5950-00-076-3275

TRANSFORMER,POWER


5950-00-076-3275 (5950000763275, 000763275)
Part Number (1 listing): T15B
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-076-3275 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
T15B3 - Design Control Reference9 - No Longer UsedBROWNING LABORATORIES INC  09129      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-076-3275 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950000763275A058B032496X1APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

000763275

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-076-3275

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-076-3275 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-076-3275 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX017 Jul 1967
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Jul 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-076-3275 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-076-3275 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
ABTDMounting Slot Width0.188 INCHES NOMINAL SINGLE GROUP
AXGYMounting MethodFLANGE SINGLE GROUP
AKNAInclosure TypePARTIALLY INCLOSED, DOUBLE SHELL
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
ABKWOverall Height3.500 INCHES NOMINAL
ABHPOverall Length2.875 INCHES NOMINAL
ABMKOverall Width2.812 INCHES NOMINAL
BPLCWinding Function And Quantity2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current2.1 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CRBZWinding Operating Current2.1 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWinding Operating Current600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
CRBZWinding Operating Current5.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
CWJSWinding Operating Voltage115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY
CWJSWinding Operating Voltage1250.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
CWJSWinding Operating Voltage230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY
CWJSWinding Operating Voltage2.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage2.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage6.30 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
ACZXWinding Shielding MethodEXTERNAL INCLOSURE SINGLE COMPONENT
TTQYTerminal Type And Quantity12 WIRE LEAD


Back to Top
Back to Top