5962-01-366-5692

MICROCIRCUIT,LINEAR


5962-01-366-5692 (5962013665692, 013665692)
Part Numbers (5 listings): 5962-8972801EA | 5962-89728 | AD588SD/883B | 5962-8972801EB | 5962-8972801EX |
Summary

FSG 59 / FSC 5962

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 28 Oct 1992

Unit Weight: None

Unit Size: None

Unit Pack Cube: None

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-01-366-5692 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
5962-8972801EA2 - Definitive Specification or Standard Document2 - Production ItemDLA LAND AND MARITIME  67268    CAGE 67268  
5962-897284 - Non-Definitive Specification or Standard Document1 - Incomplete Part NumberDLA LAND AND MARITIME  67268    CAGE 67268  
AD588SD/883B5 - Replaced / Discontinued1 - Incomplete Part NumberANALOG DEVICES, INC.  24355    CAGE 24355  
5962-8972801EB5 - Replaced / Discontinued9 - No Longer UsedDLA LAND AND MARITIME  67268    CAGE 67268  
5962-8972801EX5 - Replaced / Discontinued9 - No Longer UsedDLA LAND AND MARITIME  67268    CAGE 67268  
Code Definitions

2 - Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

4 - Non-Definitive Specification or Standard Document

Reference Number Category Code (DRN_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5962-01-366-5692 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962013665692A458A031778X1DNBA028 Oct 1992
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

013665692

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-01-366-5692

A458A0

Federal Item Identification Guide (FIIG_4065)

31778

Item Naming Code (INC_4080)

28 Oct 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

B

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with ESD sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5962-01-366-5692 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZG011 Jan 2002
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5962-01-366-5692 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
22ETX5962-8972801EA  67268   CAGE/67268
41ETX5962-89728  67268   CAGE/67268
51ETXAD588SD/883B  24355   CAGE/24355
59ETXB5962-8972801EB  67268   CAGE/67268
59ETXB5962-8972801EX  67268   CAGE/67268
Code Definitions

2

Reference Number Category Code (RNCC_2910)


Definitive Government Specification or Standard Designator Reference. A part number, style number, or type designator included in or developed in accordance with a Government specification or standard which has the effect of fully identifying an item of supply. This code shall also be used for a Government specification or standard which, although not including part numbers, style numbers, or type designators, covers a single item of upply. These reference numbers may be coded with Reference Number Variation Code (RNVC) 1 in accordance with volume 2, paragraph 2.9.2.n.(4).

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

4

Reference Number Category Code (RNCC_2910)


Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5962-01-366-5692 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TX011 Nov 1995
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Nov 1995

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5962-01-366-5692 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TH
Code Definitions

TH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43215

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5962-01-366-5692 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPGX1AAA
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XD339QQM
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

Unit Pack Weight (UP_WT_5153)

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Intermediate Container Code (INTMD_CTNR_CD_5167)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-01-366-5692 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationEO LOROPS E/I FSCM 72314
CTFTCase Outline Source And DesignatorD-2 MIL-M-38510
CSSLDesign Function And Quantity4 REFERENCE, VOLTAGE, ANALOG
CBBLFeatures ProvidedPROGRAMMABLE
AEHXMaximum Power Dissipation Rating600.0 MILLIWATTS
ZZZTNondefinitive Spec/Std Data01 TYPE AND E CASE
AFGAOperating Temp Range-55.0/+125.0 DEG CELSIUS
CQSZInclosure ConfigurationDUAL-IN-LINE
CQSJInclosure MaterialCERAMIC
CXCYPart Name Assigned By Controlling AgencyMICROCIRCUIT,LINEAR,PRECISION VOLTAGE REFERENCE,MONOLITHIC SILICON
CZENVoltage Rating And Type Per Characteristic-18.0 VOLTS MINIMUM ABSOLUTE INPUT AND 18.0 VOLTS MAXIMUM ABSOLUTE INPUT
ZZZKSpecification/Standard Data67268-5962-89728 GOVERNMENT STANDARD
AFJQStorage Temp Range-65.0/+150.0 DEG CELSIUS
CWSGTerminal Surface TreatmentSOLDER
TTQYTerminal Type And Quantity16 PRINTED CIRCUIT
TESTTest Data Document81349-MIL-M-38510 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND 96906-MIL-STD-883 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). AND 96906-MIL-BUL-103 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Back to Top