Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
4302 | 3 - Design Control Reference | 9 - No Longer Used | BELL INDUSTRIES INC | 76493 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5950 | 009281321 | A058B0 | 06338 | X | 1 | A | P | U | 29 Aug 1966 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YD01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | E | TX | D | 4302 | 76493 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 7 Apr 1967 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ACZU | Adjustment Device Drive Type | SHAFT SINGLE COMPONENT |
CTHD | Adjustment Method And Quantity | 1 ADJUSTABLE CORE SINGLE COMPONENT |
ADAQ | Body Length | 0.625 INCHES NOMINAL |
ACZP | Coil Form Type | HOLLOW SINGLE COMPONENT |
ACZR | Core Construction | POWDERED SINGLE COMPONENT |
CRGS | Dc Resistance Rating In Ohms | 0.017 SINGLE COMPONENT SINGLE WINDING |
AXGY | Mounting Method | THREADED BUSHING SINGLE GROUP |
CQJX | Nominal Thread Size | 0.164 INCHES SINGLE GROUP |
AKNA | Inclosure Type | OPEN |
ACYV | Inductance Rating | 0.30 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE WINDING AND 0.39 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CRHJ | Quality Factor | 44 MINIMUM SINGLE COMPONENT SINGLE WINDING AND 57 MAXIMUM SINGLE COMPONENT SINGLE WINDING |
BKPL | Rating Method | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
AARG | Reliability Indicator | NOT ESTABLISHED |
ADAV | Overall Diameter | 0.312 INCHES NOMINAL |
ABHY | Turn Quantity | 7-1/4 SINGLE COMPONENT SINGLE WINDING |
CRBZ | Winding Operating Current | 1.6 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG |
THSD | Thread Series Designator | UNC SINGLE GROUP |