INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE


5970-00-134-5360 (5970001345360, 001345360)
Part Numbers (2 listings): 562A043-5 | 11154184-4 |
Summary

FSG 59 / FSC 5970

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 12 May 1969

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5970-00-134-5360 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
562A043-53 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  06090    CAGE 06090  
11154184-47 - Vendor Item Drawing Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5970-00-134-5360 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595970001345360A2250061626X1APA12 May 1969
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5970

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Insulators and Insulating Materials

001345360

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5970-00-134-5360

A22500

Federal Item Identification Guide (FIIG_4065)

61626

Item Naming Code (INC_4080)

12 May 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5970-00-134-5360 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZZ
FXGG3CZSX1 Aug 2004
A9183CZBD1 Dec 2004
N9BG3CZGHGG1 Dec 2013
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

BD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

GGCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 5970-00-134-5360 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325CX562A043-5  06090   CAGE/06090
3721CXD11154184-4  18876   CAGE/18876
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5970-00-134-5360 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
BD72DZ9AHZW103300Z53360INSULATING-MATERIAL-NOI
Code Definitions

BD

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

103300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

53360

Uniform Freight Classification (UFC_CD_MODF_3040)

INSULATING-MATERIAL-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5970-00-134-5360 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZU1ZEA0
DFSMSZU1NEA0
DNSMSZU1EA0
DSSMSZU1NEA0
DASMSZU1ZEA0
DFSMSZU1NEA0
DNSMSZU1EA0
DSSMSZU1NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5970-00-134-5360 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAGDistance From Edge Of Main Body To Intersecting Centerlines2.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAADistance From Intersecting Centerline Of Main Body To End Of First Branch1.770 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AFZZDistance From Intersecting Centerline Of Main Body To End Of Second Branch1.940 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAQAngle Between Main Body And First Branch Centerlines In Deg10.0 NOMINAL AS SUPPLIED
AGAQAngle Between Main Body And First Branch Centerlines In Deg45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
AGARAngle Between Main Body And Second Branch Centerlines In Deg15.0 NOMINAL AFTER UNRESTRICTED RECOVERY
AGARAngle Between Main Body And Second Branch Centerlines In Deg10.0 NOMINAL AS SUPPLIED
HUESColorBLACK
UKBGDielectric Material Voltage Rating Per Unit Thickness200.0 VOLTS PER MIL /0.001 INCH/
ADZCEnvironmental ProtectionFLAME RESISTANT AND MILDEW RESISTANT
AFZVFirst Branch Inside Diameter0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZVFirst Branch Inside Diameter0.520 INCHES MINIMUM AS SUPPLIED
AGACFirst Branch Wall Thickness0.060 INCHES MAXIMUM AS SUPPLIED
AGACFirst Branch Wall Thickness0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXFlexibilityFLEXIBLE
AFZYFourth Branch Inside Diameter0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZYFourth Branch Inside Diameter0.520 INCHES MINIMUM AS SUPPLIED
AGAFFourth Branch Wall Thickness0.060 INCHES MAXIMUM AS SUPPLIED
AGAFFourth Branch Wall Thickness0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MATTMaterialRUBBER, NEOPRENE, RT-501, RAYCLAD TUBES INC
CQBCMinimum Tensile Strength1200 POUNDS PER SQUARE INCH
AGABMain Body Wall Thickness0.100 INCHES MAXIMUM AS SUPPLIED
AGABMain Body Wall Thickness0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AFZUMain Body Inside Diameter0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZUMain Body Inside Diameter1.060 INCHES MINIMUM AS SUPPLIED
AARGReliability IndicatorNOT ESTABLISHED
AFZWSecond Branch Inside Diameter0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZWSecond Branch Inside Diameter0.520 INCHES MINIMUM AS SUPPLIED
AGADSecond Branch Wall Thickness0.060 INCHES MAXIMUM AS SUPPLIED
AGADSecond Branch Wall Thickness0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
STYLStyle DesignatorTRANSITION-1 TO 4 CABLES
ABJHTemp Rating150.0 DEG CELSIUS
AFZXThird Branch Inside Diameter0.240 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZXThird Branch Inside Diameter0.520 INCHES MINIMUM AS SUPPLIED
AGAEThird Branch Wall Thickness0.060 INCHES MAXIMUM AS SUPPLIED
AGAEThird Branch Wall Thickness0.060 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY