Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
BFT196-36-59-830 | 3 - Design Control Reference | 9 - No Longer Used | CETEC CORP | 23427 | ![]() |
G30030 | 5 - Replaced / Discontinued | 9 - No Longer Used | TRIUMPH MFG CO | 78806 | ![]() |
W20E060X0-22 | 5 - Replaced / Discontinued | 9 - No Longer Used | PERMOFLUX DIV OF DX RADIO AND TV | 77196 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5965 | 001708675 | A06400 | 00362 | X | M | 9 | A | P | U | 1 Jan 1961 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Oct 2009 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | D3 | 0 | 6 Sep 1971 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
U.S. Army Communications Electronics, Fort Monmouth, NJ 07703-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M | 658 | Z | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI | 1 |
85
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ABMZ | Diameter | 2.279 INCHES NOMINAL |
HGTH | Height | 0.876 INCHES NOMINAL |
AGAZ | Noise Canceling Feature | NOT INCLUDED |
AFZA | Output Sensitivity Rating In Decibels | -56.0 |
AFZB | Output Sensitivity Rating Reference | 1 VOLT PER MICROBAR |
AFYW | Frequency Response Range In Hertz | +200.0 TO 3500.0 |
AFYY | Impedance Rating | 240.0 KILOHMS NOMINAL |
AGAX | Polarity Connection | NOT REQUIRED |
AGBC | Shock Mount | NOT PROVIDED |
AGAY | Sound Pickup Directional Type | UNIDIRECTIONAL |
AGBA | Support Stand | NOT INCLUDED |