5950-00-488-9901

TRANSFORMER,POWER


5950-00-488-9901 (5950004889901, 004889901)
Part Number (1 listing): 2921
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 18 May 1970

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-488-9901 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
29213 - Design Control Reference2 - Production ItemGENERAL MICROWAVE CORPORATION  11332      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-488-9901 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950004889901A058B032496X1APU18 May 1970
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

004889901

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-488-9901

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

18 May 1970

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-488-9901 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
N9BN3DZGHKE1 Jun 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

D

Acquisition Method Suffix Code (AMSC_2876)


The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5950-00-488-9901 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332ATXD2921  11332  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-488-9901 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-00-488-9901 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSYU1EA0
DSSMSYU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-488-9901 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height4.250 INCHES NOMINAL4.250 INCHES NOMINAL
ADAQBody Length5.620 INCHES NOMINAL5.620 INCHES NOMINAL
ADATBody Width3.500 INCHES NOMINAL3.500 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.930 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.930 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
AKPVMounting Facility Quantity4 SINGLE GROUP4 SINGLE GROUP
AXGYMounting MethodSLOT SINGLE GROUPSLOT SINGLE GROUP
ABTDMounting Slot Width0.234 INCHES NOMINAL SINGLE GROUP0.234 INCHES NOMINAL SINGLE GROUP
AKNAInclosure TypeFULLY INCLOSEDFULLY INCLOSED
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHEDNOT ESTABLISHED
FEATSpecial Features2PRIMARY WINDINGS; FIVE SECONDARY WINDINGS,ALSO CURRENT AND VOLTAGE ON SECONDARIES HAVE BEEN RECTIFIED
CRBZWinding Operating Current1.8 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
BPLCWinding Function And Quantity2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current325.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWinding Operating Current340.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
CRBZWinding Operating Current375.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage17.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage15.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY22.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage22.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage300.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY17.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TTQYTerminal Type And Quantity17 WIRE LEAD


Back to Top
Back to Top