Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
GA1587E | 3 - Design Control Reference | 2 - Production Item | COMMUNICATIONS & POWER INDUSTRIES | 99313 | ![]() |
821505-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 96214 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5950 | 010092673 | A058B0 | 32494 | N | 4 | 9 | A | P | A | 7 Sep 1975 |
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH | ||||||||||||||||||||||||||||||
ZT | ||||||||||||||||||||||||||||||
ZZ | ||||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
B482 | 3 | C | T | 88 | 1 Mar 1999 | |||||||||||||||||||||||||
NFSC | 3 | C | 5 | E | FA | GG | 1 Mar 1999 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
A Federal Aviation Administration activity is providing depot maintenance support.
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
For agencies excluded from the DSOR program. Not for DoD Service's use.
Federal Aviation Agency, Mike Monroney Aeronautical Center, Oklahoma City, OK
Naval Inventory Control Point, Philadelphia, PA 19111û5098
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 723 | Z | 9 | A | H | Z | P | 063498 | X | 34420 | VOICE-COIL-DYNAMIC-LOUDSPEAKER |
Federal Aviation Administration, Oklahoma City, OK 73125
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Oklahoma City Air Logistics Center, 3001 Staff Drive, Tinker AFB, OK 73145-3303
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Department of Transportation, Federal Aviation Administration, ATTN: COE AML-030 TSF BLDG 215 PO BOX 25082, Oklahoma City, OK 73125-0082
Department of the Air Force
Department of the Navy
Federal Aviation Administration
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | ASR-8 |
ADAQ | Body Length | 16.610 INCHES MINIMUM AND 16.670 INCHES MAXIMUM |
ADAR | Body Outside Diameter | 15.940 INCHES MINIMUM AND 16.120 INCHES MAXIMUM |
CRGS | Dc Resistance Rating In Ohms | 4.000 SINGLE COMPONENT SINGLE WINDING |
AEJN | Distance Between Mounting Facility Centers | 17.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | Mounting Facility Quantity | 8 1ST GROUP |
ABTB | Mounting Hole Diameter | 0.328 INCHES NOMINAL SINGLE GROUP |
AXGY | Mounting Method | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
AKNA | Inclosure Type | OPEN |
AARG | Reliability Indicator | NOT ESTABLISHED |
ADAV | Overall Diameter | 17.970 INCHES MINIMUM AND 18.030 INCHES MAXIMUM |
ABHP | Overall Length | 19.580 INCHES MINIMUM AND 20.180 INCHES MAXIMUM |
FEAT | Special Features | FORCED AIR COOLED WITH 125 CFM AIR FLOW MAX. REQUIRED; FUNCTION, FOCUS COIL, SOLENOID; REFERENCE DATA, TI-6310.13A, FA 9335, 1A5A1L1, PG 10-59, VOL 2, SEC 1-11 |
CRBZ | Winding Operating Current | 25.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CWJS | Winding Operating Voltage | 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE WINDING |
AKDX | Winding Quantity | 1 SINGLE COMPONENT |
TTQY | Terminal Type And Quantity | 2 TERMINAL BLOCK W/SCREWS |