5962-00-172-8268

MICROCIRCUIT,DIGITAL


5962-00-172-8268 (5962001728268, 001728268)
Part Numbers (9 listings): S8288F/883C | S8288F | S8288F/883B | 985115-288 | N8288F | N8288N | DM7288J | S8288FA | SL8288C1 |
Summary

FSG 59 / FSC 5962

DEMIL: Q

DEMIL INT: 3

HMIC: N

Date Created: 26 Nov 1971

Unit Weight: 0.1 lbs

Unit Size: None

Unit Pack Cube: 0.001 cu ft

Replacement NSN:

5962-00-410-8359

Replacement Date: 28 Sep 1980

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-00-172-8268 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
S8288F/883C3 - Design Control Reference9 - No Longer UsedPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
S8288F5 - Replaced / Discontinued9 - No Longer UsedPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
S8288F/883B5 - Replaced / Discontinued9 - No Longer UsedPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
985115-2885 - Replaced / Discontinued9 - No Longer UsedTITAN CORP THE  16224      
N8288FC - Advisory Reference1 - Incomplete Part NumberPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
N8288NC - Advisory Reference1 - Incomplete Part NumberPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
N8288NC - Advisory Reference1 - Incomplete Part NumberPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
985115-288C - Advisory Reference1 - Incomplete Part NumberL-3 SERVICES, INC.  63702      
985115-288C - Advisory Reference1 - Incomplete Part NumberL-3 SERVICES, INC.  63702      
DM7288JE - Replace Reference Number8 - Replacement NSNNATIONAL SEMICONDUCTOR CORPORATION  27014    CAGE 27014  
S8288FAE - Replace Reference Number8 - Replacement NSNLANSDALE SEMICONDUCTOR, INC.  58625      
SL8288C1E - Replace Reference Number8 - Replacement NSNLANSDALE SEMICONDUCTOR, INC.  58625      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

E - Replace Reference Number

Reference Number Category Code (DRN_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

8 - Replacement NSN

Reference Number Variation Code (DRN_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.


FLIS - SEG A - IDENTIFICATION | NSN 5962-00-172-8268 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962001728268A458A031779X43QNBA026 Nov 1971
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

001728268

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-00-172-8268

A458A0

Federal Item Identification Guide (FIIG_4065)

31779

Item Naming Code (INC_4080)

26 Nov 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5962-00-172-8268 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZA011 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZH011 Apr 1991
ZW011 Nov 1998
YA011 Dec 1999
WP011 Nov 2004
WB011 Feb 2005
C911C0073C1 Aug 2006
FXGXFXTX3CZSX1 Aug 2006
N9BNN9ND3CZKEGTKEJBHD1 Aug 2006
S911S0073CZXN1 Aug 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

XN

Item Management Coding Activity (IMC_ACTY_2748)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

JBCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5962-00-172-8268 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
395TXS8288F/883C  18324   CAGE/18324
595TXB985115-288  16224  
4593TXBS8288F  18324   CAGE/18324
4593TXBS8288F/883B  18324   CAGE/18324
C13ZZACN8288F  18324   CAGE/18324
C16TUAWN8288N  18324   CAGE/18324
C15ZZ9F985115-288  63702  
E8ETXDM7288J  27014   CAGE/27014
E85TXS8288FA  58625  
E85ZZSL8288C1  58625  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

9F

Service / Agency Designator Code (SADC_4672)


CAGE Status Change

E

Reference Number Category Code (RNCC_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

8

Reference Number Variation Code (RNVC_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5962-00-172-8268 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
1TX03TX128 Sep 1980 5962004108359 28 Feb 1990
Code Definitions

1

Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

28 Sep 1980

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5962-00-410-8359

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

28 Feb 1990

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5962-00-172-8268 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TXP72D39AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

P

Less Than Carload (LCL_CD_2760)


77.5

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5962-00-172-8268 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSVU1ZEA0
DFSMSDU1NEA0
DNSMSDU1EA0
DSSMSDU1NEA0
GPSMSDU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5962-00-172-8268 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPGX1AAA0.1 lbs0.001 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD3ZZQQUM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.1 lbs

Unit Pack Weight (UP_WT_5153)

0.001 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-00-172-8268 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.140 INCHES MINIMUM AND 0.180 INCHES MAXIMUM
ADAQBody Length0.660 INCHES MINIMUM AND 0.785 INCHES MAXIMUM
ADATBody Width0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM
CTFTCase Outline Source And DesignatorT0-116 JOINT ELECTRON DEVICE ENGINEERING COUNCIL
CBBLFeatures ProvidedASYNCHRONOUS AND HERMETICALLY SEALED AND MONOLITHIC AND POSITIVE OUTPUTS AND PRESETTABLE AND RESETTABLE AND W/STROBE AND NEGATIVE EDGE TRIGGERED
AEHXMaximum Power Dissipation Rating236.0 MILLIWATTS
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQWXOutput Logic FormTRANSISTOR-TRANSISTOR LOGIC
CQSZInclosure ConfigurationDUAL-IN-LINE
CQSJInclosure MaterialCERAMIC AND GLASS
CQZPInput Circuit Pattern8 INPUT
CZENVoltage Rating And Type Per Characteristic-1.5 VOLTS MINIMUM POWER SOURCE AND 5.5 VOLTS MAXIMUM POWER SOURCE
AFJQStorage Temp Range-65.0/+200.0 DEG CELSIUS
TTQYTerminal Type And Quantity14 PRINTED CIRCUIT
CWSGTerminal Surface TreatmentSOLDER
CZEQTime Rating Per Chacteristic40.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT AND 35.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, HIGH TO LOW LEVEL OUTPUT


Back to Top