Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2275220-0001 | 1 - Source of Control Reference | 2 - Production Item | HONEYWELL INTL INC | 55972 | ![]() |
2N3301 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 49956 | ![]() |
2N3301 | 3 - Design Control Reference | 2 - Production Item | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
2N3301 | 3 - Design Control Reference | 2 - Production Item | NATIONAL SEMICONDUCTOR CORP | 12040 | ![]() |
2N3301 | 3 - Design Control Reference | 2 - Production Item | FAIRCHILD SEMICONDUCTOR CORP | 07263 | ![]() |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5961 | 005313613 | A110A0 | 20588 | X | 4 | 4 | A | N | A | 0 | 14 Sep 1974 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist but technical data sufficient for preparation of a full descriptive method item identification could not be acquired after several follow-up actions during a 150-day suspense period. Includes such reasons as: Industry refuses to provide the technical data based on policy, restricted or proprietary rights, non-existence of technical data, etc. (This code cannot be used in submittals for National Item Identification Number (NIIN) assignment or reinstatement.)
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BN | N9ND | 0 | 0 | Z | KE | KE | 1 Aug 2006 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | 2 | 1 | KE | A | 2275220-0001 | 55972 | ![]() | ||||
3 | 3 | 2 | 5 | KE | D | 2N3301 | 04713 | ![]() | ||||
3 | 2 | 5 | KE | 2N3301 | 07263 | ![]() | ||||||
3 | 3 | 2 | 5 | KE | D | 2N3301 | 12040 | ![]() | ||||
3 | 3 | 2 | 5 | KE | D | 2N3301 | 49956 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | TX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | J | 658 | Z | 9 | A | H | Z | W | 063025 | Z | 34525 | SEMICONDUCTORS-DEVICES-NOI-ETC | 1 |
Naval ICP, Philadelphia, PA 19111
100.2
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | ZZ | Q | Q | 6 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ALBA | Electrode Internally-Electrically Connected To Case | COLLECTOR |
CBBL | Features Provided | HERMETICALLY SEALED CASE |
CTMZ | Semiconductor Material | SILICON |
ALAS | Internal Configuration | JUNCTION CONTACT |
ADAV | Overall Diameter | 0.209 INCHES MINIMUM AND 0.230 INCHES MAXIMUM |
ABKW | Overall Height | 0.170 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
FEAT | Special Features | JUNCTION PATTERN ARRANGEMENT: NPN |
TTQY | Terminal Type And Quantity | 3 UNINSULATED WIRE LEAD |