5950-00-172-5341

TRANSFORMER,POWER AUTOTRANSFORMER


5950-00-172-5341 (5950001725341, 001725341)
Part Number (1 listing): 6292
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Sep 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-172-5341 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
62923 - Design Control Reference2 - Production ItemDECCO INC  07183      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-172-5341 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950001725341A058B036166XKAPU1 Sep 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

001725341

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-172-5341

A058B0

Federal Item Identification Guide (FIIG_4065)

36166

Item Naming Code (INC_4080)

1 Sep 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-172-5341 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ011 Apr 1991
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5950-00-172-5341 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332648D6292  07183  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-172-5341 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX011 Sep 1972
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Sep 1972

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-172-5341 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
48P595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

48

Originating Activity Code (ORIG_ACTY_CD_4210)


Federal Aviation Administration, Oklahoma City, OK 73125

P

Less Than Carload (LCL_CD_2760)


77.5

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-172-5341 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height2.688 INCHES NOMINAL
ADAQBody Length3.313 INCHES NOMINAL
ADATBody Width2.750 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
AKPVMounting Facility Quantity4 SINGLE GROUP
ABTBMounting Hole Diameter0.219 INCHES NOMINAL SINGLE GROUP
AXGYMounting MethodFLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
AKNAInclosure TypeOPEN
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
CRBZWinding Operating Current10.7 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
BPLCWinding Function And Quantity1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
CWJSWinding Operating Voltage28.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT OR 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
CRMJWinding Power Rating300.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT
TTQYTerminal Type And Quantity3 THREADED STUD