Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
ECO125589 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 06845 | ![]() |
0N205422 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NATIONAL SECURITY AGENCY | 98230 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5950 | 010564705 | A058B0 | 00777 | X | 1 | A | P | U | 23 Feb 1978 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC | ||||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 2 | SJ | ECO125589 | 06845 | ![]() | ||||||
4 | 7 | 2 | A | TX | A | 0N205422 | 98230 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
Air Force Cryptological Support Center, San Antonio, TX 78243-5000
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SJ | 595 | Z | 9 | A | H | Z | W | 063420 | Z | 35355 | TRANSFORMERS-NOI-OR-TRANSFORMER-PAR |
Air Force Cryptological Support Center, San Antonio, TX 78243-5000
Transformer, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.750 INCHES NOMINAL |
ADAQ | Body Length | 0.562 INCHES NOMINAL |
ADAT | Body Width | 0.562 INCHES NOMINAL |
ACZP | Coil Form Type | SOLID SINGLE COMPONENT |
AEJN | Distance Between Mounting Facility Centers | 0.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CBBL | Features Provided | W/CAPACITOR |
AXGY | Mounting Method | TAB SINGLE GROUP |
AFHM | Mounting Tab Width | 0.075 INCHES NOMINAL |
AKNA | Inclosure Type | FULLY INCLOSED |
BKPL | Rating Method | WINDING TURNS SINGLE COMPONENT SINGLE PRIMARY |
BKPL | Rating Method | WINDING TURNS SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
ABHY | Turn Quantity | 11-1/4 SINGLE COMPONENT SINGLE SECONDARY |
ABHY | Turn Quantity | 199-3/4 SINGLE COMPONENT SINGLE PRIMARY |
CQPZ | Winding Conductor Size | 0.00500 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
CQPZ | Winding Conductor Size | 0.00500 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE SECONDARY |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
TTQY | Terminal Type And Quantity | 5 PIN |