Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
TIP30B | 3 - Design Control Reference | 9 - No Longer Used | TEXAS INSTRUMENTS INCORPORATED | 01295 | ![]() |
TIP30B | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
4902-03-0301 | 5 - Replaced / Discontinued | 9 - No Longer Used | WAVETEK U S INC | 23338 | ![]() |
T1P30B | 5 - Replaced / Discontinued | 9 - No Longer Used | TEXAS INSTRUMENTS INCORPORATED | 01295 | ![]() |
TIP30B | E - Replace Reference Number | 8 - Replacement NSN | NATIONAL SEMICONDUCTOR CORPORATION | 27014 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5961 | 010360481 | A110A0 | 20588 | X | K | A | N | B | U | 19 Feb 1977 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
G860 | 0 | 0 | C | 1 Dec 1993 | ||||||||||||||||||||||||||
YB01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
A918 | A196 | 5 | L | Z | CD | CL | 1 Aug 2006 | |||||||||||||||||||||||
FXGX | FXTX | 5 | L | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
MC49 | MC13 | 5 | L | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 5 | L | Z | GH | GT | KE | HS | HD | 1 Aug 2006 | ||||||||||||||||||||
S911 | S007 | 5 | L | Z | XN | 1 Aug 2006 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000
Naval ICP, Philadelphia, PA 19111
Navy ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 9 | 5 | 48 | A | TIP30B | 01295 | ![]() | ||||
5 | 9 | E | TX | TIP30B | 04713 | ![]() | ||||||
4 | 5 | 9 | 5 | TX | B | 4902-03-0301 | 23338 | ![]() | ||||
4 | 5 | 9 | 5 | TX | D | T1P30B | 01295 | ![]() | ||||
E | 8 | E | TX | TIP30B | 27014 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Federal Aviation Administration, Oklahoma City, OK 73125
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 1 | 10 Apr 1991 | 5961004320519 | 10 Apr 1991 |
1 | TX | 0 | 3 | TX | 1 | 23 Oct 1997 | 5961004733162 | 10 Apr 1991 |
1 | TX | 0 | 3 | TX | 1 | 23 Oct 1997 | 5961011009547 | 10 Apr 1991 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
48 | 72D | 3 | 9 | A | H | Z | W | 063025 | Z | 34525 | SEMICONDUCTORS-DEVICES-NOI-ETC |
Federal Aviation Administration, Oklahoma City, OK 73125
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | Z | U | 1 | A | EA | 0 | |
DF | SMS | Z | U | 1 | N | EA | 0 | |
DM | SMS | Z | U | 1 | Z | EA | 0 | |
DN | SMS | D | U | 0 | EA | 0 | ||
DS | SMS | Z | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
No QUP
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | ZZ | XXX | 0.1 lbs | 0.002 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
X | ZZ | Q | Q | U | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ALBA | Electrode Internally-Electrically Connected To Case | COLLECTOR |
CTQX | Current Rating Per Characteristic | 3.00 AMPERES SOURCE CUTOFF CURRENT MAXIMUM |
CTSG | Maximum Operating Temp Per Measurement Point | 165.0 DEG CELSIUS JUNCTION |
AKPV | Mounting Facility Quantity | 1 |
AXGY | Mounting Method | UNTHREADED HOLE |
CTMZ | Semiconductor Material | SILICON |
ABBH | Inclosure Material | PLASTIC |
ALAS | Internal Configuration | JUNCTION CONTACT |
CTRD | Power Rating Per Characteristic | 2.0 WATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR ABSOLUTE |
ABKW | Overall Height | 0.190 INCHES MAXIMUM |
ABHP | Overall Length | 0.375 INCHES MAXIMUM |
ABMK | Overall Width | 0.420 INCHES MAXIMUM |
FEAT | Special Features | JUNCTION PATTERN ARRANGEMENT: PNP |
CTQN | Voltage Rating In Volts Per Characteristic | 80.0 NOMINAL COLLECTOR TO BASE VOLTAGE, DC |
TTQY | Terminal Type And Quantity | 3 UNINSULATED WIRE LEAD |