5961-00-724-2098

TRANSISTOR


5961-00-724-2098 (5961007242098, 007242098)
Part Numbers (9 listings): 2459394-2 | 2N2219 | TH1089 | 804899 | SL4183 | 2N2219A | TBA | TC10005 | N20017 |
Summary

FSG 59 / FSC 5961

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 21 Feb 1968

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

Replacement NSN:

5961-01-179-3470

Replacement Date: 10 Apr 1991

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-00-724-2098 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
2459394-23 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
2N22195 - Replaced / Discontinued1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
2N22195 - Replaced / Discontinued1 - Incomplete Part NumberRAYTHEON TECHNICAL SERVICES COMPANY  3B150    CAGE 3B150  
2459394-25 - Replaced / Discontinued2 - Production ItemRAYTHEON TECHNICAL SERVICES COMPANY  3B150    CAGE 3B150  
2N22195 - Replaced / Discontinued2 - Production ItemSPRAGUE ELECTRIC CO  56289      
TH10895 - Replaced / Discontinued2 - Production ItemSPRAGUE ELECTRIC CO  56289      
8048995 - Replaced / Discontinued2 - Production ItemNORTH ATLANTIC INDUSTRIES, INC.  0VGU1    CAGE 0VGU1  
2459394-25 - Replaced / Discontinued2 - Production ItemTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SL41835 - Replaced / Discontinued2 - Production ItemTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
2N22195 - Replaced / Discontinued2 - Production ItemADELCO ELEKTRONIK GMBH  C7191    CAGE C7191  
2N2219A5 - Replaced / Discontinued9 - No Longer UsedADELCO ELEKTRONIK GMBH  C7191    CAGE C7191  
TBA5 - Replaced / Discontinued9 - No Longer UsedFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N22195 - Replaced / Discontinued9 - No Longer UsedFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
2N22195 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  49956    CAGE 49956  
2459394-25 - Replaced / Discontinued9 - No Longer UsedRAYTHEON COMPANY  49956    CAGE 49956  
2N22195 - Replaced / Discontinued9 - No Longer UsedTELCOM SEMICONDUCTOR INC  15818    CAGE 15818  
TC100055 - Replaced / Discontinued9 - No Longer UsedTELCOM SEMICONDUCTOR INC  15818    CAGE 15818  
2459394-25 - Replaced / Discontinued9 - No Longer UsedFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
8048995 - Replaced / Discontinued9 - No Longer UsedNAI TECHNOLOGIES INC  07342    CAGE 07342  
2N22195 - Replaced / Discontinued9 - No Longer UsedTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
N200175 - Replaced / Discontinued9 - No Longer UsedNATIONAL SEMICONDUCTOR CORP  12040    CAGE 12040  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5961-00-724-2098 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961007242098A110A020588Y1ANBU021 Feb 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

007242098

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-00-724-2098

A110A0

Federal Item Identification Guide (FIIG_4065)

20588

Item Naming Code (INC_4080)

21 Feb 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

Y

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5961-00-724-2098 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZB011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
YB011 Apr 1991
YJ011 Apr 1991
ZT011 Apr 1991
ZU011 Apr 1991
ZR011 Jul 1997
YW011 Jan 1998
ZW011 Nov 1998
YA011 Aug 2010
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5961-00-724-2098 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321HDD2459394-2  10001  
515TX2N2219  3B150   CAGE/3B150
3515TXD2N2219  04713   CAGE/04713
3525TXD2459394-2  01295   CAGE/01295
15259ZDSL4183  01295   CAGE/01295
5259Z804899  0VGU1   CAGE/0VGU1
525TX2459394-2  3B150   CAGE/3B150
15259ZD2N2219  56289  
15259ZDTH1089  56289  
4526ZGA2N2219  C7191   CAGE/C7191
4596ZGB2N2219A  C7191   CAGE/C7191
3595TXB2459394-2  49956   CAGE/49956
3595TXB2N2219  49956   CAGE/49956
15959ZBN20017  12040   CAGE/12040
15959ZB2N2219  15818   CAGE/15818
15959ZBTC10005  15818   CAGE/15818
3595TXB2459394-2  04713   CAGE/04713
3595TXB2N2219  01295   CAGE/01295
5959Z2N2219  07263   CAGE/07263
5959ZTBA  07263   CAGE/07263
15959ZB804899  07342   CAGE/07342
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

HD

Reference Number Action Activity Code (RNAAC_2900)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-00-724-2098 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX010 Apr 1991 5961011793470 15 Sep 1978
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Apr 1991

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5961-01-179-3470

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

15 Sep 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-00-724-2098 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
HD72D39AHZW063025Z34525SEMICONDUCTORS-DEVICES-NOI-ETC
Code Definitions

HD

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063025

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34525

Uniform Freight Classification (UFC_CD_MODF_3040)

SEMICONDUCTORS-DEVICES-NOI-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5961-00-724-2098 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EVU5EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

5

Quantity Unit Pack (QUP_6106)


5

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5961-00-724-2098 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PXXX
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XR6M
Code Definitions

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

XXX

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

R

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 2.

6

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-00-724-2098 Submit RFQ
MRCDecoded RequirementClear Text Reply
CRTLCriticality Code JustificationFEAT
CTQXCurrent Rating Per Characteristic800.00 MILLIAMPERES SOURCE CUTOFF CURRENT MAXIMUM
CBBLFeatures ProvidedHERMETICALLY SEALED CASE
CTSGMaximum Operating Temp Per Measurement Point200.0 DEG CELSIUS JUNCTION
AXGYMounting MethodTERMINAL
CTMZSemiconductor MaterialSILICON
ABBHInclosure MaterialMETAL
ALASInternal ConfigurationJUNCTION CONTACT
CTRDPower Rating Per Characteristic800.0 MILLIWATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR MINIMUM
ADAVOverall Diameter0.335 INCHES MAXIMUM
ABHPOverall Length0.250 INCHES NOMINAL
FEATSpecial FeaturesSTATIC ELECTRICITY SENSITIVE; JUNCTION PATTERN ARRANGEMENT: NPN
CTQNVoltage Rating In Volts Per Characteristic60.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN AND 30.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN AND 5.0 MAXIMUM BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN
AYQSTerminal Circle Diameter0.335 INCHES NOMINAL
ABJTTerminal Length1.500 INCHES MINIMUM
TTQYTerminal Type And Quantity3 UNINSULATED WIRE LEAD


Back to Top
Back to Top