5961-00-105-7636

TRANSISTOR


5961-00-105-7636 (5961001057636, 001057636)
Part Numbers (24 listings): 2N4923 | RELEASE5441 | M9618 | 20-4923 | 06-01-30-657 | 57560-900-1 | 7314000 | 821801 | C0M1710 | B1297 | 440021 | 98-4457 | 2N4923A | 1854-0347 | 1-230057-3 | 9006502-01 | 373762-0003 | 76-11-22 | 76-11-23 | 16766748-006 | 4271-0722 | 352-0782-030 | 2064801 | 663-00107 |
Summary

FSG 59 / FSC 5961

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 12 Jul 1968

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.001 cu ft

Replacement NSN:

5961-00-003-5748

Replacement Date: 17 Mar 1990

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-00-105-7636 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2N49233 - Design Control Reference2 - Production ItemELECTRONIC INDUSTRIES ASSOCIATION  80131    CAGE 80131  
RELEASE54415 - Replaced / Discontinued1 - Incomplete Part NumberELECTRONIC INDUSTRIES ASSOCIATION  80131    CAGE 80131  
M96185 - Replaced / Discontinued1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
20-49235 - Replaced / Discontinued2 - Production ItemTHALES AVIONICS ELECTRICAL  F0296    CAGE F0296  
06-01-30-6575 - Replaced / Discontinued2 - Production ItemB.V. NEDERLANDSE INSTRUMENTEN  H0973      
57560-900-15 - Replaced / Discontinued2 - Production ItemMAGNETI MARELLI FRANCE  F0423      
73140005 - Replaced / Discontinued2 - Production ItemITW LIMITED T/A HOUCHIN AEROSPACE  K3470      
8218015 - Replaced / Discontinued2 - Production ItemCONTROL TECHNIQUES DYNAMICS LTD  K4308      
C0M17105 - Replaced / Discontinued2 - Production ItemMEGGITT (UK) LTD  K0100      
B12975 - Replaced / Discontinued2 - Production ItemJERMYN DISTRIBUTION  K1935      
4400215 - Replaced / Discontinued2 - Production ItemSYQWEST, INC.  33642      
98-44575 - Replaced / Discontinued2 - Production ItemELTEK ENERGY LLC  31751      
2N49235 - Replaced / Discontinued2 - Production ItemADELCO ELEKTRONIK GMBH  C7191    CAGE C7191  
2N4923A5 - Replaced / Discontinued9 - No Longer UsedADELCO ELEKTRONIK GMBH  C7191    CAGE C7191  
1854-03475 - Replaced / Discontinued9 - No Longer UsedHEWLETT PACKARD CO  28480    CAGE 28480  
57560-900-15 - Replaced / Discontinued9 - No Longer UsedJAEGER ETS  F0216      
2N49235 - Replaced / Discontinued9 - No Longer UsedFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
1854-0347C - Advisory Reference1 - Incomplete Part NumberAGILENT TECHNOLOGIES, INC.  1LQK8    CAGE 1LQK8  
1854-0347C - Advisory Reference1 - Incomplete Part NumberAGILENT TECHNOLOGIES, INC.  1LQK8    CAGE 1LQK8  
1854-0347C - Advisory Reference1 - Incomplete Part NumberAGILENT TECHNOLOGIES, INC.  1LQK8    CAGE 1LQK8  
1-230057-3C - Advisory Reference1 - Incomplete Part NumberGOULD INSTRUMENT SYSTEMS INC  96795    CAGE 96795  
9006502-01C - Advisory Reference1 - Incomplete Part NumberH & E VENTURE, LLC  13799      
2N4923C - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07933    CAGE 07933  
373762-0003C - Advisory Reference1 - Incomplete Part NumberLUCENT TECHNOLOGIES INC  06KW9    CAGE 06KW9  
76-11-22C - Advisory Reference1 - Incomplete Part NumberMIDWAY AIRCRAFT INSTRUMENT  99808      
76-11-23C - Advisory Reference1 - Incomplete Part NumberMIDWAY AIRCRAFT INSTRUMENT  99808      
16766748-006C - Advisory Reference1 - Incomplete Part NumberSYPRIS ELECTRONICS, LLC  28009    CAGE 28009  
373762-0003C - Advisory Reference1 - Incomplete Part NumberSYPRIS ELECTRONICS, LLC  14028    CAGE 14028  
4271-0722C - Advisory Reference1 - Incomplete Part NumberGENRAD INC  24655      
352-0782-030C - Advisory Reference1 - Incomplete Part NumberROCKWELL COLLINS, INC.  13499    CAGE 13499  
2064801E - Replace Reference Number8 - Replacement NSNNAVAIR AND NAVSEA MANAGED  10001      
663-00107E - Replace Reference Number8 - Replacement NSNDATRON THE INSTRUMENTS INC  13488    CAGE 13488  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

E - Replace Reference Number

Reference Number Category Code (DRN_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

8 - Replacement NSN

Reference Number Variation Code (DRN_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.


FLIS - SEG A - IDENTIFICATION | NSN 5961-00-105-7636 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961001057636A110A020588X1ANBU12 Jul 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

001057636

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-00-105-7636

A110A0

Federal Item Identification Guide (FIIG_4065)

20588

Item Naming Code (INC_4080)

12 Jul 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5961-00-105-7636 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G28000C1 Apr 1991
G86000C1 Apr 1991
G90000L1 Apr 1991
ZA011 Apr 1991
ZB011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZN011 Apr 1991
ZP011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
YB011 Apr 1991
YJ011 Apr 1991
ZX011 Apr 1991
YW011 Aug 1997
ZW011 Nov 1998
YA011 Dec 1999
WP011 Oct 2003
WB011 Feb 2005
A918A1961GZCDBDCL1 Aug 2006
FXGXFXTX1GZSX1 Aug 2006
N9BNN9ND1GZGHGTKEHSHD1 Aug 2006
RGX1R4791GTR1 Aug 2006
S911S0071GZXN1 Aug 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

XN

Item Management Coding Activity (IMC_ACTY_2748)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

HSCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

TRCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


National Weather Service Cataloging Activity, Battle Creek MI 49037-3084

BD

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 5961-00-105-7636 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3323TXD2N4923  80131   CAGE/80131
3513TXDRELEASE5441  80131   CAGE/80131
516TXM9618  04713   CAGE/04713
352548D98-4457  31751  
352548D440021  33642  
526ZFD20-4923  F0296   CAGE/F0296
524ZFB57560-900-1  F0423  
3523ZGD06-01-30-657  H0973  
3522ZKDC0M1710  K0100  
3522ZKDB1297  K1935  
4524ZKD7314000  K3470  
4524ZKD821801  K4308  
4526ZGA2N4923  C7191   CAGE/C7191
4596ZGB2N4923A  C7191   CAGE/C7191
3594ZFD57560-900-1  F0216  
3593TXD2N4923  04713   CAGE/04713
3595TXB1854-0347  28480   CAGE/28480
C16ZZAC1-230057-3  96795   CAGE/96795
4C16TXD76-11-22  99808  
4C16TXD76-11-23  99808  
C16ZZAC373762-0003  06KW9   CAGE/06KW9
4C15TXD2N4923  07933   CAGE/07933
C16ZZAC352-0782-030  13499   CAGE/13499
C1448AH9006502-01  13799  
C16ZZAC373762-0003  14028   CAGE/14028
C15ZZ9X1854-0347  1LQK8   CAGE/1LQK8
C16ZZAC4271-0722  24655  
C16ZZAC16766748-006  28009   CAGE/28009
1E81HDA2064801  10001  
4E859ZD663-00107  13488   CAGE/13488
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

ZF

Reference Number Action Activity Code (RNAAC_2900)


France

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZK

Reference Number Action Activity Code (RNAAC_2900)


United Kingdom

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration

9X

Service / Agency Designator Code (SADC_4672)


GIRDER

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

E

Reference Number Category Code (RNCC_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

8

Reference Number Variation Code (RNVC_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-00-105-7636 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX117 Mar 1990 5961000035748 14 Aug 1971
1TX03TX117 Mar 1990 5961011021723 14 Aug 1971
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

17 Mar 1990

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5961-00-003-5748

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5961-01-102-1723

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

14 Aug 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-00-105-7636 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72D39AHZW063025Z34525SEMICONDUCTORS-DEVICES-NOI-ETC
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063025

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34525

Uniform Freight Classification (UFC_CD_MODF_3040)

SEMICONDUCTORS-DEVICES-NOI-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5961-00-105-7636 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZU1ZEA0
DFSMSZU1NEA0
DNSMSZU1EA0
DSSMSZU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5961-00-105-7636 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPZZXXX0.1 lbs0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XZZQQUO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-00-105-7636 Submit RFQ
MRCDecoded RequirementClear Text Reply
ALBAElectrode Internally-Electrically Connected To CaseCOLLECTOR
CTQXCurrent Rating Per Characteristic1.00 AMPERES SOURCE CUTOFF CURRENT MAXIMUM AND 1.00 AMPERES SOURCE CUTOFF CURRENT MINIMUM
CTSGMaximum Operating Temp Per Measurement Point165.0 DEG CELSIUS JUNCTION
AKPVMounting Facility Quantity1
AXGYMounting MethodUNTHREADED HOLE
CTMZSemiconductor MaterialSILICON
ABBHInclosure MaterialPLASTIC
ALASInternal ConfigurationJUNCTION CONTACT
CTRDPower Rating Per Characteristic30.0 WATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR MINIMUM
ABKWOverall Height0.130 INCHES MAXIMUM
ABHPOverall Length0.450 INCHES MAXIMUM
ABMKOverall Width0.330 INCHES MAXIMUM
FEATSpecial FeaturesJUNCTION PATTERN ARRANGEMENT: NPN
CTQNVoltage Rating In Volts Per Characteristic80.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN AND 5.0 MAXIMUM BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN AND 80.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN
TTQYTerminal Type And Quantity3 UNINSULATED WIRE LEAD


Back to Top
Back to Top