5961-00-022-5670

TRANSISTOR


5961-00-022-5670 (5961000225670, 000225670)
Part Numbers (25 listings): JAN2N3439L | MIL-PRF-19500/368 | 2N3439 | JAN2N3439A | 4E4850/15-0002 | 0024123127499 | 5008-911 | JAN2N3439 | 418915-1 | 1854-3439 | 2396244 | 2396244-1 | 13-1023 | 62-903-439 | 8880300003-1 | 2-24417-0010 | 0000-10-0024 | 26825-1 | 4192800-253 | 640088 | 2N349 | 38640130 | 2N3439S | 2N1711 | TX2N3439 |
Summary

FSG 59 / FSC 5961

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 13 May 1968

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.003 cu ft

Replacement NSN:

5961-00-055-7897

Replacement Date: 3 Aug 1971

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-00-022-5670 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
JAN2N3439L2 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-PRF-19500/3684 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
2N34395 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
2N34395 - Replaced / Discontinued9 - No Longer UsedIT ENTERPRISE  3GW96      
JAN2N3439L5 - Replaced / Discontinued9 - No Longer UsedAVNET, INC.  1W091      
JAN2N3439A5 - Replaced / Discontinued9 - No Longer UsedADELCO ELEKTRONIK GMBH  C7191    CAGE C7191  
JAN2N3439L5 - Replaced / Discontinued9 - No Longer UsedMICROSEMI CORP. - MASSACHUSETTS  43611      
4E4850/15-00025 - Replaced / Discontinued9 - No Longer UsedHAMILTON SUNDSTRAND CORPORATION  73030      
002 4123 1274995 - Replaced / Discontinued9 - No Longer UsedTE KA DE FELTEN &  D8770      
5008-9115 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  05869    CAGE 05869  
JAN2N3439L5 - Replaced / Discontinued9 - No Longer UsedKOEHLKE COMPONENTS INC  5N063      
JAN2N34395 - Replaced / Discontinued9 - No Longer UsedSOLITRON DEVICES, INC.  21845    CAGE 21845  
JAN2N3439L5 - Replaced / Discontinued9 - No Longer UsedSOLITRON DEVICES, INC.  21845    CAGE 21845  
2N34395 - Replaced / Discontinued9 - No Longer UsedLOCKHEED MARTIN CORP  49671    CAGE 49671  
418915-15 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  96214    CAGE 96214  
2N34395 - Replaced / Discontinued9 - No Longer UsedMOTOROLA GMBH  C0187      
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  13715    CAGE 13715  
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
1854-3439C - Advisory Reference1 - Incomplete Part NumberBR COMMUNICATIONS INC  33783      
2396244C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  49671    CAGE 49671  
2396244C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  49671    CAGE 49671  
2396244-1C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORP  49671    CAGE 49671  
13-1023C - Advisory Reference1 - Incomplete Part NumberCOMPUTER PRODUCTS INC  61852      
62-903-439C - Advisory Reference1 - Incomplete Part NumberCOMMUNICATIONS & POWER INDUSTRIES  99313    CAGE 99313  
2N3439C - Advisory Reference1 - Incomplete Part NumberVEECO INSTRUMENTS INC  80103    CAGE 80103  
8880300003-1C - Advisory Reference1 - Incomplete Part NumberNAVCOM DEFENSE ELECTRONICS, INC.  57057    CAGE 57057  
2N3439C - Advisory Reference1 - Incomplete Part NumberJOINT ELECTRON DEVICE ENGINEERING  07688      
2-24417-0010C - Advisory Reference1 - Incomplete Part NumberTE CONNECTIVITY NETWORKS, INC.  00144    CAGE 00144  
0000-10-0024C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  49956    CAGE 49956  
26825-1C - Advisory Reference1 - Incomplete Part NumberTYCO ELECTRONICS CORPORATION  00779    CAGE 00779  
4192800-253C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  05869    CAGE 05869  
640088C - Advisory Reference1 - Incomplete Part NumberLOGIMETRICS INC  33013      
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N3439C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N349C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
JAN2N3439C - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
38640130C - Advisory Reference1 - Incomplete Part NumberDELTYME CORPORATION  52297      
2N3439SC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
2N3439C - Advisory Reference1 - Incomplete Part NumberJOINT ARMY-NAVY SPECIFICATIONS  81350    CAGE 81350  
JAN2N3439C - Advisory Reference1 - Incomplete Part NumberJOINT ARMY-NAVY SPECIFICATIONS  81350    CAGE 81350  
2N1711C - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
TX2N3439C - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5961-00-022-5670 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961000225670A110A020588X1ANBA013 May 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

000225670

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-00-022-5670

A110A0

Federal Item Identification Guide (FIIG_4065)

20588

Item Naming Code (INC_4080)

13 May 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5961-00-022-5670 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G28000C1 Apr 1991
G86000C1 Apr 1991
YB011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZB011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZN011 Apr 1991
ZP011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZW011 Apr 1991
ZX011 Apr 1991
YW011 Jul 1993
YA011 Dec 1999
WP011 Jan 2005
WB011 Feb 2005
MC49MC131TZPA1 Aug 2006
N9BNN9ND1TZGHGTJBHXHSHD1 Aug 2006
RGX1R4791TTR1 Aug 2006
S911S0071TZXN1 Aug 2006
A918A1961TZCDBDCL1 Aug 2006
BGX1BTX11T1 Aug 2006
FXGXFXTX1TZSX1 Aug 2006
G17XG17E1T1 Aug 2006
YK011 Jan 2015
YS011 Feb 2015
YY011 Feb 2015
ZM011 Feb 2015
YC011 Jul 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

T

Acquisition Method Suffix Code (AMSC_2876)


Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

XN

Item Management Coding Activity (IMC_ACTY_2748)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

JBCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Mechanicsburg, PA 17055-0788

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

TRCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


National Weather Service Cataloging Activity, Battle Creek MI 49037-3084

BD

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 5961-00-022-5670 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
22ETXJAN2N3439L  81349   CAGE/81349
41EZZMIL-PRF-19500/368  81349   CAGE/81349
159348B2N3439  81349   CAGE/81349
3595TXB418915-1  96214   CAGE/96214
45949ZB12N3439  49671   CAGE/49671
45999ZBJAN2N3439L  5N063  
1591TXB4E4850/15-0002  73030  
3595TXB5008-911  05869   CAGE/05869
45999ZBJAN2N3439L  1W091  
45999ZBJAN2N3439  21845   CAGE/21845
45999ZBJAN2N3439L  21845   CAGE/21845
45999ZB2N3439  3GW96  
45999ZBJAN2N3439L  43611  
35939ZB2N3439  C0187  
596ZGB1JAN2N3439A  C7191   CAGE/C7191
4593ZGB002 4123 127499  D8770  
C1ATUAW2396244  49671   CAGE/49671
C15TXAF2396244-1  49671   CAGE/49671
C15TXAF640088  33013  
C15ZZS41854-3439  33783  
C15ZZS42N3439  07263   CAGE/07263
C16ZZAC2N349  07263   CAGE/07263
C16ZZAC2N3439  07688  
C16ZZAC2N3439  13715   CAGE/13715
C11PAAD2-24417-0010  00144   CAGE/00144
C15TXAF26825-1  00779   CAGE/00779
C16ZZAC2N3439S  04713   CAGE/04713
1C15ZXD4192800-253  05869   CAGE/05869
C16ZZAC2N3439  80103   CAGE/80103
C16ZZAC2N1711  81349   CAGE/81349
C15TXAF13-1023  61852  
1C1448BAH0000-10-0024  49956   CAGE/49956
1C1548B38640130  52297  
C15TXAF8880300003-1  57057   CAGE/57057
C16ZZAC62-903-439  99313   CAGE/99313
C16ZZACJAN2N3439  81349   CAGE/81349
C16ZZACTX2N3439  81349   CAGE/81349
C16ZZAC2N3439  81350   CAGE/81350
C16ZZACJAN2N3439  81350   CAGE/81350
Code Definitions

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

1

Reference Number Justification Code (RNJC_2750)


Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

S4

Service / Agency Designator Code (SADC_4672)


Army / Air Force / Navy / Marine Corps / Coast Guard / General Services Administration

AC

Service / Agency Designator Code (SADC_4672)


Navy

PA

Reference Number Action Activity Code (RNAAC_2900)


Marine Corps Logistics Base, Albany, GA 31704-1128

AD

Service / Agency Designator Code (SADC_4672)


Marine Corps

ZX

Reference Number Action Activity Code (RNAAC_2900)


NAMSA (LI Division)

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-00-022-5670 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX13 Aug 1971 5961000557897 17 Nov 1968
1TX03TX117 Oct 1980 5961004892021 17 Nov 1968
1TX03TX13 Feb 1969 5961009253762 17 Nov 1968
1TX03TX07 Jan 1985 5961010266663 17 Nov 1968
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

3 Aug 1971

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

17 Oct 1980

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

3 Feb 1969

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

7 Jan 1985

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5961-00-055-7897

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5961-00-489-2021

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5961-00-925-3762

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5961-01-026-6663

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

17 Nov 1968

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-00-022-5670 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72D39AHZW063025Z34525SEMICONDUCTORS-DEVICES-NOI-ETC
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063025

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34525

Uniform Freight Classification (UFC_CD_MODF_3040)

SEMICONDUCTORS-DEVICES-NOI-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5961-00-022-5670 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSDU1ZEA0
DFSMSDU1NEA0
DMSMSDU1ZEA0
DNSMSDU1EA0
DSSMSDU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5961-00-022-5670 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPGX1AAA0.1 lbs0.003 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD3ZZQQ6M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.003 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

6

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-00-022-5670 Submit RFQ
MRCDecoded RequirementClear Text Reply
ALBAElectrode Internally-Electrically Connected To CaseCOLLECTOR
CTQXCurrent Rating Per Characteristic1.00 AMPERES SOURCE CUTOFF CURRENT MAXIMUM
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
CTSGMaximum Operating Temp Per Measurement Point200.0 DEG CELSIUS AMBIENT AIR
AXGYMounting MethodTERMINAL
ADAVOverall Diameter0.335 INCHES MINIMUM AND 0.370 INCHES MAXIMUM
CTMZSemiconductor MaterialSILICON
ABBHInclosure MaterialMETAL
CTRDPower Rating Per Characteristic5.0 WATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR PRESET
ABHPOverall Length0.240 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
CTQNVoltage Rating In Volts Per Characteristic450.0 MAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN AND 450.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN AND 7.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN
ZZZKSpecification/Standard Data81349-MIL-PRF-19500/368 GOVERNMENT SPECIFICATION
AYQSTerminal Circle Diameter0.200 INCHES NOMINAL
ABJTTerminal Length1.500 INCHES MINIMUM
TTQYTerminal Type And Quantity3 UNINSULATED WIRE LEAD
TESTTest Data Document81349-MIL-PRF-19500 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top
Back to Top