5970-00-943-0968

INSULATION SLEEVING,ELECTRICAL,SPECIAL PURPOSE


5970-00-943-0968 (5970009430968, 009430968)
Part Numbers (18 listings): 382A034-3 | SS7073-1802 | GS830AE3-3 | 202-25212-3 | 0011591139 | 11176428-3 | 42013341EZ5052-81 | CP35-1-91-1-071 | C085105-003 | 33028-003 | 10041163-1 | 2503520-4 | 204-1-B7 | C195-Z14-C3 | GS83AE3-3 | SC5975-0024-48 | 493H145-1 | C5075979-11 |
Summary

FSG 59 / FSC 5970

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 21 Dec 1965

Unit Weight: 0.3 lbs

Unit Size: None

Unit Pack Cube: 0.022 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5970-00-943-0968 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
382A034-33 - Design Control Reference2 - Production ItemTYCO ELECTRONICS CORPORATION  06090    CAGE 06090  
382A034-35 - Replaced / Discontinued1 - Incomplete Part NumberTYCO ELECTRONICS RAYCHEM GMBH  D1973      
SS7073-18025 - Replaced / Discontinued1 - Incomplete Part NumberSIKORSKY AIRCRAFT CORPORATION  78286    CAGE 78286  
GS830AE3-35 - Replaced / Discontinued1 - Incomplete Part NumberNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
202-25212-35 - Replaced / Discontinued1 - Incomplete Part NumberTRIUMPH AEROSTRUCTURES, LLC  80378    CAGE 80378  
00115911395 - Replaced / Discontinued1 - Incomplete Part NumberDAIMLER AG  D8046    CAGE D8046  
11176428-35 - Replaced / Discontinued1 - Incomplete Part NumberBALLISTIC MISSILE DEFENSE SYSTEMS  17773    CAGE 17773  
42013341EZ5052-815 - Replaced / Discontinued1 - Incomplete Part NumberIVECO MAGIRUS AG  D8060      
CP35-1-91-1-0715 - Replaced / Discontinued1 - Incomplete Part NumberLOCKHEED MARTIN CORPORATION  25500    CAGE 25500  
C085105-0035 - Replaced / Discontinued1 - Incomplete Part NumberGYRODYNE CO OF AMERICA INC  10618      
33 028-0035 - Replaced / Discontinued1 - Incomplete Part NumberROCKWELL COLLINS DEUTSCHLAND GMBH  D9853      
10041163-15 - Replaced / Discontinued1 - Incomplete Part NumberU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
2503520-45 - Replaced / Discontinued1 - Incomplete Part NumberHONEYWELL INTERNATIONAL INC.  07187    CAGE 07187  
204-1-B75 - Replaced / Discontinued1 - Incomplete Part NumberHELLERMANNTYTON LIMITED  K0720      
C195-Z14-C35 - Replaced / Discontinued2 - Production ItemSIEMENS SCHWEIZ AG  S3120      
GS83AE3-35 - Replaced / Discontinued9 - No Longer UsedNORTHROP GRUMMAN SYSTEMS CORPORATION  26512    CAGE 26512  
SC5975-0024-485 - Replaced / Discontinued9 - No Longer UsedDRS ICAS, LLC  12115    CAGE 12115  
493H145-15 - Replaced / Discontinued9 - No Longer Used3M CO ADMININISTRATIVE ELECTRONIC &  20999    CAGE 20999  
C5075979-117 - Vendor Item Drawing Reference1 - Incomplete Part NumberSIGNALS WARFARE PROJECT MANAGER  57958      
493H145-1C - Advisory Reference1 - Incomplete Part Number3M COMPANY  53387    CAGE 53387  
493H145-1C - Advisory Reference1 - Incomplete Part Number3M COMPANY  53387    CAGE 53387  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5970-00-943-0968 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595970009430968A2250061626XKAPA21 Dec 1965
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5970

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Insulators and Insulating Materials

009430968

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5970-00-943-0968

A22500

Federal Item Identification Guide (FIIG_4065)

61626

Item Naming Code (INC_4080)

21 Dec 1965

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5970-00-943-0968 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
G86000C1 Apr 1991
YB011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
ZH011 Apr 1991
ZN011 Apr 1991
ZP011 Apr 1991
ZS011 Apr 1991
ZT011 Apr 1991
ZA011 Jul 2002
FXGGFXCX3DZSX1 May 2005
N9BGN9GD3DZKEGTKEHXHD1 May 2005
A918A1783DZCDCL1 May 2005
ZW011 Nov 2005
ZU011 Apr 2008
C9203D1 Jul 2009
WP011 Jun 2011
YD011 Sep 2016
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

C

Acquisition Advice Code (AAC_2507)


SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

D

Acquisition Method Suffix Code (AMSC_2876)


The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111

HXCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Navy ICP, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

CL

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006


FLIS - SEG C - REFERENCE NUMBER | NSN 5970-00-943-0968 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4321CXD382A034-3  06090   CAGE/06090
15129ZD2503520-4  07187   CAGE/07187
3512CXDC085105-003  10618  
15129ZDCP35-1-91-1-071  25500   CAGE/25500
51ACXGS830AE3-3  26512   CAGE/26512
4515CXDSS7073-1802  78286   CAGE/78286
1515CXD202-25212-3  80378   CAGE/80378
3513ZGD382A034-3  D1973  
4513ZGA0011591139  D8046   CAGE/D8046
4516ZGD42013341EZ5052-81  D8060  
4513ZGB33 028-003  D9853  
45169ZD204-1-B7  K0720  
3511BDD10041163-1  18876   CAGE/18876
4526ZGAC195-Z14-C3  S3120  
59ACXBGS83AE3-3  26512   CAGE/26512
595SBBSC5975-0024-48  12115   CAGE/12115
595CXB493H145-1  20999   CAGE/20999
71ACXC5075979-11  57958  
C15ZZD9F493H145-1  53387   CAGE/53387
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

1

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZG

Reference Number Action Activity Code (RNAAC_2900)


Germany

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

BD

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

9F

Service / Agency Designator Code (SADC_4672)


CAGE Status Change


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5970-00-943-0968 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX031 Mar 1971
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

31 Mar 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5970-00-943-0968 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CX72DZ9AHZW103300Z53360INSULATING-MATERIAL-NOI
Code Definitions

CX

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Richmond, Richmond, VA 23297-5000

72D

Water Commodity Code (WRT_CMDTY_CD_9275)


Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

103300

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

53360

Uniform Freight Classification (UFC_CD_MODF_3040)

INSULATING-MATERIAL-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5970-00-943-0968 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSDU1ZEA0
DFSMSDU1NEA0
DNSMSDU1EA0
DSSMSDU1NEA0
GPSMSDU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

D

Acquisition Advice Code (AAC_2507)


DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency

GP

Service / Agency Code (MOE_CD_2833)


U.S. Coast Guard


FLIS - SEG W - PACKAGING DATA | NSN 5970-00-943-0968 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP101AAA0.3 lbs0.022 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00CAXD300EQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

10

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Physical protection

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.3 lbs

Unit Pack Weight (UP_WT_5153)

0.022 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

CA

Wrapping Material Code (WRAP_MAT_CD_5163)


A-A-203, kraft wrapping paper

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5970-00-943-0968 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAGDistance From Edge Of Main Body To Intersecting Centerlines2.580 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGAADistance From Intersecting Centerline Of Main Body To End Of First Branch3.220 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AGARAngle Between Main Body And Second Branch Centerlines In Deg22.5 NOMINAL AFTER UNRESTRICTED RECOVERY
AGARAngle Between Main Body And Second Branch Centerlines In Deg10.0 NOMINAL AS SUPPLIED
HUESColorBLACK
UKBGDielectric Material Voltage Rating Per Unit Thickness200.0 VOLTS PER MIL /0.001 INCH/
ADZCEnvironmental ProtectionCORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
AFZVFirst Branch Inside Diameter0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZVFirst Branch Inside Diameter1.060 INCHES MINIMUM AS SUPPLIED
AGACFirst Branch Wall Thickness0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FLEXFlexibilitySEMIRIGID
MATTMaterialPLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP OR PLASTIC,POLYOLEFIN,MPP-262,3M CO
CQBCMinimum Tensile Strength1500 POUNDS PER SQUARE INCH
AGABMain Body Wall Thickness0.120 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
AFZUMain Body Inside Diameter0.710 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZUMain Body Inside Diameter1.520 INCHES MINIMUM AS SUPPLIED
AARGReliability IndicatorNOT ESTABLISHED
AFZWSecond Branch Inside Diameter0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
AFZWSecond Branch Inside Diameter1.060 INCHES MINIMUM AS SUPPLIED
AGADSecond Branch Wall Thickness0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FEATSpecial FeaturesADHESIVE COATING
STYLStyle DesignatorTRANSITION-Y
ABJHTemp Rating-55.0 DEG CELSIUS


Back to Top