| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| C8049 | 3 - Design Control Reference | 9 - No Longer Used | AMPEX SYSTEMS CORP | 92739 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5950 | 005812119 | A058B0 | 00780 | X | 4 | 9 | A | P | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB | ||||||||||||||||||||||||||||||
| ZW | ||||||||||||||||||||||||||||||
| ZZ | ||||||||||||||||||||||||||||||
| YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
| N9BN | 0 | 0 | Z | GH | HD | 1 Jun 2006 | ||||||||||||||||||||||||
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ADAU | Body Height | 2.375 INCHES NOMINAL |
| ADAQ | Body Length | 1.625 INCHES NOMINAL |
| ADAT | Body Width | 1.625 INCHES NOMINAL |
| ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | Frequency Rating | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 15.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
| AXGY | Mounting Method | THREADED STUD SINGLE GROUP |
| ACYW | Impedance Rating In Ohms | 120000.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| ACYW | Impedance Rating In Ohms | 30.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| AKNA | Inclosure Type | FULLY INCLOSED |
| ACZH | Primary To Secondary Turn Ratio | 1 TO 2 SINGLE COMPONENT |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| ACYE | Transformer Function | INPUT |
| BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| ACZX | Winding Shielding Method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TTQY | Terminal Type And Quantity | 6 TAB, SOLDER LUG |