5950-01-111-0158

TRANSFORMER,AUDIO FREQUENCY


5950-01-111-0158 (5950011110158, 011110158)
Part Numbers (2 listings): M27/197-07 | MIL-T-27/197 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 9 Apr 1981

Unit Weight: 0.5 lbs

Unit Size: 2.5in x 1.6in x 1.6in

Unit Pack Cube: 0.003 cu ft

Replacement NSN:

5950-00-654-1472

Replacement Date: 28 Nov 1980

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-01-111-0158 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M27/197-072 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-T-27/1974 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5950-01-111-0158 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950011110158A058B000780X1APA9 Apr 1981
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

011110158

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-01-111-0158

A058B0

Federal Item Identification Guide (FIIG_4065)

00780

Item Naming Code (INC_4080)

9 Apr 1981

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5950-01-111-0158 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Nov 1998
N9BNN9ND5HZHDHD1 Jun 2006
Code Definitions

5

Acquisition Method Code (AMC_2871)


Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5950-01-111-0158 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4223TXDM27/197-07  81349   CAGE/81349
4413TXDMIL-T-27/197  81349   CAGE/81349
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-01-111-0158 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX128 Nov 1980 5950006541472 1 Dec 1980
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

28 Nov 1980

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5950-00-654-1472

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

1 Dec 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-01-111-0158 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-01-111-0158 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSVU0ZEA0
DNSMSJU1EA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

1

Quantity Unit Pack (QUP_6106)


1

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5950-01-111-0158 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA0.5 lbs2.5in x 1.6in x 1.6in0.003 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00GB000D3EC00QQUO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.5 lbs

Unit Pack Weight (UP_WT_5153)

2.5in x 1.6in x 1.6in

Unit Pack Size (UP_SZ_5154)

0.003 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

GB

Wrapping Material Code (WRAP_MAT_CD_5163)


MIL-PRF-121, greaseproof, waterproof barrier

00

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


No requirement

0

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Not Applicable

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

EC

Intermediate Container Code (INTMD_CTNR_CD_5167)


ASTM-D5118, Type CF, Class domestic, corrugated fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-01-111-0158 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAQBody Length1.625 INCHES NOMINAL
ADATBody Width1.625 INCHES MAXIMUM
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating40.0 HERTZ MINIMUM SINGLE COMPONENT AND 20.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
ACZFMaximum Transformer Power Rating1.0 WATTS SINGLE COMPONENT
AKPVMounting Facility Quantity4 SINGLE GROUP
ABTBMounting Hole Diameter0.144 INCHES NOMINAL SINGLE GROUP
AXGYMounting MethodFLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP
ACYWImpedance Rating In Ohms2500.0 NOMINAL SINGLE COMPONENT ALL PRIMARY
ACYWImpedance Rating In Ohms500.0 NOMINAL SINGLE COMPONENT ALL SECONDARY
AKNAInclosure TypeHERMETICALLY SEALED
AARGReliability IndicatorNOT ESTABLISHED
ABKWOverall Height2.515 INCHES NOMINAL
BPLCWinding Function And Quantity2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current8.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL PRIMARY
ZZZKSpecification/Standard Data81349-MIL-T-27/197 GOVERNMENT SPECIFICATION
TTQYTerminal Type And Quantity8 TAB, SOLDER LUG
TESTTest Data Document81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top