5961-01-036-1274

SEMICONDUCTOR DEVICE,DIODE


5961-01-036-1274 (5961010361274, 010361274)
Part Numbers (2 listings): 932354-1 | 1N4150-1 |
Summary

FSG 59 / FSC 5961

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 23 Feb 1977

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.001 cu ft

Replacement NSN:

5961-01-070-7446

Replacement Date: 22 Mar 1993

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-01-036-1274 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
932354-13 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
1N4150-15 - Replaced / Discontinued1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
1N4150-15 - Replaced / Discontinued1 - Incomplete Part NumberMICRO USPD INC  12969      
1N4150-15 - Replaced / Discontinued1 - Incomplete Part NumberGENERAL ELECTRIC CO  03508    CAGE 03508  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5961-01-036-1274 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961010361274A110A020589X1ANBU23 Feb 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

010361274

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-01-036-1274

A110A0

Federal Item Identification Guide (FIIG_4065)

20589

Item Naming Code (INC_4080)

23 Feb 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5961-01-036-1274 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZW011 Dec 1995
ZR011 Jul 1997
YA011 Jan 2011
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5961-01-036-1274 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
132ATXA932354-1  06481   CAGE/06481
516TX1N4150-1  12969  
516TX1N4150-1  01295   CAGE/01295
516TX1N4150-1  03508   CAGE/03508
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-01-036-1274 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX11TX022 Mar 1993 5961010707446 22 Mar 1993
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Mar 1993

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5961-01-070-7446

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

22 Mar 1993

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-01-036-1274 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE65839AHZW063025Z34525SEMICONDUCTORS-DEVICES-NOI-ETC
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063025

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34525

Uniform Freight Classification (UFC_CD_MODF_3040)

SEMICONDUCTORS-DEVICES-NOI-ETC

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5961-01-036-1274 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU1EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5961-01-036-1274 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
P1AAA0.1 lbs0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD339EQU
Code Definitions

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-01-036-1274 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTRGCapacitance Rating In Picofarads2.5 MAXIMUM
CTQXCurrent Rating Per Characteristic4.00 AMPERES SOURCE CUTOFF CURRENT PRESET
CBBLFeatures ProvidedBURN IN
AFZCFunction For Which DesignedGENERAL PURPOSE
CTSGMaximum Operating Temp Per Measurement Point175.0 DEG CELSIUS AMBIENT AIR
AXGYMounting MethodTERMINAL
ABBHInclosure MaterialGLASS
CTRDPower Rating Per Characteristic475.0 MILLIWATTS LARGE-SIGNAL INPUT POWER, COMMON-EMITTER ABSOLUTE
CTMZSemiconductor MaterialSILICON
ADAVOverall Diameter0.075 INCHES MAXIMUM
ABHPOverall Length0.180 INCHES MAXIMUM
CTQNVoltage Rating In Volts Per Characteristic60.0 MAXIMUM REVERSE VOLTAGE, INSTANTANEOUS
ABJTTerminal Length1.000 INCHES MINIMUM
TTQYTerminal Type And Quantity2 UNINSULATED WIRE LEAD
TESTTest Data Document06481-932354 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Back to Top
Back to Top