    CAGE F7078  
2120910005 - Replaced / Discontinued2 - Production ItemZODIAC DATA SYSTEMS  F7078    CAGE F7078  
368474-145 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  37695    CAGE 37695  
1025-205 - Replaced / Discontinued2 - Production ItemAMERICAN PRECISION INDUSTRIES INC  99800    CAGE 99800  
45853675 - Replaced / Discontinued2 - Production ItemROHDE & SCHWARZ GMBH & CO. KG  D0894    CAGE D0894  
LD45853675 - Replaced / Discontinued2 - Production ItemROHDE & SCHWARZ GMBH & CO. KG  D0894    CAGE D0894  
LD06728635 - Replaced / Discontinued2 - Production ItemROHDE & SCHWARZ GMBH & CO. KG  D0894    CAGE D0894  
4945075 - Replaced / Discontinued2 - Production ItemTHALES COMMUNICATIONS &  F0057    CAGE F0057  
P3H011611-035 - Replaced / Discontinued2 - Production ItemRADIO FREQUENCY SYSTEMS FRANCE  F4081    CAGE F4081  
161291-0115 - Replaced / Discontinued2 - Production ItemBAE SYSTEMS INFORMATION AND  81413    CAGE 81413  
419451-115 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
538291-135 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
9140-01585 - Replaced / Discontinued2 - Production ItemAGILENT TECHNOLOGIES, INC.  1MY97    CAGE 1MY97  
SM-A-595835-1095 - Replaced / Discontinued2 - Production ItemUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
7115725 - Replaced / Discontinued9 - No Longer UsedAIL SYSTEMS INC  04660    CAGE 04660  
1025-205 - Replaced / Discontinued9 - No Longer UsedAMPHENOL-TUCHEL ELECTRONICS GMBH  D8311    CAGE D8311  
P3H011611-035 - Replaced / Discontinued9 - No Longer UsedALCATEL CIT DEPARTEMENT  F6116    CAGE F6116  
2029742-07155 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  06845    CAGE 06845  
9140-01585 - Replaced / Discontinued9 - No Longer UsedHEWLETT PACKARD CO  28480    CAGE 28480  
1A1002M5 - Replaced / Discontinued9 - No Longer UsedWEST CAP ARIZONA  32159    CAGE 32159  
4426-6K5 - Replaced / Discontinued9 - No Longer UsedJEFFERS ELECTRONICS INC  59474    CAGE 59474  
09-4426-6K5 - Replaced / Discontinued9 - No Longer UsedJEFFERS ELECTRONICS INC  59474    CAGE 59474  
40-001032-135 - Replaced / Discontinued9 - No Longer UsedINTERLINK COMMUNICATIONS INC  30890    CAGE 30890  
2029742-07155 - Replaced / Discontinued9 - No Longer UsedFERUM CO INC THE  04384    CAGE 04384  
0246-9-2033-27 - Vendor Item Drawing Reference2 - Production ItemUSACECOM INTELLIGENCE ELECTRONIC  15942    CAGE 15942  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-059-5920 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950000595920A058B006338X1APAU01 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

000595920

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-059-5920

A058B0

Federal Item Identification Guide (FIIG_4065)

06338

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-059-5920 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YJ011 Apr 1991
YW011 Apr 1991
ZA011 Apr 1991
ZB011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZN011 Apr 1991
ZP011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZX011 Apr 1991
ZW011 Dec 1995
YA011 Dec 1999
WB011 Feb 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5950-00-059-5920 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4325TXDSM-C-523309-3  80063   CAGE/80063
3525KED161291-011  81413   CAGE/81413
3525TXD419451-11  96214   CAGE/96214
352648D538291-13  96214   CAGE/96214
452ETXD1025-20  99800   CAGE/99800
4523ZGD4585367  D0894   CAGE/D0894
3521ZGDLD0672863  D0894   CAGE/D0894
15269ZDLD4585367  D0894   CAGE/D0894
3526ZGD5L5053-003-11  D1901   CAGE/D1901
4523ZGA1025-20  D2356   CAGE/D2356
4529ZGD99048416  D2416   CAGE/D2416
4524ZFC0681036  F6151   CAGE/F6151
4524ZFB99048416  F6481   CAGE/F6481
524ZFD212035008  F7078   CAGE/F7078
524ZFD212091000  F7078   CAGE/F7078
4524ZFD494507  F0057   CAGE/F0057
524ZFBP3H011611-03  F4081   CAGE/F4081
3522TAD09-00269-005  00724   CAGE/00724
525ZZ9140-0158  1MY97   CAGE/1MY97
352548D10-101  24226   CAGE/24226
1526TXD331-113-020  07421   CAGE/07421
3525TXD696017-100  12436   CAGE/12436
3525TXD368474-14  37695   CAGE/37695
152548A134761-0013  65597   CAGE/65597
52ETX1025-20  71895   CAGE/71895
15269ZDSM-A-595835-109  80063   CAGE/80063
15269ZDSM-B-650699-3  80063   CAGE/80063
59ETXB09-4426-6K  59474   CAGE/59474
595TXB4426-6K  59474   CAGE/59474
3595TXB9140-0158  28480   CAGE/28480
3595KED40-001032-13  30890   CAGE/30890
3595TXD1A1002M  32159   CAGE/32159
3591TXB2029742-0715  04384   CAGE/04384
3595KEB711572  04660   CAGE/04660
3591TXB2029742-0715  06845   CAGE/06845
4594ZFDP3H011611-03  F6116   CAGE/F6116
4593ZGB1025-20  D8311   CAGE/D8311
4721TXD0246-9-2033-2  15942   CAGE/15942
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

KE

Reference Number Action Activity Code (RNAAC_2900)


Naval ICP, Philadelphia, PA 19111

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZF

Reference Number Action Activity Code (RNAAC_2900)


France

C

Reference Number Status Code (RNSC_2923)


The reference number originates from a descriptive technical document of the product, which may be used as a procurement document without restrictions. The NCAGE specified for this reference number identifies the originating organization or agency of the document but not the supply source of the item. NOTE: This code is to be allocated to reference numbers originating from generally available specifications/standards or to drawing numbers for which the Government has separate property rights or for which the author does not claim any property rights.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-059-5920 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX022 May 1998 5950011930262 22 May 1998
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 May 1998

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5950-01-193-0262

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

22 May 1998

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-059-5920 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-00-059-5920 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5950-00-059-5920 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
P1AAA0.1 lbs0.003 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD3EQU
Code Definitions

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.003 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-059-5920 Submit RFQ
MRCDecoded RequirementClear Text Reply
ACZPCoil Form TypeSOLID SINGLE COMPONENT
ACZRCore ConstructionS0LID SINGLE COMPONENT
CRGSDc Resistance Rating In Ohms1.000 SINGLE COMPONENT SINGLE WINDING
CBBLFeatures ProvidedTINNED WIRE LEADS
AEHZMaximum Operating Temp125.0 DEG CELSIUS
AXGYMounting MethodTERMINAL SINGLE GROUP
ADAVOverall Diameter0.085 INCHES MINIMUM AND 0.105 INCHES MAXIMUM
AKNAInclosure TypeFULLY INCLOSED
ACYVInductance Rating1.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
CRHJQuality Factor25 MINIMUM SINGLE COMPONENT SINGLE WINDING
BKPLRating MethodELECTRICAL SINGLE COMPONENT SINGLE WINDING
AARGReliability IndicatorNOT ESTABLISHED
ABHPOverall Length0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
FEATSpecial FeaturesINDUCTANCE TOLERANCE,10 PCT
CRBZWinding Operating Current425.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
TTQYTerminal Type And Quantity2 WIRE LEAD


Back to Top
Back to Top