5950-00-973-9976

TRANSFORMER,AUDIO FREQUENCY


5950-00-973-9976 (5950009739976, 009739976)
Part Number (1 listing): TA11
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1960

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-00-973-9976 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TA113 - Design Control Reference9 - No Longer UsedEMERSON ELECTRIC CO  80089    CAGE 80089  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5950-00-973-9976 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950009739976A058B000780X1APU1 Jan 1960
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

009739976

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-00-973-9976

A058B0

Federal Item Identification Guide (FIIG_4065)

00780

Item Naming Code (INC_4080)

1 Jan 1960

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5950-00-973-9976 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G86000C1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-00-973-9976 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX013 Jun 1967
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Jun 1967

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-00-973-9976 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-00-973-9976 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height2.000 INCHES NOMINAL
ADAQBody Length2.438 INCHES NOMINAL
ADATBody Width1.750 INCHES NOMINAL
AEJNDistance Between Mounting Facility Centers2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating30.0 HERTZ MINIMUM SINGLE COMPONENT AND 20.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
ACZFMaximum Transformer Power Rating5.0 WATTS SINGLE COMPONENT
AKPVMounting Facility Quantity2 ALL GROUPINGS
AXGYMounting MethodFLANGE ALL GROUPINGS
ACYWImpedance Rating In Ohms16.0 NOMINAL SINGLE COMPONENT 1ST SECONDARY
ACYWImpedance Rating In Ohms48.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY
ACYWImpedance Rating In Ohms8.0 NOMINAL SINGLE COMPONENT 2ND SECONDARY
AKNAInclosure TypeOPEN
FEATSpecial FeaturesPLATE COUPLING
BPLCWinding Function And Quantity1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current275.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
ACZXWinding Shielding MethodINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TTQYTerminal Type And Quantity6 WIRE LEAD


Back to Top
Back to Top