| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| R-7A | 3 - Design Control Reference | 9 - No Longer Used | MAGNETEK INC | 04386 | |
| 1C1804-118 | 5 - Replaced / Discontinued | 2 - Production Item | GENERAL ELECTRIC COMPANY | 07482 | |
| 1C1804-118 | 5 - Replaced / Discontinued | 9 - No Longer Used | GENERAL ELECTRIC CO | 24446 | |
| 1C11804-118 | 5 - Replaced / Discontinued | 9 - No Longer Used | GENERAL ELECTRIC CO | 24446 | |
| R-7A | C - Advisory Reference | 1 - Incomplete Part Number | MAGNETEK INC | 0LG51 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5950 | 005520891 | A058B0 | 32496 | X | 1 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 9 | E | TX | R-7A | 04386 | | ||||||
| 3 | 5 | 2 | 5 | TX | D | 1C1804-118 | 07482 | | ||||
| 3 | 5 | 9 | 5 | TX | B | 1C11804-118 | 24446 | | ||||
| 3 | 5 | 9 | 5 | TX | B | 1C1804-118 | 24446 | | ||||
| C | 1 | E | ZZ | 9F | R-7A | 0LG51 | | |||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
USA
CAGE Status Change
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 7 Jan 1979 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
77.5
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAU | Body Height | 3.187 INCHES NOMINAL3.187 INCHES NOMINAL |
| ADAQ | Body Length | 2.750 INCHES NOMINAL2.750 INCHES NOMINAL |
| ADAT | Body Width | 2.625 INCHES NOMINAL2.625 INCHES NOMINAL |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
| AKPV | Mounting Facility Quantity | 4 SINGLE GROUP4 SINGLE GROUP |
| ABTD | Mounting Slot Width | 0.188 INCHES NOMINAL SINGLE GROUP0.188 INCHES NOMINAL SINGLE GROUP |
| AXGY | Mounting Method | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUP |
| AKNA | Inclosure Type | PARTIALLY INCLOSED, DOUBLE SHELLPARTIALLY INCLOSED, DOUBLE SHELL |
| ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AARG | Reliability Indicator | NOT ESTABLISHEDNOT ESTABLISHED |
| BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
| CRBZ | Winding Operating Current | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | Winding Operating Current | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | Winding Operating Current | 50.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CWJS | Winding Operating Voltage | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY600.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | Winding Operating Voltage | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | Winding Operating Voltage | 600.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | Winding Power Rating | 30.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| ACZX | Winding Shielding Method | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| CRMJ | Winding Power Rating | 10.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY12.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | Winding Power Rating | 12.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| TTQY | Terminal Type And Quantity | 10 WIRE LEAD |