5962-00-117-6075

MICROCIRCUIT,DIGITAL


5962-00-117-6075 (5962001176075, 001176075)
Part Numbers (2 listings): 507869-2 | SN5473-1 |
Summary

FSG 59 / FSC 5962

DEMIL: Q

DEMIL INT:

HMIC: N

Date Created: 4 Oct 1968

Replacement NSN:

5962-01-283-7123

Replacement Date: 6 Sep 1994

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-00-117-6075 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
507869-21 - Source of Control Reference2 - Production ItemRAYTHEON COMPANY  96214    CAGE 96214  
SN5473-13 - Design Control Reference2 - Production ItemTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
Code Definitions

1 - Source of Control Reference

Reference Number Category Code (DRN_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5962-00-117-6075 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962001176075A458A031779X1QNBG4 Oct 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

001176075

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-00-117-6075

A458A0

Federal Item Identification Guide (FIIG_4065)

31779

Item Naming Code (INC_4080)

4 Oct 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

G

Precious Metals Indicator Code (PMIC_0802)


Item contains gold.


FLIS - SEG B - MOE RULE DATA | NSN 5962-00-117-6075 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZP011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5962-00-117-6075 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1121TXD507869-2  96214   CAGE/96214
1323TXDSN5473-1  01295   CAGE/01295
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

1

Reference Number Category Code (RNCC_2910)


Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5962-00-117-6075 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX1BTX06 Sep 1994 5962012837123 6 Sep 1994
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

1

NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

B

Replaced / Replacement Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Sep 1994

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5962-01-283-7123

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

6 Sep 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5962-00-117-6075 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SG65835AHYW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SG

Originating Activity Code (ORIG_ACTY_CD_4210)


403 SCMS/GUED, 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

5

Special Handling Code (SP_HDLG_CD_9240)


Protected (Pilferable)

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Y

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-00-117-6075 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.035 INCHES MINIMUM AND 0.050 INCHES MAXIMUM
ADAQBody Length0.250 INCHES MINIMUM AND 0.260 INCHES MAXIMUM
ADATBody Width0.145 INCHES MAXIMUM
CSSLDesign Function And Quantity2 FLIP-FLOP, J-K, MASTER SLAVE
CBBLFeatures ProvidedPOSITIVE OUTPUTS AND W/ENABLE AND W/CLEAR AND HERMETICALLY SEALED AND MONOLITHIC
AEHXMaximum Power Dissipation Rating100.0 MILLIWATTS
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQWXOutput Logic FormTRANSISTOR-TRANSISTOR LOGIC
CQSZInclosure ConfigurationFLAT PACK
CQSJInclosure MaterialCERAMIC AND GLASS
CQZPInput Circuit PatternDUAL 4 INPUT
PMLCPrecious Material And LocationTERMINAL SURFACE GOLD
PRMTPrecious MaterialGOLD
FEATSpecial FeaturesFORMED LEADS
CZENVoltage Rating And Type Per Characteristic-1.5 VOLTS MINIMUM POWER SOURCE AND 5.5 VOLTS MAXIMUM POWER SOURCE
AFJQStorage Temp Range-65.0/+150.0 DEG CELSIUS
TTQYTerminal Type And Quantity14 FLAT LEADS
CWSGTerminal Surface TreatmentGOLD
TESTTest Data Document96214-507869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
CZEQTime Rating Per Chacteristic50.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT AND 50.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, HIGH TO LOW LEVEL OUTPUT


Back to Top
Back to Top