5970-00-119-0903

INSULATOR,BUSHING


5970-00-119-0903 (5970001190903, 001190903)
Part Numbers (2 listings): 10556506 | 1240001190903 |
Summary

FSG 59 / FSC 5970

DEMIL: B

DEMIL INT:

HMIC: P

Date Created: 16 Oct 1968

Unit Weight: 1.0 lbs

Unit Size: 3.7in x 4.3in x 0.6in

Unit Pack Cube: 5.000 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5970-00-119-0903 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
105565063 - Design Control Reference2 - Production ItemUS ARMY ARDEC RDECOM  19200    CAGE 19200  
12400011909035 - Replaced / Discontinued9 - No Longer UsedE.C.A ETABLISSEMENT  SCY13      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5970-00-119-0903 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595970001190903A007A018301NKBPA016 Oct 1968
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5970

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Insulators and Insulating Materials

001190903

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5970-00-119-0903

A007A0

Federal Item Identification Guide (FIIG_4065)

18301

Item Naming Code (INC_4080)

16 Oct 1968

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5970-00-119-0903 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YJ011 Apr 1991
ZH011 Apr 1991
ZU011 Apr 1991
ZA011 Oct 1993
ZP011 Apr 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5970-00-119-0903 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3321BFD10556506  19200   CAGE/19200
4599YPB1240001190903  SCY13  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

BF

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

9

Document Availability Code (DAC_2640)


The reference number is of the type for which an indication of document availability is not required.

YP

Reference Number Action Activity Code (RNAAC_2900)


Morocco

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5970-00-119-0903 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6BF022 Jan 1969
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

BF

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 Jan 1969

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5970-00-119-0903 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
BGP658Z9AHZP061300X34410CIRCUIT-BREAKER-SWITCH-NOI1
Code Definitions

BG

Originating Activity Code (ORIG_ACTY_CD_4210)


RDECOM-ECBC-RI Rock Island, IL 61299

P

Less Than Carload (LCL_CD_2760)


77.5

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

061300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34410

Uniform Freight Classification (UFC_CD_MODF_3040)

CIRCUIT-BREAKER-SWITCH-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 5970-00-119-0903 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAB14VU1ZEA0
DAB14VU1EA0
DMB14V71ZEA0
Code Definitions

B14

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Armament and Chemical Acquisition and Logistics, Activity, ATTN: AMSTA-AC, Rock Island, IL 61299-6000

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps


FLIS - SEG W - PACKAGING DATA | NSN 5970-00-119-0903 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APBZZZ1.0 lbs3.7in x 4.3in x 0.6in5.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZ
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

B

Item Type Storage Code (ITM_TYP_STOR_5156)


Unheated General Purpose

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

1.0 lbs

Unit Pack Weight (UP_WT_5153)

3.7in x 4.3in x 0.6in

Unit Pack Size (UP_SZ_5154)

5.000 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5970-00-119-0903 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationPERISCOPE F10541951
CFNTFirst Counterbore Depth0.156 INCHES NOMINAL
BXCZFirst Counterbore Diameter1.281 INCHES NOMINAL
AAPCIdentification Code ColorRED AND WHITE
ABKVOutside Diameter1.368 INCHES NOMINAL
AARXInside Diameter1.108 INCHES NOMINAL
MTLCMaterial And LocationOVERALL PLASTIC, ACRYLONITRILE-BUTADIENE-STYRENE ERR-100 ERR-100 ELECTRICAL TERMINATION COPPER ERR-100 ERR-100
ABKWOverall Height0.500 INCHES NOMINAL
STYLStyle DesignatorCYLINDRICAL
STLCSurface Treatment And LocationELECTRICAL TERMINATION SOLDER COATED ERR-100 ERR-100


Back to Top
Back to Top