5970-00-071-0564

INSULATOR,PINCAP


5970-00-071-0564 (5970000710564, 000710564)
Part Number (1 listing): 9080
Summary

FSG 59 / FSC 5970

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5970-00-071-0564 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
90803 - Design Control Reference1 - Incomplete Part NumberLAPP INSULATOR COMPANY LLC  75539      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5970-00-071-0564 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595970000710564A007A000224X1APU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5970

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Insulators and Insulating Materials

000710564

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5970-00-071-0564

A007A0

Federal Item Identification Guide (FIIG_4065)

00224

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5970-00-071-0564 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G90000L1 Apr 1991
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

L

Acquisition Advice Code (AAC_2507)


LOCAL PURCHASE (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5970-00-071-0564 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX013 Dec 1980
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Dec 1980

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5970-00-071-0564 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5970-00-071-0564 Submit RFQ
MRCDecoded RequirementClear Text Reply
STYLStyle DesignatorMUSHROOM
ABKVOutside Diameter16.000 INCHES NOMINAL
ABKWOverall Height14.000 INCHES NOMINAL
ABTBMounting Hole Diameter0.688 INCHES NOMINAL
AFFLMounting Bolt Circle Diameter5.000 INCHES NOMINAL
AGEUBase Diameter6.000 INCHES NOMINAL
AJQLTop Diameter6.250 INCHES NOMINAL
CRFBCenter To Center Distance Between Dome Holes5.000 INCHES NOMINAL
MTLCMaterial And LocationOVERALL PORCELAIN
STLCSurface Treatment And LocationOVERALL GLAZED
AAPCIdentification Code ColorBROWN
AXHRMounting Facility Type And Quantity2 UNTHREADED HOLE
CQBPScrew Thread Series Designator And LocationELECTRICAL TERMINATION UNC
CRFLScrew Thread Diameter And Location0.500 ELECTRICAL TERMINATION INCHES NOMINAL
CQTPScrew Thread Quantity Per Inch And Location13 ELECTRICAL TERMINATION
CRPGThread Class And Location2A ELECTRICAL TERMINATION
TMQYFurnished Items And Quantity2 BOLTS 5/8-11 THD BY 1.250 IN. LG AND WASHERS


Back to Top
Back to Top