5950-01-137-2297

TRANSFORMER,POWER


5950-01-137-2297 (5950011372297, 011372297)
Part Numbers (6 listings): 5024020308 | BX-9282 | 828-206 | C14161 | 40445 | PEI7138 |
Summary

FSG 59 / FSC 5950

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 23 Aug 1982

Unit Weight: 40.0 lbs

Unit Size: 6in x 8in x 8in

Unit Pack Cube: 0.222 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5950-01-137-2297 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
50240203083 - Design Control Reference2 - Production ItemRIIMIC, LLC  12338      
BX-92825 - Replaced / Discontinued1 - Incomplete Part NumberBALTIMORE TRANSFORMER COMPANY  85323      
828-2065 - Replaced / Discontinued2 - Production ItemMAGNETIC WINDINGS COMPANY INC  76095      
C141615 - Replaced / Discontinued2 - Production ItemELECTRONIC TRANSFORMER CORP.  72149      
404455 - Replaced / Discontinued2 - Production ItemCOAST/ADVANCED CHIP MAGNETICS, INC.  22558    CAGE 22558  
PEI 71385 - Replaced / Discontinued2 - Production ItemPRECISION ELECTRONICS, INC.  13483    CAGE 13483  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5950-01-137-2297 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595950011372297A058B032496X1APA23 Aug 1982
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5950

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Coils and Transformers

011372297

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5950-01-137-2297

A058B0

Federal Item Identification Guide (FIIG_4065)

32496

Item Naming Code (INC_4080)

23 Aug 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5950-01-137-2297 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YW011 Apr 1991
C911C0073C1 Jun 2006
FXGXFXTX3CZSX1 Jun 2006
N9BNN9ND3CZHDGTHD1 Jun 2006
ZU011 May 2008
ZM011 Feb 2015
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5950-01-137-2297 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32ATX5024020308  12338  
515TXBX-9282  85323  
525ZZPEI 7138  13483   CAGE/13483
525TX40445  22558   CAGE/22558
525ZZC14161  72149  
525TX828-206  76095  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5950-01-137-2297 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597023 Aug 1982
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

23 Aug 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5950-01-137-2297 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX595Z9AHZW063420Z35355TRANSFORMERS-NOI-OR-TRANSFORMER-PAR
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

595

Water Commodity Code (WRT_CMDTY_CD_9275)


Transformer, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063420

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35355

Uniform Freight Classification (UFC_CD_MODF_3040)

TRANSFORMERS-NOI-OR-TRANSFORMER-PAR

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5950-01-137-2297 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSJU1NEA0
DNSMSJU1EA0
DSSMSJU1NEA0
GPSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5950-01-137-2297 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP41100040.0 lbs6in x 8in x 8in0.222 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00CAJCXEE0000FFM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

40.0 lbs

Unit Pack Weight (UP_WT_5153)

6in x 8in x 8in

Unit Pack Size (UP_SZ_5154)

0.222 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

CA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-203, kraft wrapping paper

JC

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

EE

Unit Container Code (UNIT_CTNR_CD_5166)


ASTM-D5118, Type CF, Class weather resistant, single wall, corrugated fiberboard box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

F

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5950-01-137-2297 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height5.105 INCHES MINIMUM AND 5.125 INCHES MAXIMUM
ADAQBody Length5.440 INCHES MAXIMUM
ADATBody Width5.075 INCHES MINIMUM AND 5.130 INCHES MAXIMUM
ABKQCenter To Center Distance Between Mounting Facilities Parallel To Length4.360 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 4.390 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
ABKRCenter To Center Distance Between Mounting Facilities Parallel To Width4.110 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 4.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
CBBLFeatures ProvidedCOLOR CODED LEAD AND TINNED WIRE LEADS
ACZBFrequency Rating48.0 HERTZ MINIMUM SINGLE COMPONENT AND 62.0 HERTZ MAXIMUM SINGLE COMPONENT
AKPVMounting Facility Quantity4 ALL GROUPINGS
AXGYMounting MethodTHREADED HOLE ALL GROUPINGS
CQJXNominal Thread Size0.250 INCHES ALL GROUPINGS
AKNAInclosure TypeFULLY INCLOSED
ACZCInput-Output Phase RelationshipSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AARGReliability IndicatorNOT ESTABLISHED
FEATSpecial FeaturesTHREE PRIMARY WINDINGS; THREE SECONDARY WINDINS; MULTIPLE TAPS WITH CENTER TAP THIRD PRIMARY
BPLCWinding Function And Quantity3 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CRBZWinding Operating Current10.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRBZWinding Operating Current1.5 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
CRBZWinding Operating Current750.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWinding Operating Voltage12.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWinding Operating Voltage113.27 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
CWJSWinding Operating Voltage115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 132.25 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
CWJSWinding Operating Voltage20.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWinding Operating Voltage34.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
CRMJWinding Power Rating30.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRMJWinding Power Rating340.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRMJWinding Power Rating9.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
TTQYTerminal Type And Quantity17 WIRE LEAD
THSDThread Series DesignatorUNC ALL GROUPINGS


Back to Top