5962-01-648-8238

MICROCIRCUIT,MEMORY


5962-01-648-8238 (5962016488238, 016488238)
Part Number (1 listing): 497156-B88
Summary

FSG 59 / FSC 5962

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 8 Oct 2015

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5962-01-648-8238 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
497156-B883 - Design Control Reference2 - Production ItemHEWLETT PACKARD CO  28480    CAGE 28480  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5962-01-648-8238 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595962016488238A458A041015X43ANAA48 Oct 2015
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5962

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Microcircuits, Electronic

016488238

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5962-01-648-8238

A458A0

Federal Item Identification Guide (FIIG_4065)

41015

Item Naming Code (INC_4080)

8 Oct 2015

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

4

ADPE Identification Code (ADPEC_0801)


ADP Input/Output and Storage Devices Used to Control and Transfer Information to and from a CPU. The input device is used for transferring data and instructions into a CPU. The output device is used to transfer results of processing by the CPU onto printed forms, punched cards, and/or magnetic media. Input/output devices combine the above functions in the same device. This class also includes data transmission terminals, batch terminals, and display terminals which are specially designed or modified to be used in conjunction with digital, analog, or hybrid CPUs. It includes modems when they are integral to the terminal. It also includes storage devices in which data can be inserted, retained, and retrieved for later use.


FLIS - SEG B - MOE RULE DATA | NSN 5962-01-648-8238 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Oct 2015
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5962-01-648-8238 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD497156-B88  28480   CAGE/28480
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5962-01-648-8238 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

ET

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5962-01-648-8238 Submit RFQ
MRCDecoded RequirementClear Text Reply
CZZZMemory Capacity1GB
CZERMemory Device TypeRAM
CQSZInclosure ConfigurationDUAL-IN-LINE
CXCYPart Name Assigned By Controlling AgencyHP 1GB DDR3 1333MHZ 240 PIN DIMM MEMORY MODULE
TTQYTerminal Type And Quantity240 PIN


Back to Top