Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
JAN1N938B | 2 - Definitive Specification or Standard Document | 2 - Production Item | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-PRF-19500/156 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
200449-003 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | BAE SYSTEMS INFORMATION AND | 81413 | ![]() |
6099316 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 03640 | ![]() |
1N938 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
VBE408-40 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | THALES NEDERLAND B.V. | H0203 | ![]() |
352250017431 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | THALES NEDERLAND B.V. | H0203 | ![]() |
28471-11531 | 5 - Replaced / Discontinued | 2 - Production Item | SELEX ES LTD | K0662 | ![]() |
AE4565630 | 5 - Replaced / Discontinued | 2 - Production Item | ROHDE & SCHWARZ GMBH & CO. KG | D0894 | ![]() |
5961008920889 | 5 - Replaced / Discontinued | 9 - No Longer Used | E.C.A ETABLISSEMENT | SCY13 | ![]() |
JAN1N938BA | 5 - Replaced / Discontinued | 9 - No Longer Used | ADELCO ELEKTRONIK GMBH | C7191 | ![]() |
JAN1N938A | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
MIL-S-19500/156 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
1N938B | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
0N014727 | C - Advisory Reference | 1 - Incomplete Part Number | NATIONAL SECURITY AGENCY | 98230 | ![]() |
418299-3 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 96214 | ![]() |
844762 | C - Advisory Reference | 1 - Incomplete Part Number | L-3 COMMUNICATIONS CORPORATION | 06141 | ![]() |
S106-0181 | C - Advisory Reference | 1 - Incomplete Part Number | ENGINEERED ELECTRIC COMPANY | 93742 | ![]() |
10394198-111 | C - Advisory Reference | 1 - Incomplete Part Number | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
1N938A | C - Advisory Reference | 1 - Incomplete Part Number | ELECTRONIC INDUSTRIES ASSOCIATION | 80131 | ![]() |
4178600-226 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 05869 | ![]() |
333967-102 | C - Advisory Reference | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 56232 | ![]() |
1N936 | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
1N936 | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5961 | 008920889 | A110A0 | 20589 | X | 1 | A | N | A | A | 0 | 1 Jan 1962 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G170 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G280 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
G860 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YD01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZK01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YW01 | 1 Jul 1993 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
WP01 | 1 Jan 2006 | |||||||||||||||||||||||||||||
YA01 | 1 Nov 2008 | |||||||||||||||||||||||||||||
YP01 | 1 Nov 2008 | |||||||||||||||||||||||||||||
YS01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
YK01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 4 | ZZ | MIL-PRF-19500/156 | 81349 | ![]() | ||||||
3 | 5 | 1 | 5 | TX | D | 200449-003 | 81413 | ![]() | ||||
5 | 1 | 5 | TX | 1N938 | 04713 | ![]() | ||||||
3 | 5 | 1 | 5 | TX | D | 6099316 | 03640 | ![]() | ||||
3 | 5 | 1 | 5 | TX | D | 352250017431 | H0203 | ![]() | ||||
3 | 5 | 1 | 5 | TX | D | VBE408-40 | H0203 | ![]() | ||||
3 | 5 | 2 | 3 | ZG | D | 28471-11531 | K0662 | ![]() | ||||
4 | 5 | 2 | 3 | ZG | D | AE4565630 | D0894 | ![]() | ||||
4 | 5 | 9 | 6 | ZG | B | JAN1N938BA | C7191 | ![]() | ||||
4 | 5 | 9 | 3 | TX | B | MIL-S-19500/156 | 81349 | ![]() | ||||
3 | 5 | 9 | 3 | KE | B | 1N938B | 81349 | ![]() | ||||
4 | 5 | 9 | 3 | TX | B | JAN1N938A | 81349 | ![]() | ||||
4 | 5 | 9 | 9 | YP | B | 5961008920889 | SCY13 | ![]() | ||||
4 | C | 1 | 5 | TX | D | AO | 1N936 | 04713 | ![]() | |||
3 | C | 1 | 5 | TX | D | 4178600-226 | 05869 | ![]() | ||||
C | 1 | 5 | 48 | AH | 844762 | 06141 | ![]() | |||||
C | 1 | 5 | TX | AF | 10394198-111 | 18876 | ![]() | |||||
4 | C | 1 | 5 | TX | D | 333967-102 | 56232 | ![]() | ||||
4 | C | 1 | 9 | TU | B | 1N938A | 80131 | ![]() | ||||
1 | C | 1 | 5 | 48 | A | S106-0181 | 93742 | ![]() | ||||
1 | C | 1 | 5 | 48 | A | 418299-3 | 96214 | ![]() | ||||
C | 1 | 5 | TX | AF | 0N014727 | 98230 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
USA
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
Germany
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Naval ICP, Philadelphia, PA 19111
The reference number is of the type for which an indication of document availability is not required.
Morocco
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Army / Defense Logistics Agency
Federal Aviation Administration, Oklahoma City, OK 73125
Federal Aviation Administration
Defense Logistics Agency
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | TX | 0 | 1 | TX | 0 | 8 Dec 1997 | 5961012996352 | 5 Dec 1997 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | W | 063025 | Z | 34525 | SEMICONDUCTORS-DEVICES-NOI-ETC |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Defense Logistics Agency
Department of the Army
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | XXX | 0.1 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | 00 | Q | Q | 6 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CTQX | Current Rating Per Characteristic | 50.00 MILLIAMPERES REPETITIVE PEAK FORWARD CURRENT NOMINAL |
AFZC | Function For Which Designed | ZENER DIODE |
CTSG | Maximum Operating Temp Per Measurement Point | 175.0 DEG CELSIUS AMBIENT AIR |
AXGY | Mounting Method | TERMINAL |
ABBH | Inclosure Material | GLASS |
CTRD | Power Rating Per Characteristic | 500.0 MILLIWATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR PRESET |
CTMZ | Semiconductor Material | SILICON |
ADAV | Overall Diameter | 0.060 INCHES MINIMUM AND 0.107 INCHES MAXIMUM |
ABHP | Overall Length | 0.120 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
CTQN | Voltage Rating In Volts Per Characteristic | 9.0 NOMINAL NOMINAL REGULATOR VOLTAGE |
CTQS | Voltage Tolerance In Percent | -5.0/+5.0 |
ZZZK | Specification/Standard Data | 81349-MIL-S-19500/156 GOVERNMENT SPECIFICATION |
ABJT | Terminal Length | 1.000 INCHES MINIMUM AND 1.500 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 2 UNINSULATED WIRE LEAD |
TEST | Test Data Document | 81349-MIL-S-19500 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |