Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
342A124-5 | 3 - Design Control Reference | 2 - Production Item | TYCO ELECTRONICS CORPORATION | 06090 | ![]() |
13030378-1 | 7 - Vendor Item Drawing Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5970 | 000603959 | A22500 | 61626 | X | K | A | P | A | 10 Jun 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZX01 | 1 Nov 2003 | |||||||||||||||||||||||||||||
DGX1 | DCX1 | 5 | H | CX | 1 Aug 2004 | |||||||||||||||||||||||||
ZF01 | 1 May 2015 |
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Defense Supply Center Richmond, Richmond, VA 23297-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 1 | CX | D | 342A124-5 | 06090 | ![]() | ||||
7 | 2 | 2 | 9Z | D | 13030378-1 | 18876 | ![]() |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
DLIS-K, Battle Creek, MI 49037-3084
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 31 Mar 1971 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 72D | Z | 9 | A | H | Z | W | 103300 | Z | 53360 | INSULATING-MATERIAL-NOI |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAG | Distance From Edge Of Main Body To Intersecting Centerlines | 1.840 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAA | Distance From Intersecting Centerline Of Main Body To End Of First Branch | 1.680 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | Angle Between Main Body And First Branch Centerlines In Deg | 15.0 NOMINAL AS SUPPLIED |
AGAQ | Angle Between Main Body And First Branch Centerlines In Deg | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES | Color | BLACK |
UKBG | Dielectric Material Voltage Rating Per Unit Thickness | 200.0 VOLTS PER MIL /0.001 INCH/ |
ADZC | Environmental Protection | FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZV | First Branch Inside Diameter | 0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | First Branch Inside Diameter | 0.520 INCHES MINIMUM AS SUPPLIED |
AGAC | First Branch Wall Thickness | 0.060 INCHES MAXIMUM AS SUPPLIED |
AGAC | First Branch Wall Thickness | 0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
FLEX | Flexibility | FLEXIBLE |
MATT | Material | RUBBER,NEOPRENE,RT-501,RAYCHEM CORP |
CQBC | Minimum Tensile Strength | 1500 POUNDS PER SQUARE INCH |
AGAB | Main Body Wall Thickness | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAB | Main Body Wall Thickness | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AFZU | Main Body Inside Diameter | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZU | Main Body Inside Diameter | 1.060 INCHES MINIMUM AS SUPPLIED |
AGAH | Main Body Overall Length | 3.500 INCHES MAXIMUM AS SUPPLIED |
AGAH | Main Body Overall Length | 3.540 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AARG | Reliability Indicator | NOT ESTABLISHED |
STYL | Style Designator | TRANSITION-45 DEGREES |
ABJH | Temp Rating | -55.0 DEG CELSIUS |