5961-00-082-3401

SEMICONDUCTOR DEVICE,DIODE


5961-00-082-3401 (5961000823401, 000823401)
Part Numbers (8 listings): P100-3209R | 1N3209R | RELEASE3291 | 0405190000 | 174-20988-12 | 1901-0346 | 23-00141 | 013-974 |
Summary

FSG 59 / FSC 5961

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1961

Unit Weight: None

Unit Size:

Unit Pack Cube: None

Replacement NSN:

5961-00-958-6724

Replacement Date: 24 Jan 1991

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-00-082-3401 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
P100-3209R3 - Design Control Reference2 - Production ItemLA MARCHE MFG. CO.  92731    CAGE 92731  
1N3209R3 - Design Control Reference2 - Production ItemELECTRONIC INDUSTRIES ASSOCIATION  80131    CAGE 80131  
RELEASE32915 - Replaced / Discontinued1 - Incomplete Part NumberELECTRONIC INDUSTRIES ASSOCIATION  80131    CAGE 80131  
1N3209R5 - Replaced / Discontinued2 - Production ItemELECTRONIC TRANSISTORS CORP  12045      
1N3209R5 - Replaced / Discontinued2 - Production ItemFMC TECHNOLOGIES INC  58849    CAGE 58849  
04051900005 - Replaced / Discontinued2 - Production ItemRIIMIC, LLC  12338      
1N3209R5 - Replaced / Discontinued2 - Production ItemST-SEMICON INC  51589      
1N3209R5 - Replaced / Discontinued2 - Production ItemSOLID STATE DEVICES, INC.  30043    CAGE 30043  
174-20988-125 - Replaced / Discontinued2 - Production ItemGTE COMMUNICATION SYSTEMS CORP  04773    CAGE 04773  
1N3209R5 - Replaced / Discontinued2 - Production ItemINTERNATIONAL RECTIFIER CORPORATION  81483    CAGE 81483  
1N3209R5 - Replaced / Discontinued2 - Production ItemLABORATORY DIAGNOSTICS CO INC  16759      
1N3209R5 - Replaced / Discontinued2 - Production ItemSOLITRON DEVICES, INC.  21845    CAGE 21845  
1N3209R5 - Replaced / Discontinued2 - Production ItemEDAL INDUSTRIES, INC.  06288      
1N3209R5 - Replaced / Discontinued2 - Production ItemWESTINGHOUSE ELECTRIC CORP  05277    CAGE 05277  
1N3209R5 - Replaced / Discontinued2 - Production ItemITT SEMICONDUCTORS DIV  14433    CAGE 14433  
1901-03465 - Replaced / Discontinued2 - Production ItemAVAGO TECHNOLOGIES U.S. INC.  50434    CAGE 50434  
1N3209R5 - Replaced / Discontinued2 - Production ItemSEMICON COMPONENTS INC  11961      
1N3209R5 - Replaced / Discontinued2 - Production ItemINTERNATIONAL DIODE CORP  16068      
1N3209R5 - Replaced / Discontinued9 - No Longer UsedGENERAL ELECTRIC CO  03508    CAGE 03508  
23-001415 - Replaced / Discontinued9 - No Longer UsedFRIGIKING DIVISION OF  16551      
1N3209R5 - Replaced / Discontinued9 - No Longer UsedFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
013-9745 - Replaced / Discontinued9 - No Longer UsedAMPEX SYSTEMS CORP  92739    CAGE 92739  
1901-03465 - Replaced / Discontinued9 - No Longer UsedHEWLETT PACKARD CO  28480    CAGE 28480  
1N3209R5 - Replaced / Discontinued9 - No Longer UsedGILBERT ENGINEERING CO INC/INCON  03877    CAGE 03877  
1N3209R5 - Replaced / Discontinued9 - No Longer UsedCOOPER INDUSTRIES INC  94988    CAGE 94988  
1N3209RC - Advisory Reference1 - Incomplete Part NumberON SEMICONDUCTOR CORPORATION  5V1P1    CAGE 5V1P1  
1N3209RC - Advisory Reference1 - Incomplete Part NumberON SEMICONDUCTOR CORPORATION  5V1P1    CAGE 5V1P1  
1N3209RC - Advisory Reference1 - Incomplete Part NumberON SEMICONDUCTOR CORPORATION  5V1P1    CAGE 5V1P1  
013-974C - Advisory Reference1 - Incomplete Part NumberAMPEX DATA SYSTEMS CORPORATION  0PN68      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5961-00-082-3401 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961000823401A110A020589X1ANA1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

000823401

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-00-082-3401

A110A0

Federal Item Identification Guide (FIIG_4065)

20589

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5961-00-082-3401 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G07000L1 Apr 1991
YJ011 Apr 1991
YW011 Apr 1991
ZC011 Apr 1991
ZH011 Apr 1991
ZP011 Apr 1991
ZU011 Apr 1991
YB011 Feb 1994
ZR011 Jul 1997
ZW011 Nov 2005
YK011 Jan 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5961-00-082-3401 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3325HDDP100-3209R  92731   CAGE/92731
3323TXD1N3209R  80131   CAGE/80131
3513TXDRELEASE3291  80131   CAGE/80131
3523TXD1N3209R  81483   CAGE/81483
52548174-20988-12  04773   CAGE/04773
3523TXD1N3209R  05277   CAGE/05277
3523TXD1N3209R  06288  
3523TXD1N3209R  11961  
3523TXD1N3209R  12045  
5269ZD0405190000  12338  
3523TXD1N3209R  14433   CAGE/14433
3523TXD1N3209R  16068  
3523TXD1N3209R  16759  
523TX1N3209R  21845   CAGE/21845
3523TXD1N3209R  30043   CAGE/30043
525ZZ1901-0346  50434   CAGE/50434
1523TXD1N3209R  51589  
523TX1N3209R  58849   CAGE/58849
3595TXB1901-0346  28480   CAGE/28480
3593TXB1N3209R  03508   CAGE/03508
3593TXB1N3209R  03877   CAGE/03877
3593TXB1N3209R  04713   CAGE/04713
3595TXB23-00141  16551  
45959ZB013-974  92739   CAGE/92739
3593TXB1N3209R  94988   CAGE/94988
4C15ZZD9F013-974  0PN68  
C13ZZ9X1N3209R  5V1P1   CAGE/5V1P1
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

9F

Service / Agency Designator Code (SADC_4672)


CAGE Status Change

9X

Service / Agency Designator Code (SADC_4672)


GIRDER


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-00-082-3401 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX0BTX024 Jan 1991 5961009586724 11 May 1984
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

24 Jan 1991

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5961-00-958-6724

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

11 May 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-00-082-3401 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
72DZ9AHZW063025Z34525SEMICONDUCTORS-DEVICES-NOI-ETC
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063025

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34525

Uniform Freight Classification (UFC_CD_MODF_3040)

SEMICONDUCTORS-DEVICES-NOI-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5961-00-082-3401 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5961-00-082-3401 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APZZXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XQQO
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-00-082-3401 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTQXCurrent Rating Per Characteristic250.00 AMPERES MAXIMUM PEAK FORWARD SURGE CURRENT
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
CTSGMaximum Operating Temp Per Measurement Point175.0 DEG CELSIUS CASE
AKPVMounting Facility Quantity1
AXGYMounting MethodTHREADED STUD
CQJXNominal Thread Size0.250 INCHES
ABBHInclosure MaterialMETAL
CTMZSemiconductor MaterialSILICON
ABHPOverall Length1.022 INCHES MINIMUM AND 1.253 INCHES MAXIMUM
CCDGOverall Width Across Flats0.423 INCHES MINIMUM AND 0.438 INCHES MAXIMUM
FEATSpecial FeaturesREVERSED POLARITY
THSDThread Series DesignatorUNF
CTQNVoltage Rating In Volts Per Characteristic100.0 MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE
ZZZKSpecification/Standard Data80131-RELEASE3291 PROFESSIONAL/INDUSTRIAL ASSOCIATION SPECIFICATION
TTQYTerminal Type And Quantity1 TAB, SOLDER LUG AND 1 THREADED STUD


Back to Top
Back to Top