5950-00-178-8514

TRANSFORMER,AUDIO FREQUENCY


5950-00-178-8514 (5950001788514, 001788514)
Part Numbers (3 listings): 564392 | 558254 | 95G19 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1961

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-178-8514 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
5643923 - Design Control Reference2 - Production ItemSTEWART-WARNER CORPORATION  57733    CAGE 57733  
5582543 - Design Control Reference2 - Production ItemSTEWART-WARNER CORPORATION  57733    CAGE 57733  
95G193 - Design Control Reference2 - Production ItemTARGET CORPORATION  20284    CAGE 20284  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-178-8514 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950001788514A058B000780X1APU1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

001788514

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-178-8514

A058B0

Federal Item Identification Guide (FIIG_4065)

00780

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-178-8514 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZP011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-178-8514 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX013 Jun 1967
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Jun 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-178-8514 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-178-8514 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height2.156 INCHES NOMINAL
ADAQBody Length1.891 INCHES NOMINAL
ADATBody Width1.781 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.313 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating300.0 HERTZ MINIMUM SINGLE COMPONENT AND 4.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
ACZFMaximum Transformer Power Rating3.0 WATTS SINGLE COMPONENT
AKPVMounting Facility Quantity4 SINGLE GROUP
AXGYMounting MethodTHREADED STUD SINGLE GROUP
CQJXNominal Thread Size0.138 INCHES SINGLE GROUP
ACYWImpedance Rating In Ohms500.0 NOMINAL SINGLE COMPONENT ALL SECONDARY
ACYWImpedance Rating In Ohms5000.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY
AKNAInclosure TypeFULLY INCLOSED
ACZHPrimary To Secondary Turn Ratio3.3 TO 1 SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
CRBZWinding Operating Current10.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL SECONDARY
BPLCWinding Function And Quantity1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
ACZXWinding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TTQYTerminal Type And Quantity6 SOLDER STUD
CMLPThread Quantity Per Inch32 SINGLE GROUP
THSDThread Series DesignatorUNC SINGLE GROUP


Back to Top
Back to Top