Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
16RIA40 | 3 - Design Control Reference | 9 - No Longer Used | INTERNATIONAL RECTIFIER CORPORATION | 81483 | ![]() |
16RC40A | 5 - Replaced / Discontinued | 9 - No Longer Used | INTERNATIONAL RECTIFIER CORPORATION | 81483 | ![]() |
18RC40 | E - Replace Reference Number | 8 - Replacement NSN | INTERNATIONAL RECTIFIER CORPORATION | 81483 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5961 | 004700192 | A110A0 | 33096 | X | 1 | A | N | B | U | 4 Feb 1970 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
A918 | A196 | 3 | H | Z | CD | CL | 1 Aug 2006 | |||||||||||||||||||||||
FXGX | FXTX | 3 | H | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 3 | H | Z | GH | GT | KE | HD | 1 Aug 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 9 | 3 | TX | D | 16RIA40 | 81483 | ![]() | ||||
4 | 5 | 9 | 3 | TX | B | 16RC40A | 81483 | ![]() | ||||
3 | E | 8 | 3 | TX | D | 18RC40 | 81483 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 9Z | 0 | 1 Jan 2009 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-K, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 72D | 3 | 9 | A | H | Z | W | 063025 | Z | 34525 | SEMICONDUCTORS-DEVICES-NOI-ETC |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.005 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | ZZ | Q | Q | 6 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTQX | Current Rating Per Characteristic | 34.00 AMPERES SOURCE CUTOFF CURRENT MAXIMUM OF STANDARD RANGE |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
CTSG | Maximum Operating Temp Per Measurement Point | 125.0 DEG CELSIUS JUNCTION |
AKPV | Mounting Facility Quantity | 1 |
AXGY | Mounting Method | THREADED STUD |
CQJX | Nominal Thread Size | 0.250 INCHES |
CTMZ | Semiconductor Material | SILICON |
ABBH | Inclosure Material | METAL |
CTRD | Power Rating Per Characteristic | 500.0 MILLIWATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR PRESET |
ABHP | Overall Length | 0.330 INCHES MINIMUM AND 0.505 INCHES MAXIMUM |
CCDG | Overall Width Across Flats | 0.544 INCHES MINIMUM AND 0.562 INCHES MAXIMUM |
CTQN | Voltage Rating In Volts Per Characteristic | 800.0 MAXIMUM BREAKOVER VOLTAGE, DC |
TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG AND 1 THREADED STUD |
THSD | Thread Series Designator | UNF |