Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
ML4324/BCA | 3 - Design Control Reference | 2 - Production Item | LANSDALE SEMICONDUCTOR, INC. | 58625 | ![]() |
4324/BCAJC | 3 - Design Control Reference | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
4324/BCBJC | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
SC26746LBR | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324BCJC | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324L | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324LB2 | 5 - Replaced / Discontinued | 9 - No Longer Used | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
61814197-001 | 5 - Replaced / Discontinued | 9 - No Longer Used | LOCKHEED MARTIN CORPORATION | 04939 | ![]() |
4030259-424 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 07187 | ![]() |
4324/BCBJC | C - Advisory Reference | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
SM-A-945034 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | ![]() |
SM-A-945034 | C - Advisory Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | ![]() |
7849814P001 | C - Advisory Reference | 1 - Incomplete Part Number | LOCKHEED MARTIN CORPORATION | 03538 | ![]() |
G390475-1 | C - Advisory Reference | 1 - Incomplete Part Number | EXELIS INC. | 24930 | ![]() |
MC38510-4324BCBS | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324BCXS | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324DCBS | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
5189205 | C - Advisory Reference | 1 - Incomplete Part Number | NAVAL SEA SYSTEMS COMMAND | 53711 | ![]() |
MC4324/BCBJC | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324/BCBJC | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324BCBS | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
MC4324BCBS | C - Advisory Reference | 1 - Incomplete Part Number | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
4324/BCBJC | C - Advisory Reference | 1 - Incomplete Part Number | TEXAS INSTRUMENTS INCORPORATED | 01295 | ![]() |
4324/BCBJC | C - Advisory Reference | 1 - Incomplete Part Number | TEXAS INSTRUMENTS INCORPORATED | 01295 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492096-218 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
G492296-1 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON COMPANY | 49956 | ![]() |
73-25107-001 | C - Advisory Reference | 1 - Incomplete Part Number | RAYTHEON E-SYSTEMS INC | 33875 | ![]() |
DMS 82067B | E - Replace Reference Number | 8 - Replacement NSN | DLA LAND AND MARITIME | 16236 | ![]() |
MC38510/4324DCBS | E - Replace Reference Number | 8 - Replacement NSN | FREESCALE SEMICONDUCTOR, INC. | 04713 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5962 | 010089563 | A458A0 | 31779 | X | 4 | 9 | Q | N | B | A | 0 | 1 Sep 1975 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZN01 | 1 Aug 1995 | |||||||||||||||||||||||||||||
ZS01 | 1 Sep 1995 | |||||||||||||||||||||||||||||
ZT01 | 1 Jan 1996 | |||||||||||||||||||||||||||||
YA01 | 1 Dec 2001 | |||||||||||||||||||||||||||||
WP01 | 1 Sep 2003 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
FXGX | FXTX | 3 | C | Z | SX | 1 Aug 2006 | ||||||||||||||||||||||||
MC49 | MC13 | 3 | C | Z | PA | 1 Aug 2006 | ||||||||||||||||||||||||
N9BN | N9ND | 3 | C | Z | HD | GT | JB | HD | 1 Aug 2006 | |||||||||||||||||||||
ZU01 | 1 Apr 2008 | |||||||||||||||||||||||||||||
YK01 | 1 Jan 2015 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 3 | ZZ | ML4324/BCA | 58625 | ![]() | ||||||
3 | 9 | E | TX | 4324/BCAJC | 04713 | ![]() | ||||||
5 | 9 | E | TX | B | 4324/BCBJC | 04713 | ![]() | |||||
5 | 9 | 5 | TX | B | MC4324L | 04713 | ![]() | |||||
1 | 5 | 9 | 3 | TX | B | MC4324LB2 | 04713 | ![]() | ||||
5 | 9 | 6 | TX | SC26746LBR | 04713 | ![]() | ||||||
5 | 9 | 5 | TX | B | 61814197-001 | 04939 | ![]() | |||||
5 | 9 | 5 | TX | B | 4030259-424 | 07187 | ![]() | |||||
4 | 5 | 9 | 3 | TX | B | MC4324BCJC | 04713 | ![]() | ||||
4 | C | 1 | 9 | TU | B | MC4324BCXS | 04713 | ![]() | ||||
C | 1 | 6 | ZZ | AC | MC4324DCBS | 04713 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AW | SM-A-945034 | 80063 | ![]() | |||
C | 1 | 6 | ZZ | AC | 4324/BCBJC | 81349 | ![]() | |||||
C | 1 | 6 | ZZ | AC | G390475-1 | 24930 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 73-25107-001 | 33875 | ![]() | |||||
C | 1 | 5 | ZZ | TX | G492096-218 | 49956 | ![]() | |||||
C | 1 | 6 | ZZ | AC | G492296-1 | 49956 | ![]() | |||||
C | 1 | 6 | ZZ | AC | 5189205 | 53711 | ![]() | |||||
C | 1 | 6 | ZZ | AC | MC38510-4324BCBS | 04713 | ![]() | |||||
C | 1 | 5 | TX | A5 | 4324/BCBJC | 01295 | ![]() | |||||
C | 1 | 5 | TX | AF | 7849814P001 | 03538 | ![]() | |||||
C | 1 | 6 | TX | AW | MC4324/BCBJC | 04713 | ![]() | |||||
4 | C | 1 | 5 | TX | D | AO | MC4324BCBS | 04713 | ![]() | |||
4 | E | 8 | 3 | TX | D | MC38510/4324DCBS | 04713 | ![]() | ||||
4 | E | 8 | 9 | TX | D | DMS 82067B | 16236 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
USA
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is of the type for which an indication of document availability is not required.
AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094
Navy
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Air Force / Defense Logistics Agency
Army / Air Force / Navy / Other DoD / Federal Aviation Administration / Other Civil Agencies
Navy / Defense Logistics Agency
Defense Logistics Agency
Army / Defense Logistics Agency
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | TX | 0 | 3 | TX | 0 | 4 Oct 1985 | 5962010806494 | 7 Feb 1984 |
1 | TX | 0 | 3 | TX | 1 | 4 Oct 1985 | 5962011135783 | 7 Feb 1984 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. See volume 4, chapter 4.9.Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.Represents an item for which a U.S. activity proposed cancelled-invalid or cancelled-use action or that the NIIN Status Code be changed to 9, and one or more NATO/FC did not concur in the proposal. Item is restricted to North Atlantic Treaty Organization/foreign country (NATO/FC) use only.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | P | 72D | 3 | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
77.5
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | V | U | 1 | Z | EA | 0 | |
DF | SMS | Z | U | 1 | N | EA | 0 | |
DM | SMS | Z | U | 1 | Z | EA | 0 | |
DN | SMS | Z | U | 1 | EA | 0 | ||
DS | SMS | Z | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | GX | 1 | AAA | 5.0 lbs | 0.670 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | D3 | ZZ | Q | Q | 6 | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Special requirements
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 3.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ADAU | Body Height | 0.140 INCHES MINIMUM AND 0.180 INCHES MAXIMUM |
ADAQ | Body Length | 0.660 INCHES MINIMUM AND 0.785 INCHES MAXIMUM |
ADAT | Body Width | 0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM |
CTFT | Case Outline Source And Designator | T0-116 JOINT ELECTRON DEVICE ENGINEERING COUNCIL |
CSSL | Design Function And Quantity | 2 MULTIVIBRATOR, VOLTAGE CONTROLLED |
CBBL | Features Provided | MONOLITHIC AND HERMETICALLY SEALED AND POSITIVE OUTPUTS AND W/BUFFERED OUTPUT |
AEHX | Maximum Power Dissipation Rating | 150.0 MILLIWATTS |
AFGA | Operating Temp Range | -55.0/+125.0 DEG CELSIUS |
CQWX | Output Logic Form | TRANSISTOR-TRANSISTOR LOGIC |
CQSZ | Inclosure Configuration | DUAL-IN-LINE |
CQSJ | Inclosure Material | CERAMIC AND GLASS |
CQZP | Input Circuit Pattern | DUAL 3 INPUT |
AFJQ | Storage Temp Range | -65.0/+150.0 DEG CELSIUS |
TEST | Test Data Document | 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |