5962-01-068-9593

MICROCIRCUIT,DIGITAL


5962-01-068-9593 (5962010689593, 010689593)
Part Numbers (54 listings): M38510/30605BCB | MIL-M-38510/306 | 74LS164 | 250-0066 | 639-462 | 644-571 | 369-462 | 305-018 | M38510-30605BCX | JANM38510/30605BCX | M38510/30605BEX | 10135955 | JM38510/30605BCB | 54LS164/BCAJC | 74LS164DCQC | 380-10028-149 | 34031046-001 | S161-54LS164 | 404068-24 | 01-49419-17 | M50-102 | 106660-01 | 477-1410-001 | 000-8002-838 | 7117572-1 | 7102674-016 | 51057-0068 | 51057-0028 | 51NW9615F41 | 54LS164/BCBJC | SN54LS164J | 507624-35 | 4050318-10 | 838816-0052 | 360388 | SN54LS164J883B | 4037969-605 | 7100260-1 | 313115P1 | 0N270546 | 7906169-01 | 58139-92019-28 | 74LS164N | 54LS164J | 54LS164J/883B | SN74LS164N8 | SN74LS164N-02 | SN74LS164 | SN74LS164J-00 | SNJ54LS164AJ | 1004854-01 | 019056002 | 54LS164DM | 54LS164DMQB |
Summary

FSG 59 / FSC 5962

DEMIL: Q

DEMIL INT: 3

HMIC: N

Date Created: 6 Dec 1978

Unit Weight: 10.0 lbs

Unit Size:

Unit Pack Cube: None

Replacement NSN:

5962-01-238-5519

Replacement Date: 6 Feb 1991

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-01-068-9593 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
M38510/30605BCB2 - Definitive Specification or Standard Document2 - Production ItemMILITARY SPECIFICATIONS  81349    CAGE 81349  
MIL-M-38510/3064 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
74LS1645 - Replaced / Discontinued2 - Production ItemFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
74LS1645 - Replaced / Discontinued2 - Production ItemALPHAMERIC SOLUTIONS LIMITED  U3816      
250-00665 - Replaced / Discontinued2 - Production ItemKEPCO, INC.  85604    CAGE 85604  
639-4625 - Replaced / Discontinued2 - Production ItemRS COMPONENTS LIMITED  K2504      
644-5715 - Replaced / Discontinued2 - Production ItemRS COMPONENTS LIMITED  K2504      
369-4625 - Replaced / Discontinued2 - Production ItemRS COMPONENTS LIMITED  K2504      
305-0185 - Replaced / Discontinued2 - Production ItemRS COMPONENTS LIMITED  K2504      
M38510-30605BCX5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
JANM38510/30605BCX5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
M38510/30605BEX5 - Replaced / Discontinued9 - No Longer UsedMILITARY SPECIFICATIONS  81349    CAGE 81349  
101359556 - Informative Reference9 - No Longer UsedPAEAEESIKUNTA  A486G      
JM38510/30605BCBC - Advisory Reference1 - Incomplete Part NumberMILITARY SPECIFICATIONS  81349    CAGE 81349  
54LS164/BCAJCC - Advisory Reference1 - Incomplete Part NumberUSM CORP  00613      
74LS164DCQCC - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
380-10028-149C - Advisory Reference1 - Incomplete Part NumberTHE BOEING COMPANY  82918    CAGE 82918  
34031046-001C - Advisory Reference1 - Incomplete Part NumberSYPRIS ELECTRONICS, LLC  28009    CAGE 28009  
34031046-001C - Advisory Reference1 - Incomplete Part NumberSYPRIS ELECTRONICS, LLC  28009    CAGE 28009  
S161-54LS164C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  95542    CAGE 95542  
S161-54LS164C - Advisory Reference1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  95542    CAGE 95542  
404068-24C - Advisory Reference1 - Incomplete Part NumberCARDION INC  12909    CAGE 12909  
01-49419-17C - Advisory Reference1 - Incomplete Part NumberCOMPUTER AUTOMATION INC  53908      
M50-102C - Advisory Reference1 - Incomplete Part NumberMILTOPE CORPORATION  54418    CAGE 54418  
106660-01C - Advisory Reference1 - Incomplete Part NumberROLM CORP  14345    CAGE 14345  
477-1410-001C - Advisory Reference1 - Incomplete Part NumberBOEING COMPANY, THE  94756    CAGE 94756  
000-8002-838C - Advisory Reference1 - Incomplete Part NumberBOEING COMPANY, THE  94756    CAGE 94756  
7117572-1C - Advisory Reference1 - Incomplete Part NumberLITTON SYSTEMS INC  17863    CAGE 17863  
7102674-016C - Advisory Reference1 - Incomplete Part NumberGE AVIATION SYSTEMS LLC  93322    CAGE 93322  
7102674-016C - Advisory Reference1 - Incomplete Part NumberGE AVIATION SYSTEMS LLC  93322    CAGE 93322  
51057-0068C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
51057-0068C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
51057-0028C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  27914    CAGE 27914  
51NW9615F41C - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
54LS164/BCBJCC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
SN54LS164JC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
SN54LS164JC - Advisory Reference1 - Incomplete Part NumberFREESCALE SEMICONDUCTOR, INC.  04713    CAGE 04713  
507624-35C - Advisory Reference1 - Incomplete Part NumberEDO CORPORATION  00752    CAGE 00752  
4050318-10C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  58960      
4050318-10C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC  58960      
838816-0052C - Advisory Reference1 - Incomplete Part NumberLITTON SYSTEMS INC. DIV NAVIGATION  13973    CAGE 13973  
838816-0052C - Advisory Reference1 - Incomplete Part NumberLITTON SYSTEMS INC. DIV NAVIGATION  13973    CAGE 13973  
360388C - Advisory Reference1 - Incomplete Part NumberCALIFORNIA INSTRUMENTS CORP  16067      
SN54LS164JC - Advisory Reference1 - Incomplete Part NumberADVANCED MICRO DEVICES, INC.  34335    CAGE 34335  
SN54LS164J883BC - Advisory Reference1 - Incomplete Part NumberADVANCED MICRO DEVICES, INC.  34335    CAGE 34335  
4037969-605C - Advisory Reference1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  07187    CAGE 07187  
7100260-1C - Advisory Reference1 - Incomplete Part NumberELECTRODYNAMICS, INC.  10236    CAGE 10236  
313115P1C - Advisory Reference1 - Incomplete Part NumberBAE SYSTEMS INFORMATION AND  94117    CAGE 94117  
0N270546C - Advisory Reference1 - Incomplete Part NumberNATIONAL SECURITY AGENCY  98230    CAGE 98230  
7906169-01C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  90536    CAGE 90536  
7906169-01C - Advisory Reference1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  90536    CAGE 90536  
58139-92019-28C - Advisory Reference1 - Incomplete Part NumberAAI CORPORATION  97384    CAGE 97384  
58139-92019-28C - Advisory Reference1 - Incomplete Part NumberAAI CORPORATION  97384    CAGE 97384  
74LS164C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
74LS164C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
74LS164NC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
74LS164NC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
54LS164JC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
54LS164J/883BC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN54LS164J883BC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164N8C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164N8C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164N-02C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164N-02C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164J-00C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SN74LS164J-00C - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SNJ54LS164AJC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
SNJ54LS164AJC - Advisory Reference1 - Incomplete Part NumberTEXAS INSTRUMENTS INCORPORATED  01295    CAGE 01295  
1004854-01C - Advisory Reference1 - Incomplete Part NumberRAYTHEON TECHNICAL SERVICES COMPANY  36378    CAGE 36378  
1004854-01C - Advisory Reference1 - Incomplete Part NumberRAYTHEON TECHNICAL SERVICES COMPANY  36378    CAGE 36378  
019056002C - Advisory Reference1 - Incomplete Part NumberSERVO CORPORATION OF AMERICA  92110    CAGE 92110  
54LS164DMC - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
54LS164DMQBC - Advisory Reference1 - Incomplete Part NumberFAIRCHILD SEMICONDUCTOR CORP  07263    CAGE 07263  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

6 - Informative Reference

Reference Number Category Code (DRN_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5962-01-068-9593 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962010689593A458A031779X1QNBA06 Dec 1978
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

010689593

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-01-068-9593

A458A0

Federal Item Identification Guide (FIIG_4065)

31779

Item Naming Code (INC_4080)

6 Dec 1978

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

Q

Demilitarization Code (DEMIL_CD_0167)


CCLI — Commerce Control List Item Demilitarization not required. CCLI are dual-use (military, commercial, and other strategic uses) items under the jurisdiction of the Bureau of Export Administration, U.S. Department of Commerce, through the Export Administration Regulations. The types of items under the Commerce Control List (CCL) are commodities (i.e., equipment, materials, electronics, propulsion systems, etc.), software, and technology. The CCL does not include those items exclusively controlled by another department or agency of the U.S. Government.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5962-01-068-9593 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G86000C1 Apr 1991
G90000L1 Apr 1991
YB011 Apr 1991
YJ011 Apr 1991
ZA011 Apr 1991
ZE011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZK011 Apr 1991
ZN011 Apr 1991
ZR011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
YW011 Mar 1995
ZW011 Dec 1995
WZ011 Oct 2003
WB011 Feb 2005
ZU011 Aug 2005
ZB011 Mar 2006
YA011 Nov 2008
ZX011 Aug 2009
ZP011 Jun 2010
WF011 Apr 2011
WL011 Jan 2012
YC011 Jul 2015
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG C - REFERENCE NUMBER | NSN 5962-01-068-9593 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
422ETXDM38510/30605BCB  81349   CAGE/81349
441ETXDMIL-M-38510/306  81349   CAGE/81349
5259ZD250-0066  85604   CAGE/85604
45269ZD305-018  K2504  
5269Z369-462  K2504  
5269Z639-462  K2504  
5269Z644-571  K2504  
1522ZKD74LS164  U3816  
5259ZD74LS164  07263   CAGE/07263
4593TXBM38510-30605BCX  81349   CAGE/81349
59ETXBM38510/30605BEX  81349   CAGE/81349
59ETXBJANM38510/30605BCX  81349   CAGE/81349
4699WFB10135955  A486G  
C15TXAF380-10028-149  82918   CAGE/82918
4C16TXDAFJM38510/30605BCB  81349   CAGE/81349
C15SBAW7906169-01  90536   CAGE/90536
1C1548BAH019056002  92110   CAGE/92110
4C11TXDAW7102674-016  93322   CAGE/93322
C15TXAF313115P1  94117   CAGE/94117
C15TXAF000-8002-838  94756   CAGE/94756
C15TXAF477-1410-001  94756   CAGE/94756
C15TXAWS161-54LS164  95542   CAGE/95542
C15TXAW58139-92019-28  97384   CAGE/97384
C1ATXAF0N270546  98230   CAGE/98230
C15TXAF74LS164DCQC  07263   CAGE/07263
C1548AH7100260-1  10236   CAGE/10236
C1548AH404068-24  12909   CAGE/12909
4C11TXDBB838816-0052  13973   CAGE/13973
C15TXAF106660-01  14345   CAGE/14345
C15TXAF360388  16067  
C15TXAF7117572-1  17863   CAGE/17863
1C1548BAH51057-0028  27914   CAGE/27914
C16TXAW51057-0068  27914   CAGE/27914
C1ETXA534031046-001  28009   CAGE/28009
C16TXAFSN54LS164J  34335   CAGE/34335
C16TXAFSN54LS164J883B  34335   CAGE/34335
C15TUAW1004854-01  36378   CAGE/36378
C1548AH01-49419-17  53908  
C15TXAFM50-102  54418   CAGE/54418
C15TXAW4050318-10  58960  
C16TXAF54LS164/BCAJC  00613  
C1548AH507624-35  00752   CAGE/00752
C15TXAF54LS164J  01295   CAGE/01295
C15TXAF54LS164J/883B  01295   CAGE/01295
4C15TXDAW74LS164  01295   CAGE/01295
C15TXA574LS164N  01295   CAGE/01295
C1548AHSN54LS164J883B  01295   CAGE/01295
C16TXA5SN74LS164  01295   CAGE/01295
C16TXAWSN74LS164J-00  01295   CAGE/01295
4C16TXDAWSN74LS164N-02  01295   CAGE/01295
C15TXAWSN74LS164N8  01295   CAGE/01295
4C13TXDAWSNJ54LS164AJ  01295   CAGE/01295
C1548AH51NW9615F41  04713   CAGE/04713
C15TXAF54LS164/BCBJC  04713   CAGE/04713
C16TXAWSN54LS164J  04713   CAGE/04713
C15TXAF4037969-605  07187   CAGE/07187
C15TX1AF54LS164DM  07263   CAGE/07263
C15TXAF54LS164DMQB  07263   CAGE/07263
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZK

Reference Number Action Activity Code (RNAAC_2900)


United Kingdom

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

6

Reference Number Category Code (RNCC_2910)


Informative Reference. North Atlantic Treaty Organization (NATO) Stock Numbers (CAGE Code 99995), Production Equipment Codes (CAGE 99998), and DoD Ammunition Codes (CAGE Code 99999) which may be related to NSNs. (Reference numbers for the CAGE Codes cited above shall be coded RNVC 9.)

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

WF

Reference Number Action Activity Code (RNAAC_2900)


Finland

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

AF

Service / Agency Designator Code (SADC_4672)


Defense Logistics Agency

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

AW

Service / Agency Designator Code (SADC_4672)


Air Force / Defense Logistics Agency

48

Reference Number Action Activity Code (RNAAC_2900)


Federal Aviation Administration, Oklahoma City, OK 73125

AH

Service / Agency Designator Code (SADC_4672)


Federal Aviation Administration

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

BB

Service / Agency Designator Code (SADC_4672)


Marine Corps / Defense Logistics Agency

A5

Service / Agency Designator Code (SADC_4672)


Navy / Defense Logistics Agency

TU

Reference Number Action Activity Code (RNAAC_2900)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

1

Reference Number Justification Code (RNJC_2750)


Technical data on the possible duplicated Federal Item Identification have been reviewed, and the additional items of production (reference numbers) are not acceptable for the item of supply.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5962-01-068-9593 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3TX01TX06 Feb 1991 5962012385519 17 Apr 2012
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

6 Feb 1991

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

5962-01-238-5519

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

17 Apr 2012

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5962-01-068-9593 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TX72D39AHZW061700Z34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

TX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43218

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5962-01-068-9593 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNS9EYU0EA0
Code Definitions

S9E

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


DLA Land and Maritime, Columbus, OH 43218 ** No longer valid for input **

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 5962-01-068-9593 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APGX110.0 lbs
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00X39M
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

10.0 lbs

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-01-068-9593 Submit RFQ
MRCDecoded RequirementClear Text Reply
ADAUBody Height0.140 INCHES MINIMUM AND 0.185 INCHES MAXIMUM
ADAQBody Length0.785 INCHES MAXIMUM
ADATBody Width0.220 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
CTFTCase Outline Source And DesignatorD-1 MIL-M-38510
CSSLDesign Function And Quantity1 SHIFT REGISTER, SERIAL IN, PARALLEL OUT
CBBLFeatures ProvidedHERMETICALLY SEALED AND MONOLITHIC AND POSITIVE OUTPUTS AND LOW POWER AND SCHOTTKY AND ASYNCHRONOUS AND W/BUFFERED OUTPUT AND W/CLEAR AND W/ENABLE AND RESETTABLE
AEHXMaximum Power Dissipation Rating149.0 MILLIWATTS
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQWXOutput Logic FormTRANSISTOR-TRANSISTOR LOGIC
CQSZInclosure ConfigurationDUAL-IN-LINE
CQSJInclosure MaterialCERAMIC AND GLASS
CQZPInput Circuit Pattern4 INPUT
CZEQTime Rating Per Chacteristic48.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, LOW TO HIGH LEVEL OUTPUT AND 56.00 NANOSECONDS MAXIMUM PROPAGATION DELAY TIME, HIGH TO LOW LEVEL OUTPUT
CZENVoltage Rating And Type Per Characteristic-0.5 VOLTS MINIMUM POWER SOURCE AND 7.0 VOLTS MAXIMUM POWER SOURCE
ZZZKSpecification/Standard Data81349-MIL-M-38510/306 GOVERNMENT SPECIFICATION
AFJQStorage Temp Range-65.0/+150.0 DEG CELSIUS
CWSGTerminal Surface TreatmentSOLDER
TTQYTerminal Type And Quantity14 PRINTED CIRCUIT
TESTTest Data Document81349-MIL-M-38510 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Back to Top