5950-01-123-0660

TRANSFORMER ASSEMBLY


5950-01-123-0660 (5950011230660, 011230660)
Part Numbers (6 listings): 984882-2B | 861897E | 321-18050-04 | 11364 | ST30852 | 321-18050-01 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 5 Dec 1981

Replacement NSN:

5950-01-254-2151

Replacement Date: 20 Dec 1987

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-01-123-0660 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
984882-2B3 - Design Control Reference2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
861897E5 - Replaced / Discontinued2 - Production ItemRAYTHEON COMPANY  82577    CAGE 82577  
321-18050-045 - Replaced / Discontinued2 - Production ItemOECO, LLC  95266      
113645 - Replaced / Discontinued2 - Production ItemSORA POWER INC.  55196      
ST308525 - Replaced / Discontinued9 - No Longer UsedSTERLING TRANSFORMER CORP  97102      
321-18050-015 - Replaced / Discontinued9 - No Longer UsedOECO, LLC  95266      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5950-01-123-0660 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950011230660A058B000449X1APA5 Dec 1981
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

011230660

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-01-123-0660

A058B0

Federal Item Identification Guide (FIIG_4065)

00449

Item Naming Code (INC_4080)

5 Dec 1981

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5950-01-123-0660 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZC011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5950-01-123-0660 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
321TX984882-2B  82577   CAGE/82577
525TX11364  55196  
525TX861897E  82577   CAGE/82577
525TX321-18050-04  95266  
595TXBST30852  97102  
595TXB321-18050-01  95266  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-01-123-0660 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX020 Dec 1987 5950012542151 16 Dec 1987
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

20 Dec 1987

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5950-01-254-2151

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

16 Dec 1987

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-01-123-0660 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-01-123-0660 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU0EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-01-123-0660 Submit RFQ
MRCDecoded RequirementClear Text Reply
AEJNDistance Between Mounting Facility Centers5.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZBFrequency Rating10.0 KILOHERTZ NOMINAL ALL COMPONENTS
AKPVMounting Facility Quantity2 SINGLE GROUP
ABTBMounting Hole Diameter0.187 INCHES NOMINAL SINGLE GROUP
AXGYMounting MethodUNTHREADED HOLE SINGLE GROUP
AKNAInclosure TypeFULLY INCLOSED
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
BKPLRating MethodELECTRICAL ALL COMPONENTS ALL PRIMARY
BKPLRating MethodELECTRICAL ALL COMPONENTS ALL SECONDARY
AARGReliability IndicatorNOT ESTABLISHED
ABKWOverall Height3.570 INCHES MAXIMUM
ABHPOverall Length4.750 INCHES MAXIMUM
BPLCWinding Function And Quantity1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT
BPLCWinding Function And Quantity1 PRIMARY 2ND COMPONENT AND 3 SECONDARY 2ND COMPONENT
CRBZWinding Operating Current10.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 1ST SECONDARY
CRBZWinding Operating Current1.2 AMPERES AC MAXIMUM 2ND COMPONENT 2ND SECONDARY
CRBZWinding Operating Current3.0 AMPERES AC MAXIMUM 1ST COMPONENT 4TH SECONDARY
CRBZWinding Operating Current35.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 3RD SECONDARY
CRBZWinding Operating Current35.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 3RD SECONDARY
CRBZWinding Operating Current50.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 1ST SECONDARY
CRBZWinding Operating Current50.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage12.02 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage12.02 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY
CWJSWinding Operating Voltage130.00 DC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY AND 133.50 DC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage149.88 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY
CWJSWinding Operating Voltage178.16 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY AND 195.83 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY AND 213.51 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY
CWJSWinding Operating Voltage28.28 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY
CWJSWinding Operating Voltage32.52 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY
CWJSWinding Operating Voltage70.70 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY
ACZXWinding Shielding MethodINTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS
TTQYTerminal Type And Quantity35 WIRE LEAD


Back to Top