5962-00-369-7831

MICROCIRCUIT,DIGITAL


5962-00-369-7831 (5962003697831, 003697831)
Part Numbers (77 listings): M38510/00502BCA | MIL-M-38510/5 | W5083098CM | 28578-01051 | DM7451N | M38510/00502BCB | M38510/00502BCX | M38510/00502CCB | SNC5451J | MIL-M-38510 | M38510-05025CD | 10053-0 | 5451DM | P161-5451 | SN5451J-10 | 7451DCQB | P106074-51M | 581R500H95 | 128C821H10 | 9S6033-11 | 058-002193 | 122-7451 | 025707F | 3214006-001-536 | SD19796A | SN7451AN | SN7451N-00 | SN7451J00 | 7451 | 5451 | 5451J | WC5451 | SN23904 | SN23904J | SNM5451J | SN6081N | SN5451S17 | NC5335 | 37654822-001 | 5509415G29 | 3-12522-213-38 | 2885040-5B | 51NW9615A44 | SC5086PK | 351-7694-012 | 373715-1 | 389332/1 | 310095P1 | 7903788-02 | JANM38510-00502BCX | JM38510-00502BCB | 116979-002 | 5451D | 351-7694-010 | SN5451J | 538904-2 | 99000014-001 | 4005013-402 | DM7451J | 0310095P001 | 7903788-01 | 2131619-1 | MC7451LB4 | MC7451P | MC5451L | RC5451F | N7451A | N7451N | S5451A | 7451J883C | 100A330-2 | SN5451AJ | SN5451J00 | MPD20709AJ | 7451DCQC | 3520045-1 | US7451A |
Summary

FSG 59 / FSC 5962

DEMIL: Q

DEMIL INT: 3

HMIC: N

Date Created: 3 Mar 1974

Unit Weight: 0.2 lbs

Unit Size: None

Unit Pack Cube: 0.017 cu ft

Replacement NSN:

5962-00-009-2240

Replacement Date: 5 Sep 1974

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-00-369-7831 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M38510/00502BCA2 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-M-38510/54 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
W5083098CM5 - Replaced / Discontinued2 - Production ItemRHEINMETALL AIR DEFENCE AG  S3092    CAGE S3092  
28578-010515 - Replaced / Discontinued2 - Production ItemSELEX ES LTD  K0662    CAGE K0662  
W5083098CM5 - Replaced / Discontinued9 - No Longer UsedOERLIKON-BUEHRLE AG  S3118    CAGE S3118  
DM7451N5 - Replaced / Discontinued9 - No Longer UsedNATIONAL SEMICONDUCTOR CORPORATION  27014    CAGE 27014  
M38510/00502BCB5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M38510/00502BCX5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M38510/00502CCBC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
SNC5451JC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-M-38510C - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
M38510-05025CDC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
10053-0C - Advisory Reference1 - Incomplete Part NumberSHUGART ASSOCIATES  56481      
5451DMC - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
P161-5451C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  95542    CAGE 95542  
P161-5451C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  95542    CAGE 95542  
SN5451J-10C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
7451DCQBC - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
P106074-51MC - Advisory Reference1 - Incomplete Part NumberGIORDANO ASSOCIATES INC  34309      
P106074-51MC - Advisory Reference1 - Incomplete Part NumberGIORDANO ASSOCIATES INC  34309      
581R500H95C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
581R500H95C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
128C821H10C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  97942    CAGE 97942  
9S6033-11C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  46859    CAGE 46859  
058-002193C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  26916    CAGE 26916  
122-7451C - Advisory Reference1 - Incomplete Part NumberWAVETEK  50621      
122-7451C - Advisory Reference1 - Incomplete Part NumberWAVETEK  50621      
025707FC - Advisory Reference1 - Incomplete Part NumberSYSTRON-DONNER CORP  52542    CAGE 52542  
025707FC - Advisory Reference1 - Incomplete Part NumberSYSTRON-DONNER CORP  52542    CAGE 52542  
3214006-001-536C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  99696    CAGE 99696  
3214006-001-536C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  99696    CAGE 99696  
SD19796AC - Advisory Reference1 - Incomplete Part NumberNATIONAL SEMICONDUCTOR CORPORATION  27014    CAGE 27014  
SN7451ANC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN7451ANC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN7451N-00C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN7451N-00C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN7451J00C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
7451C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
7451C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
5451C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
5451C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
5451JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
5451JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
WC5451C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN23904C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN23904JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN23904JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SNM5451JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN6081NC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN5451S17C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
NC5335C - Advisory Reference1 - Incomplete Part NumberITT SEMICONDUCTORS DIV  14433    CAGE 14433  
37654822-001C - Advisory Reference1 - Incomplete Part NumberTRIUMPH AEROSTRUCTURES, LLC  80378    CAGE 80378  
5509415G29C - Advisory Reference1 - Incomplete Part NumberITT FEDERAL LABORATORIES DIV OF  90348      
3-12522-213-38C - Advisory Reference1 - Incomplete Part NumberPERIPHERAL DYNAMICS INC  55209      
2885040-5BC - Advisory Reference1 - Incomplete Part NumberNAVAL SEA SYSTEMS COMMAND  53711    CAGE 53711  
51NW9615A44C - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
SC5086PKC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
SC5086PKC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
351-7694-012C - Advisory Reference1 - Incomplete Part NumberCUBIC DEFENSE APPLICATIONS, INC.  94987    CAGE 94987  
373715-1C - Advisory Reference1 - Incomplete Part NumberEDO CORPORATION  00752    CAGE 00752  
389332/1C - Advisory Reference1 - Incomplete Part NumberEDO CORPORATION  00752    CAGE 00752  
389332/1C - Advisory Reference1 - Incomplete Part NumberEDO CORPORATION  00752    CAGE 00752  
310095P1C - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS INFORMATION AND  94117    CAGE 94117  
7903788-02C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  90536    CAGE 90536  
JANM38510-00502BCXC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
JM38510-00502BCBC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
116979-002C - Advisory Reference1 - Incomplete Part NumberHARRIS CORPORATION  91417    CAGE 91417  
5451DC - Advisory Reference1 - Incomplete Part NumberROCKWELL COLLINS, INC.  13499    CAGE 13499  
351-7694-010C - Advisory Reference1 - Incomplete Part NumberROCKWELL COLLINS, INC.  13499    CAGE 13499  
351-7694-010C - Advisory Reference1 - Incomplete Part NumberROCKWELL COLLINS, INC.  13499    CAGE 13499  
SN5451JC - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  96214    CAGE 96214  
538904-2C - Advisory Reference1 - Incomplete Part NumberRAYTHEON COMPANY  96214    CAGE 96214  
99000014-001C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  94580    CAGE 94580  
4005013-402C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  07187    CAGE 07187  
4005013-402C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  07187    CAGE 07187  
DM7451JC - Advisory Reference1 - Incomplete Part NumberNATIONAL SEMICONDUCTOR CORP  12040    CAGE 12040  
DM7451JC - Advisory Reference1 - Incomplete Part NumberNATIONAL SEMICONDUCTOR CORP  12040    CAGE 12040  
0310095P001E - Replace Reference Number8 - Replacement NSNBAE SYSTEMS INFORMATION AND  94117    CAGE 94117  
7903788-01E - Replace Reference Number8 - Replacement NSNLOCKHEED MARTIN CORPORATION  90536    CAGE 90536  
2131619-1E - Replace Reference Number8 - Replacement NSNHONEYWELL INTL INC DEFENSE AVIONICS  19315    CAGE 19315  
MC7451LB4E - Replace Reference Number8 - Replacement NSNFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
MC7451PE - Replace Reference Number8 - Replacement NSNFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
MC5451LE - Replace Reference Number8 - Replacement NSNFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
RC5451FE - Replace Reference Number8 - Replacement NSNPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
N7451AE - Replace Reference Number8 - Replacement NSNPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
N7451NE - Replace Reference Number8 - Replacement NSNPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
S5451AE - Replace Reference Number8 - Replacement NSNPHILIPS SEMICONDUCTORS INC  18324    CAGE 18324  
7451J883CE - Replace Reference Number8 - Replacement NSNITT SEMICONDUCTORS DIV  14433    CAGE 14433  
100A330-2E - Replace Reference Number8 - Replacement NSNLOCKHEED MARTIN CORPORATION  03640    CAGE 03640  
SN5451AJE - Replace Reference Number8 - Replacement NSNTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN5451J00E - Replace Reference Number8 - Replacement NSNTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
MPD20709AJE - Replace Reference Number8 - Replacement NSNTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
7451DCQCE - Replace Reference Number8 - Replacement NSNFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
3520045-1E - Replace Reference Number8 - Replacement NSNNORTHROP GRUMMAN SYSTEMS CORPORATION  92755    CAGE 92755  
US7451AE - Replace Reference Number8 - Replacement NSNSPRAGUE ELECTRIC CO  13606    CAGE 13606  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

E - Replace Reference Number

Reference Number Category Code (DRN_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

8 - Replacement NSN

Reference Number Variation Code (DRN_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.


FLIS - SEG A - IDENTIFICATION | NSN 5962-00-369-7831 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962003697831A458A031779X1QNBA03 Mar 1974
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

003697831

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-00-369-7831

A458A0

Federal Item Identification Guide (FIIG_4065)

31779

Item Naming Code (INC_4080)

3 Mar 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5962-00-369-7831 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
B031001 Apr 1991
G86000C1 Apr 1991
G88000C1 Apr 1991
ZC011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZN011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
YB011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZW011 Nov 1998
ZB011 Apr 2000
YA011 Aug 2000
WP011 Mar 2005
A918A1961TZCDBDCTCLBF1 Aug 2006
MC49MC131TZPA1 Aug 2006
N9BNN9ND1TZKEGTKEJBHD1 Aug 2006
S911S0071TZXN1 Aug 2006
BGX1BTX11T1 Aug 2006
C911C0071T1 Aug 2006
FXGXFXTX1TZSX1 Aug 2006
ZU011 Apr 2008
ZX011 Nov 2013
YS011 Feb 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

T

Acquisition Method Suffix Code (AMSC_2876)


Acquisition of this part is controlled by QPL procedures. Valid AMCs: 1 and 2.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

PA

Item Management Coding Activity (IMC_ACTY_2748)


Marine Corps Logistics Base, Albany, GA 31704-1128

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

XN

Item Management Coding Activity (IMC_ACTY_2748)


National Security Agency, ATTN: L111, Fort George G. Meade, MD 20755-6000

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

JBCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

BD

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

CT

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

BF

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000


FLIS - SEG C - REFERENCE NUMBER | NSN 5962-00-369-7831 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
22EZZM38510/00502BCA  81349   CAGE/81349
4413TXDMIL-M-38510/5  81349   CAGE/81349
3523ZGD28578-01051  K0662   CAGE/K0662
4523ZGBW5083098CM  S3092   CAGE/S3092
3593ZGDW5083098CM  S3118   CAGE/S3118
459ETXBM38510/00502BCB  81349   CAGE/81349
59EZZBM38510/00502BCX  81349   CAGE/81349
1593TXBDM7451N  27014   CAGE/27014
4C15TUDSD19796A  27014   CAGE/27014
C16TXAWP106074-51M  34309  
C16ZZAC9S6033-11  46859   CAGE/46859
C15TXAW122-7451  50621  
C15SBAW025707F  52542   CAGE/52542
C16ZZAC2885040-5B  53711   CAGE/53711
1C1448BAH3-12522-213-38  55209  
C16ZZAC10053-0  56481  
C16ZZAC37654822-001  80378   CAGE/80378
C16ZZACJANM38510-00502BCX  81349   CAGE/81349
C16ZZACJM38510-00502BCB  81349   CAGE/81349
C16ZZACM38510-05025CD  81349   CAGE/81349
C16ZZACM38510/00502CCB  81349   CAGE/81349
C16ZZACMIL-M-38510  81349   CAGE/81349
C16ZZACSNC5451J  81349   CAGE/81349
C16ZZAC5509415G29  90348  
C15TXAF058-002193  26916   CAGE/26916
C16ZZAC7903788-02  90536   CAGE/90536
1C1548B116979-002  91417   CAGE/91417
C15TXAF310095P1  94117   CAGE/94117
C15TXAF99000014-001  94580   CAGE/94580
C16ZZAC351-7694-012  94987   CAGE/94987
C16TXA5P161-5451  95542   CAGE/95542
1C1548A538904-2  96214   CAGE/96214
C16ZZACSN5451J  96214   CAGE/96214
C16ZZAC128C821H10  97942   CAGE/97942
C16TXAW581R500H95  97942   CAGE/97942
4C11TXDAW3214006-001-536  99696   CAGE/99696
C16ZZAC373715-1  00752   CAGE/00752
4C11SBDAW389332/1  00752   CAGE/00752
4C15TXDAW5451  01295   CAGE/01295
C15TXAW5451J  01295   CAGE/01295
4C13TXDAW7451  01295   CAGE/01295
3C13TXDSN23904  01295   CAGE/01295
4C15TXDAWSN23904J  01295   CAGE/01295
1C13TXDSN5451J-10  01295   CAGE/01295
C16ZZACSN5451S17  01295   CAGE/01295
C16ZZACSN6081N  01295   CAGE/01295
4C13TXDAWSN7451AN  01295   CAGE/01295
4C19TUBSN7451J00  01295   CAGE/01295
4C13TXDA5SN7451N-00  01295   CAGE/01295
1C13TXDSNM5451J  01295   CAGE/01295
C16ZZACWC5451  01295   CAGE/01295
C16ZZAC51NW9615A44  04713   CAGE/04713
4C16TXDA5SC5086PK  04713   CAGE/04713
4C11TXDAW4005013-402  07187   CAGE/07187
C15TXAF5451DM  07263   CAGE/07263
C16ZZAC7451DCQB  07263   CAGE/07263
4C16TXDAWDM7451J  12040   CAGE/12040
4C15TXDAW351-7694-010  13499   CAGE/13499
4C15TUD5451D  13499   CAGE/13499
C16ZZACNC5335  14433   CAGE/14433
E84XGN7451A  18324   CAGE/18324
E83TXN7451N  18324   CAGE/18324
3E85ZZDRC5451F  18324   CAGE/18324
3E85ZZDS5451A  18324   CAGE/18324
3E82ZZD2131619-1  19315   CAGE/19315
E86XGUS7451A  13606   CAGE/13606
3E85ZZB7451J883C  14433   CAGE/14433
4E85ZZD7451DCQC  07263   CAGE/07263
3E85ZZDMC5451L  04713   CAGE/04713
3E85ZZDMC7451LB4  04713   CAGE/04713
E86XGMC7451P  04713   CAGE/04713
E8ATX100A330-2  03640   CAGE/03640
3E85ZZDSN5451J00  01295   CAGE/01295
E86TXSN5451AJ  01295   CAGE/01295
E86TXMPD20709AJ  01295   CAGE/01295
E82XG3520045-1  92755   CAGE/92755
E85TX0310095P001  94117   CAGE/94117
3E82ZZD7903788-01  90536   CAGE/90536
Code Definitions

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

AC

Service / Agency Designator Code (SADC_4672)


Navy

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

A5

Service / Agency Designator Code (SADC_4672)


Navy / Defense Logistics Agency

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

E

Reference Number Category Code (RNCC_2910)


Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

8

Reference Number Variation Code (RNVC_4780)


A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.

XG

Reference Number Action Activity Code (RNAAC_2900)


USCG Engineering Logistics Center, Baltimore, MD 21226-5000

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5962-00-369-7831 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
BTX03TX15 Sep 1974 5962000092240 7 Oct 1988
BTX03TX110 Apr 1979 5962001111286 7 Oct 1988
BTX03TX110 Apr 1979 5962002451617 7 Oct 1988
BTX03TX15 Oct 1980 5962004210113 7 Oct 1988
BTX03TX110 Apr 1979 5962004718622 7 Oct 1988
BTX03TX116 Dec 1977 5962004779460 7 Oct 1988
BTX03TX11 Apr 1996 5962010030849 7 Oct 1988
BTX03TX116 Mar 1988 5962010359368 7 Oct 1988
BTX03TX123 Nov 1985 5962011036203 7 Oct 1988
BTX03TX17 Dec 1985 5962011069071 7 Oct 1988
BTX03TX03 Mar 1997 5962011884149 7 Oct 1988
BTX03TX111 Dec 1995 5962012130827 7 Oct 1988
Code Definitions

B

Item Standardization Code (ISC_2650)


A new item authorized for procurement, contained in a new or revised superseding specification or standard, that replaces prior items.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

3

Replaced / Replacement Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

1

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.

5 Sep 1974

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

10 Apr 1979

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5 Oct 1980

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

16 Dec 1977

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

1 Apr 1996

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

16 Mar 1988

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

23 Nov 1985

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

7 Dec 1985

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

3 Mar 1997

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

11 Dec 1995

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5962-00-009-2240

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-00-111-1286

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-00-245-1617

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-00-421-0113

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-00-471-8622

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-00-477-9460

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-003-0849

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-035-9368

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-103-6203

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-106-9071

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-188-4149

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

5962-01-213-0827

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

7 Oct 1988

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5962-00-369-7831 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TXP72D39AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

P

Less Than Carload (LCL_CD_2760)


77.5

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5962-00-369-7831 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSDU1ZEA0
DFSMSDU1NEA0
DMSMSDU1ZEA0
DNSMSDU1EA0
DSSMSDU1NEA0
GPSMSDU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5962-00-369-7831 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPGX1AAA0.2 lbs0.017 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD3ZZQQUM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.2 lbs

Unit Pack Weight (UP_WT_5153)

0.017 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

ZZ

Special Marking Code (SP_MKG_CD_5169)


Special requirements

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-00-369-7831 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.140 INCHES MINIMUM AND 0.185 INCHES MAXIMUM
ADAQBody Length0.796 INCHES MAXIMUM
ADATBody Width0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
CTFTCase Outline Source And DesignatorD-1 MIL-M-38510
CSSLDesign Function And Quantity4 GATE, AND-OR INVERT
CBBLFeatures ProvidedHERMETICALLY SEALED AND MONOLITHIC AND POSITIVE OUTPUTS
AEHXMaximum Power Dissipation Rating204.0 MILLIWATTS
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQWXOutput Logic FormTRANSISTOR-TRANSISTOR LOGIC
CQSZInclosure ConfigurationDUAL-IN-LINE
CQSJInclosure MaterialCERAMIC AND GLASS
CQZPInput Circuit PatternDUAL 2 WIDE 2 INPUT
CZENVoltage Rating And Type Per Characteristic-1.5 VOLTS MINIMUM POWER SOURCE AND 5.5 VOLTS MAXIMUM POWER SOURCE
ZZZKSpecification/Standard Data81349-MIL-M-38510/5A GOVERNMENT SPECIFICATION
AFJQStorage Temp Range-65.0/+150.0 DEG CELSIUS
CWSGTerminal Surface TreatmentSOLDER
TTQYTerminal Type And Quantity14 PRINTED CIRCUIT
TESTTest Data Document81349-MIL-M-38510 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top
Back to Top