5950-00-946-3305

TRANSFORMER,POWER


5950-00-946-3305 (5950009463305, 009463305)
Part Numbers (8 listings): 8421500 | BX-9383 | 926C417P1 | PEI6609 | K4946 | ST28978 | 9T33Y5427 | 926C417 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 9 Mar 1966

Unit Weight: 2.1 lbs

Unit Size: 2.9in x 2.3in x 2.3in

Unit Pack Cube: 0.008 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-946-3305 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
84215003 - Design Control Reference2 - Production ItemAIR FORCE LOGISTICS COMMAND  97151      
BX-93835 - Replaced / Discontinued2 - Production ItemBALTIMORE TRANSFORMER COMPANY  85323      
926C417P15 - Replaced / Discontinued2 - Production ItemBAE SYSTEMS CONTROLS INC.  89954    CAGE 89954  
PEI66095 - Replaced / Discontinued2 - Production ItemPRECISION ELECTRONICS, INC.  13483    CAGE 13483  
K49465 - Replaced / Discontinued2 - Production ItemKEYTRONICS, INC.  51181      
ST 289785 - Replaced / Discontinued9 - No Longer UsedSTERLING TRANSFORMER CORP  97102      
9T33Y54275 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  03512      
926C4175 - Replaced / Discontinued9 - No Longer UsedBAE SYSTEMS CONTROLS INC.  89954    CAGE 89954  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-946-3305 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950009463305A058B032496X1APU9 Mar 1966
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

009463305

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-946-3305

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

9 Mar 1966

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-946-3305 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZW011 Nov 2005
FXGXFXTX1GZSX1 Jun 2006
ZU011 Apr 2008
YD011 Sep 2016
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043


FLIS - SEG C - REFERENCE NUMBER | NSN 5950-00-946-3305 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ATX8421500  97151  
3524TAD926C417P1  89954   CAGE/89954
524ZZPEI6609  13483   CAGE/13483
4526TXDK4946  51181  
525TXBX-9383  85323  
359ETXB926C417  89954   CAGE/89954
595TXBST 28978  97102  
3595TXB9T33Y5427  03512  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

TA

Reference Number Action Activity Code (RNAAC_2900)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-946-3305 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX024 Nov 1968
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Nov 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-946-3305 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SG595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

SG

Originating Activity Code (ORIG_ACTY_CD_4210)


403 SCMS/GUED, 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-00-946-3305 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NEA0
DSSMSJU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5950-00-946-3305 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA2.1 lbs2.9in x 2.3in x 2.3in0.008 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00GB000D3EC00QQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

2.1 lbs

Unit Pack Weight (UP_WT_5153)

2.9in x 2.3in x 2.3in

Unit Pack Size (UP_SZ_5154)

0.008 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

GB

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-PRF-121, greaseproof, waterproof barrier

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

EC

Intermediate Container Code (INTMD_CTNR_CD_5167)


ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-946-3305 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height2.300 INCHES MAXIMUM
ADAQBody Length2.860 INCHES MAXIMUM
ADATBody Width2.250 INCHES MAXIMUM
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length2.190 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.510 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating400.0 HERTZ NOMINAL SINGLE COMPONENT
AEHZMaximum Operating Temp170.0 DEG CELSIUS
AKPVMounting Facility Quantity4 SINGLE GROUP
AXGYMounting MethodTHREADED HOLE SINGLE GROUP
CQJXNominal Thread Size0.138 INCHES SINGLE GROUP
AKNAInclosure TypeFULLY INCLOSED
ACZCInput-Output Phase RelationshipTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
FEATSpecial FeaturesONE PRIMARY WINDING; FIVE SECONDARY WINDINGS WITH FIRST,SECOND,FOURTH,AND FIFTH WINDINGS CENTER TAPPED
ACZDTransformer Winding Connection TypeWYE-OPEN DELTA
CRBZWinding Operating Current11.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
BPLCWinding Function And Quantity1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current1.02 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CRBZWinding Operating Current25.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 825.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
CRBZWinding Operating Current3.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CRBZWinding Operating Current38.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 133.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage16.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 19.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 54.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 70.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWinding Operating Voltage20.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 94.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 114.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage3.47 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWinding Operating Voltage58.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
CRMJWinding Power Rating9.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWinding Power Rating0.638 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
CRMJWinding Power Rating22.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJWinding Power Rating26.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
TTQYTerminal Type And Quantity23 TAB, SOLDER LUG
THSDThread Series DesignatorUNC SINGLE GROUP


Back to Top