5961-01-136-7013

TRANSISTOR


5961-01-136-7013 (5961011367013, 011367013)
Part Numbers (2 listings): GES5307 | 2209 |
Summary

FSG 59 / FSC 5961

DEMIL: Q

DEMIL INT:

HMIC: N

Date Created: 13 Aug 1982

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5961-01-136-7013 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
GES53073 - Design Control Reference9 - No Longer UsedGENERAL ELECTRIC CO  03508    CAGE 03508  
22095 - Replaced / Discontinued9 - No Longer UsedEXTEL CORP  52247    CAGE 52247  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5961-01-136-7013 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595961011367013A110A020588X46QNAU13 Aug 1982
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5961

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Semiconductor Devices and Associated Hardware

011367013

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5961-01-136-7013

A110A0

Federal Item Identification Guide (FIIG_4065)

20588

Item Naming Code (INC_4080)

13 Aug 1982

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5961-01-136-7013 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YK011 Jan 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5961-01-136-7013 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43949ZDGES5307  03508   CAGE/03508
45969ZB2209  52247   CAGE/52247
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5961-01-136-7013 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597613 Aug 1982
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

13 Aug 1982

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5961-01-136-7013 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
YK
Code Definitions

YK

Originating Activity Code (ORIG_ACTY_CD_4210)


Kuwait

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5961-01-136-7013 Submit RFQ
MRCDecoded RequirementClear Text Reply
CTQXCurrent Rating Per Characteristic300.00 MILLIAMPERES SOURCE CUTOFF CURRENT MAXIMUM AND 50.00 MILLIAMPERES SOURCE CUTOFF CURRENT MINIMUM
CTSGMaximum Operating Temp Per Measurement Point125.0 DEG CELSIUS AMBIENT AIR
AXGYMounting MethodTERMINAL
CTMZSemiconductor MaterialSILICON
ALASInternal ConfigurationJUNCTION CONTACT-DARLINGTON CONNECTED
CTRDPower Rating Per Characteristic900.0 MILLIWATTS SMALL-SIGNAL INPUT POWER, COMMON-COLLECTOR PRESET
ABKWOverall Height0.175 INCHES MINIMUM AND 0.205 INCHES MAXIMUM
ABHPOverall Length0.170 INCHES MINIMUM AND 0.210 INCHES MAXIMUM
ABMKOverall Width0.125 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
FEATSpecial FeaturesJUNCTION PATTERN ARRANGEMENT: NPN
CTQNVoltage Rating In Volts Per Characteristic40.0 MAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN AND 40.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE, DC AND 12.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN
AYQSTerminal Circle Diameter0.095 INCHES MINIMUM AND 0.105 INCHES MAXIMUM
ABJTTerminal Length0.500 INCHES MINIMUM
TTQYTerminal Type And Quantity3 UNINSULATED WIRE LEAD


Back to Top
Back to Top