Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
FOM7 MONO | 3 - Design Control Reference | 9 - No Longer Used | OPTOACOUSTICS LTD | SEK76 | ![]() |
FOM7 MONO | C - Advisory Reference | 1 - Incomplete Part Number | OPTOACOUSTICS LTD | 2518A | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5965 | 016281874 | A545Q0 | 68603 | X | 4 | 3 | C | P | A | A | 0 | 13 May 2014 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A102 | 0 | 0 | 0 | E | CN | 1 May 2014 | ||||||||||||||||||||||||
F8SQ | 0 | 0 | 0 | E | CN | 1 May 2014 | ||||||||||||||||||||||||
MS22 | 0 | 0 | 0 | E | CN | 1 May 2014 | ||||||||||||||||||||||||
NJQ4 | 0 | 0 | 0 | E | CN | 1 May 2014 | ||||||||||||||||||||||||
SC01 | 0 | 0 | P | E | CN | 1 May 2014 |
Not Established
DLIS File Conversion Code. This code was assigned by DLIS to existing wholesale interservice supply support agreement (WISSA) type recording (LOA 8D) during initial file conversion program. This code is reassigned to code 1, 2, 3, 5, 6 or 8 upon completion of item review. The SICA CMD will reflect the SOS/SOSM and AAC compatible with the PICA. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Total depot maintenance is being accomplished by commercial contract.
Contract, Contiguous United States (CONUS)
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 5 | ZZ | FOM7 MONO | SEK76 | ![]() | ||||||
C | 1 | 5 | ZZ | 9F | FOM7 MONO | 2518A | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
CAGE Status Change
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 13 May 2014 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XJ |
HQ USSOCOM, MacDill AFB, FL 33621-5323
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | H9D | J | 7 | 1 | L | KT | 0 | |
DF | H9D | J | 7 | 1 | U | KT | 0 | |
DJ | H9D | J | 7 | 1 | KT | 0 | ||
DM | H9D | J | 7 | 1 | L | KT | 0 | |
DN | H9D | J | 7 | 1 | H | KT | 0 |
Special Operations Forces Support Activity (SOFSA), BLDG 220, 5749 Briar Hill Rd, Lexington, KY 40516-9721
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
1
ARMY: Disposal is not authorized below wholesale/specialized repair activity level; MARINE CORPS: Reparable item. Repair, condemnation, and disposal not authorized below depot/specialized repair activity level; NAVY: Local stock items or items pending national stock number assignment
Kit - A collection of related items issued as a single item of supply, such as the tools, instruments, repair parts, instruction sheets and often supplies typically carried in a box or bag. Also includes selected collections of equipment components, tools, and/or materials for the repair, overhaul or modification of equipment. Use only when the term “kit” is a part of the item name.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC NF2: AF Equipment Management System (AFEMS); NAVY: Fast moving centrally managed 1I COG forms (locally procured at selected designated overseas activities)
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Department of the Army
Department of the Air Force
HQ United States Special Operations Command (HQ USSOCOM)
U.S. Marine Corps
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
FEAT | Special Features | FOM7 MONO KIT IS A MINIATURE OPTICAL MICROPHONE FOR ACOUSTIC MONITORING. CONSISTS OF A CASE, FOM7 MONO ELECTRONIC BOX W/O INTERNAL RECORDER & DSP EOU250, 2 FIBER OPTIC CABLES AND MICROPHONES, HEADPHONE, AUDIO CABLE. DC POWER SUPPLY, 9V BATTERY AND QUICK GUIDE. H9D/SOCOM LOGISTICS HELP DESK: CML (859)293-3114; DSN: 745-3114; TOLL FREE: 888-763-7259; EMAIL: LOGISTICSHELPDESK@SOFSA.MIL |