| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| MR2006S | 3 - Design Control Reference | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5961 | 011747980 | A110A0 | 20589 | X | 4 | 9 | A | N | A | 22 Mar 1984 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 9 | 6 | XG | MR2006S | 04713 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USCG Engineering Logistics Center, Baltimore, MD 21226-5000
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 2 | TX | 0 | 27 Mar 1993 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| XG |
USCG Engineering Logistics Center, Baltimore, MD 21226-5000
No Variation. NMFC and UFCC Match.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| ALBA | Electrode Internally-Electrically Connected To Case | CATHODE |
| CTSG | Maximum Operating Temp Per Measurement Point | 175.0 DEG CELSIUS JUNCTION |
| AKPV | Mounting Facility Quantity | 1 |
| AXGY | Mounting Method | THREADED STUD |
| CQJX | Nominal Thread Size | 0.190 INCHES |
| ABBH | Inclosure Material | CERAMIC AND METAL |
| ALAZ | Joint Electronic Device Engineering Council/Jedec/Case Outline Designation | DO-4 |
| CTMZ | Semiconductor Material | SILICON |
| ABHP | Overall Length | 1.253 INCHES MAXIMUM |
| ABMK | Overall Width | 0.500 INCHES MAXIMUM |
| CTQN | Voltage Rating In Volts Per Characteristic | 600.0 MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE AND 720.0 MAXIMUM NONREPETITIVE PEAK REVERSE VOLTAGE |
| TTQY | Terminal Type And Quantity | 1 THREADED STUD AND 1 WIRE HOOK |
| THSD | Thread Series Designator | UNF |
| CMLP | Thread Quantity Per Inch | 32 |