5950-00-646-2496

TRANSFORMER,POWER


5950-00-646-2496 (5950006462496, 006462496)
Part Number (1 listing): CVE150157-2
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1961

Unit Weight: None

Unit Size:

Unit Pack Cube: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-646-2496 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CVE150157-23 - Design Control Reference2 - Production ItemTRIUMPH AEROSTRUCTURES, LLC  80378    CAGE 80378  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-646-2496 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950006462496A058B032496XKAPU1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

006462496

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-646-2496

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-646-2496 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G94000B1 Oct 1993
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

B

Acquisition Advice Code (AAC_2507)


INVENTORY CONTROL POINT (ICP)-REGULATED (Service/Agency use only.) Issue, transfer, or shipment is controlled by the ICP. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedure.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-646-2496 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
5TX024 Nov 1970
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Nov 1970

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-646-2496 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-00-646-2496 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DSSMSYU1EA0
DNSMSVU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5950-00-646-2496 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
AP101AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000JCXD1D1QQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

JC

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D1

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566 or PPP-B-676, folding or setup box.

D1

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566 or PPP-B-676, folding or setup box.

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-646-2496 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height1.750 INCHES NOMINAL
ADAQBody Length1.310 INCHES NOMINAL
ADATBody Width1.310 INCHES NOMINAL
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
AKPVMounting Facility Quantity4 SINGLE GROUP
AXGYMounting MethodFLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
AKNAInclosure TypeOPEN
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
BPLCWinding Function And Quantity1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current180.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
CWJSWinding Operating Voltage115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CWJSWinding Operating Voltage25.20 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
ACZXWinding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TTQYTerminal Type And Quantity4 TAB, SOLDER LUG


Back to Top
Back to Top