Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2N3054A | 3 - Design Control Reference | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | |
RELEASE6266 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | ELECTRONIC INDUSTRIES ASSOCIATION | 80131 | |
2N3054A | 5 - Replaced / Discontinued | 9 - No Longer Used | ELECTRONIC INDUSTRIES ASSOCIATION | 80131 | |
12281187 | 5 - Replaced / Discontinued | 9 - No Longer Used | US ARMY ARDEC RDECOM | 19200 | |
2N3054 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
510037 | C - Advisory Reference | 1 - Incomplete Part Number | BECHDON COMPANY, THE | 62035 | |
2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | JOINT ELECTRON DEVICE ENGINEERING | 07688 | |
76E5N317 | C - Advisory Reference | 1 - Incomplete Part Number | NAVY, UNITED STATES DEPARTMENT OF | 28687 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | ON SEMICONDUCTOR CORPORATION | 5V1P1 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | ON SEMICONDUCTOR CORPORATION | 5V1P1 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | ON SEMICONDUCTOR CORPORATION | 5V1P1 | |
JEDEC2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | ELECTRONIC INDUSTRIES ASSOCIATION | 80131 | |
2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | DILLINGHAM LEWIS | 81394 | |
1854-0265 | C - Advisory Reference | 1 - Incomplete Part Number | HEWLETT PACKARD CO | 28480 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | FAIRCHILD SEMICONDUCTOR CORP | 07263 | |
37868 | C - Advisory Reference | 1 - Incomplete Part Number | ENGELHARD CORP | 05301 | |
2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | L-3 COMMUNICATIONS WESTWOOD | 23905 | |
314743-00-6 | C - Advisory Reference | 1 - Incomplete Part Number | BRISTOL BABCOCK INC | 08664 | |
204009 | C - Advisory Reference | 1 - Incomplete Part Number | CIPHER DATA PRODUCTS INC | 32274 | |
1854-0072 | C - Advisory Reference | 1 - Incomplete Part Number | ELECTRONIC INDUSTRIES ASSOCIATION | 80131 | |
2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | SOLITRON DEVICES INC | 34677 | |
352-0581-010 | C - Advisory Reference | 1 - Incomplete Part Number | CUBIC DEFENSE APPLICATIONS, INC. | 94987 | |
2N3054A | C - Advisory Reference | 1 - Incomplete Part Number | INTERSIL CORPORATION | 34371 | |
421418 | C - Advisory Reference | 1 - Incomplete Part Number | TELEDYNE CAMERA SYSTEMS | 14440 | |
2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | LIVERMONT INC | 03887 | |
0N321974-1 | C - Advisory Reference | 1 - Incomplete Part Number | NATIONAL SECURITY AGENCY | 98230 | |
JAN2N3054 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | |
2N3045 | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5961 | 003618753 | A110A0 | 20588 | X | 1 | A | N | B | A | 27 Feb 1974 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
ZP01 | 1 Sep 1999 | |||||||||||||||||||||||||||||
ZF01 | 1 Sep 1999 | |||||||||||||||||||||||||||||
YA01 | 1 Aug 2000 | |||||||||||||||||||||||||||||
WP01 | 1 Mar 2005 | |||||||||||||||||||||||||||||
A918 | A196 | 1 | Z | Z | CD | AZ | CL | BF | 1 Aug 2006 | |||||||||||||||||||||
BGX1 | BTX1 | 1 | Z | 1 Aug 2006 | ||||||||||||||||||||||||||
C911 | C007 | 1 | Z | 1 Aug 2006 | ||||||||||||||||||||||||||
FXGX | FXTX | 1 | Z | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
G17X | G17E | 1 | Z | 1 Aug 2006 | ||||||||||||||||||||||||||
G26X | G26E | 1 | Z | 1 Aug 2006 | ||||||||||||||||||||||||||
MC49 | MC13 | 1 | Z | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 1 | Z | Z | KE | GT | KE | HS | HD | JV | 1 Aug 2006 | |||||||||||||||||||
RGX1 | R479 | 1 | Z | TR | 1 Aug 2006 | |||||||||||||||||||||||||
S911 | S007 | 1 | Z | Z | XN | 1 Aug 2006 | ||||||||||||||||||||||||
ZU01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
YW01 | 1 Sep 2008 | |||||||||||||||||||||||||||||
YS01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YC01 | 1 Jul 2015 | |||||||||||||||||||||||||||||
VK01 | 1 Feb 2017 | |||||||||||||||||||||||||||||
YD01 | 1 Mar 2017 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval ICP, Philadelphia, PA 19111
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Naval ICP, Philadelphia, PA 19111
Navy ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
National Weather Service Cataloging Activity, Battle Creek MI 49037-3084
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Strategic Systems Programs C/O Tracor Sys Engineering Rockville, MD 20850-1160
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | E | TX | D | 2N3054A | 04713 | |||||
1 | 5 | 1 | 3 | TX | D | RELEASE6266 | 80131 | |||||
1 | 5 | 9 | 3 | TX | B | 2N3054A | 80131 | |||||
5 | 9 | A | TX | B | 12281187 | 19200 | ||||||
5 | 9 | 3 | B | 2N3054 | 81349 | |||||||
C | 1 | 6 | ZZ | AC | 2N3054A | 81349 | ||||||
C | 1 | 6 | ZZ | AC | JAN2N3054 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054 | 81394 | ||||||
C | 1 | 6 | ZZ | AC | 352-0581-010 | 94987 | ||||||
C | 1 | 6 | ZZ | AC | 0N321974-1 | 98230 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054 | 03887 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054 | 23905 | ||||||
C | 1 | 6 | ZZ | AC | 1854-0265 | 28480 | ||||||
C | 1 | 6 | ZZ | AC | 76E5N317 | 28687 | ||||||
C | 1 | 6 | ZZ | AC | 204009 | 32274 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054A | 34371 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054 | 34677 | ||||||
C | 1 | E | ZZ | 9X | 2N3054A | 5V1P1 | ||||||
C | 1 | 6 | ZZ | AC | 510037 | 62035 | ||||||
C | 1 | 6 | ZZ | AC | 1854-0072 | 80131 | ||||||
C | 1 | 6 | ZZ | AC | JEDEC2N3054 | 80131 | ||||||
C | 1 | 6 | ZZ | AC | 2N3045 | 81349 | ||||||
C | 1 | 6 | ZZ | AC | 37868 | 05301 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054A | 07263 | ||||||
C | 1 | 6 | ZZ | AC | 2N3054 | 07688 | ||||||
C | 1 | 6 | ZZ | AC | 314743-00-6 | 08664 | ||||||
1 | C | 1 | 5 | TX | D | 421418 | 14440 |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Navy
GIRDER
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 1 | 1 May 1997 | 5961000124215 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 0 | 21 Oct 1997 | 5961001759118 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 1 May 1997 | 5961003570377 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 0 | 21 Oct 1997 | 5961004012831 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 1 May 1997 | 5961007619379 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 21 Oct 1997 | 5961009056498 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 1 May 1997 | 5961009437765 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 1 May 1997 | 5961009449905 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 0 | 21 Oct 1997 | 5961012271946 | 1 May 1997 |
1 | TX | 0 | 3 | TX | 1 | 21 Oct 1997 | 5961013078444 | 1 May 1997 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | 3 | 9 | A | H | Z | W | 063025 | Z | 34525 | SEMICONDUCTORS-DEVICES-NOI-ETC |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | D | U | 1 | Z | EA | 0 | |
DF | SMS | D | U | 1 | N | EA | 0 | |
DM | SMS | D | U | 1 | Z | EA | 0 | |
DN | SMS | D | U | 0 | EA | 0 | ||
DS | SMS | D | U | 1 | N | EA | 0 | |
GP | SMS | D | U | 1 | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
No QUP
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | GX | 1 | 100 | 0.1 lbs | 0.003 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NB | X | D3 | E5 | ZZ | Q | Q | U | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
No requirement
A-A-3129, Type I, Grade B, anti-static open cell plastic cushioning; or PPP-C1797, Type II, polypropylene foam cushioning. Other electrostatic free cushioning is acceptable provided it meets the static decay rate test requirement of A-A-3129.
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
ASTM-D5118, fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ALBA | Electrode Internally-Electrically Connected To Case | COLLECTOR |
CTQX | Current Rating Per Characteristic | 4.00 AMPERES SOURCE CUTOFF CURRENT MAXIMUM AND 2.00 AMPERES SOURCE CUTOFF CURRENT MINIMUM |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
CTSG | Maximum Operating Temp Per Measurement Point | 200.0 DEG CELSIUS JUNCTION |
AKPV | Mounting Facility Quantity | 2 |
AXGY | Mounting Method | UNTHREADED HOLE |
CTMZ | Semiconductor Material | SILICON |
ABBH | Inclosure Material | METAL |
ALAS | Internal Configuration | JUNCTION CONTACT |
ALAZ | Joint Electronic Device Engineering Council/Jedec/Case Outline Designation | TO-66 |
CTRD | Power Rating Per Characteristic | 75.0 WATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR ABSOLUTE |
ABKW | Overall Height | 0.250 INCHES MINIMUM AND 0.340 INCHES MAXIMUM |
ABHP | Overall Length | 1.250 INCHES NOMINAL |
ABMK | Overall Width | 0.700 INCHES NOMINAL |
FEAT | Special Features | JUNCTION PATTERN ARRANGEMENT: NPN |
CTQN | Voltage Rating In Volts Per Characteristic | 90.0 MAXIMUM COLLECTOR TO BASE VOLTAGE, DC AND 60.0 MAXIMUM COLLECTOR-TO-EMITTER, RESISTANCE BETWEEN BASE AND EMITTER AND 55.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN AND 7.0 MAXIMUM EMITTER TO BASE VOLTAGE, DC |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD AND 1 CASE |