| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 243154P2 | 3 - Design Control Reference | 2 - Production Item | BAE SYSTEMS INFORMATION AND | 94117 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5950 | 004503435 | A058B0 | 32496 | X | 1 | A | P | U | 19 Feb 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N9BN | N9ND | 0 | 0 | Z | KE | KE | 1 Jun 2006 | |||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 3 | 2 | A | TX | D | 243154P2 | 94117 | | ||||
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 24 Feb 1972 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KE | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
Naval ICP, Philadelphia, PA 19111
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAU | Body Height | 1.160 INCHES MAXIMUM |
| ADAQ | Body Length | 2.820 INCHES MAXIMUM |
| ADAT | Body Width | 2.250 INCHES MAXIMUM |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| AEHZ | Maximum Operating Temp | 155.0 DEG CELSIUS |
| AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
| ABTB | Mounting Hole Diameter | 0.165 INCHES MINIMUM SINGLE GROUP AND 0.175 INCHES MAXIMUM SINGLE GROUP |
| AXGY | Mounting Method | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| AKNA | Inclosure Type | FULLY INCLOSED |
| ACZC | Input-Output Phase Relationship | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| ACZD | Transformer Winding Connection Type | DELTA-WYE |
| CRBZ | Winding Operating Current | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
| CRBZ | Winding Operating Current | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | Winding Operating Current | 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | Winding Operating Current | 15.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CWJS | Winding Operating Voltage | 113.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 195.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | Winding Operating Voltage | 1067.00 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 1133.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CWJS | Winding Operating Voltage | 1891.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 1008.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CWJS | Winding Operating Voltage | 87.30 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CWJS | Winding Operating Voltage | 87.30 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| ACZX | Winding Shielding Method | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TTQY | Terminal Type And Quantity | 14 TURRET |